MTL4852 MTL Safety Barrier Secondary Interface Module
|
MTL4852 Secondary Interface ModuleThe MTL4852 HART connection system provides a simple interface between smart devices in the field, control systems and HART instrument management software run on a pc . The system is based on 16-channel modularity to provide a compact, easily configurable and expandable system. Using a standard RS485 serial link up to 7936 HART devices can be connected on a single network. For the optimum solution, choose from a range of general purpose and IS termination boards. For maximum flexibility the HMM64 HART backplane locates an MTL4851 master communications module and up to three MTL4852 secondary interface modules, with each module connecting to 16 field devices. General purpose HART connection units and IS backplanes are available fitted with an cable interface connection to the HMM64. This system can be extended with further HMS64 HART backplanes linked to the master, each carrying up to four MTL4852 secondary interface modules . The MTL4852 modules can also be located on HTP- SC16x termination boards for general purpose applications. HART loops are simply wired through these HART Termination Panels and may be grounded or floating circuits. The HTP boards offer a compact and cost- effective solution for general applications. CPH-SC16x backplanes are ideal for signal loops requiring intrinsic safety (IS) protection, combining multiplexer and IS isolator mounting. This offers considerable simplification in wiring when compared to DIN-rail based solutions .
SPECIFICATION
Number of HART channels 16 (ch17 to ch256 in 16 channel groups) Channel device type HART rev 5-7 Channel interface 2 connections to each channel MTL systems interface Up to 15 off MTL4852 modules per MTL4851 Total length of interface bus, 4m max. Power requirements Powered from MTL4851 module ISOLATION Channel-to-channel isolation 50V dc Field loop isolation 50V dc Module is coupled to loops via capacitor in each connection leg (i.e. 2 capacitors per channel) RS485 interface isolation (Between module and interface) 50V dc Alarm output isolation (Between module and output) 50V dc PSU isolation (Between module and PSU input) 50V dc POWER SUPPLY, MTL4851 (from backplane) Supply voltage 19V to 35V dc Current consumption 42mA at 24V ±10% for MTL4851, plus 2mA for each MTL4852 Power dissipation (MTL4851 + 15 MTL4852) <1.6W at 24V ±10% PSU protection Reversed polarity protected
ENVIRONMENTAL Temperature range Operating: –40°C to +60°C Non-operating: –40°C to +85°C Relative humidity 5% to 95% - non-condensing MECHANICAL Dimensions See drawing Weight MTL4851 95gm MTL4852 75gm Approvals For the latest certificate information,see www.mtl-inst.com/certificates
Related Part Number:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: MTL4852 MTL Safety Barrier MTL Safety Barrier CE MTL4852 |
![]() |
MTL4544 Eaton-MTL Repeater Power Supply Safe-area Circuit Ripple 50µA Peak-to-Peak for Two-channel Industrial Applications |
![]() |
MTL7796- MTL Zener Barriers DIN Rail Mount DC Power Supply |
![]() |
MTL4573 MTL Temperature Converter for RTD Excitation Current 200µA Nominal Output Range 4 to 20mA Nominal into 600Ω Max |
![]() |
MTL4531 MTL Vibration Transducer Interface Signal Range -20V to 35V DC Durable and Long-Lasting |
![]() |
MTL CPS16 16-Way Backplane Screw-Clamp Connector Equipped with Electrical Connection Plug-in Connectors |
![]() |
Eaton Crouse-Hinds Series MTL HMS64/HMM64 Backplane 64 channel with 4 x MTL4852 capacity |