0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc
|
MTL5532 PULSE ISOLATORThe MTLx532 isolates pulses from a switch, proximity detector, current pulse transmitter or voltage pulse transmitter located in a hazardous area. It is ideal for applications involving high pulse rates and fast response times, by repeating the pulses into the safe area. An analogue output proportional to frequency is also provided, together with a relay output, which may be configured to act as an alarm. Configuration is carried out with a personal computer.
SPECIFICATION Number of channels One, fully floating Sensor type Switch or proximity detector (NAMUR/BS EN 60947–5–6:2001) 2– or 3–wire voltage or pulse transmitter Location of switch Zone 0, IIC, T6 hazardous area Div. 1, Group A, hazardous location Location of proximity detector or transmitter Zone 0, IIC, T4–T6 if suitably certified Div.1, Group A, hazardous location Input Switch input: Output ON if switch is closed Proximity detector input: Excitation: 7.0 to 9.0V dc from 1kΩ nominal Output ON if input > 2.1mA* (< 2kΩ) Output OFF if input < 1.2mA* (> 10kΩ) Switching hysteresis: 0.2mA (650Ω) nominal *NAMUR and BS EN 60947–5–6:2001standards Current pulse input: Transmitter supply: 16.5V dc at 20mA Short circuit current: 24mA Output: Iin > 9.0mA = ON, Iin < 7.0mA = OFF Switching hysteresis: 0.5mA Voltage pulse input Input impedance: > 10kΩ Switching point voltage (Vsp): 3, 6, or 12V nominal (User selectable by switches on the side of the module) Output: V in > Vsp = ON, Vin < Vsp = OFF Switching hysteresis: 100mV + (0.1 x Vsp) typical Safe-area pulse output Maximum delay: 10µs Maximum off–state voltage: 35V Maximum off–state leakage current: 10µA Maximum on–state resistance: 25Ω Maximum on–state current: 50mA Output OFF if supply fails Note: LFD signal is Zener-diode protected against inductive loads Safe-area current output Input capture delay: 2 signal periods (5ms min.) Signal range: 4 to 20mA Under/over range: 0 to 22mA Load resistance: 0 to 450Ω @20mA Output resistance: >1MΩ Ripple: < 50µA peak-to-peak Accuracy: better than 20µA at 20°C Temperature drift: < 1µA/°C Risetime (10% - 90%, after step change): 60 ms Alarm output Relay ON in alarm, 0.5A @ 35Vdc max. Pulse width High: 10µs min Low: 10µs min Frequency range 0 – 50kHz - pulse output mode 0 – 10KHz - for analogue output LED indicators Green: power indication Yellow: on when output circuit is on Red: flashing when line fault or error Power requirement 65mA at 24V dc 70mA at 20V dc 55mA at 35V dc Power dissipation within unit 1.35W maximum at 24V 1.75W maximum at 35V Safety description (Um = 253V rms or dc) Terminals 2 to 1 and 6 to 1 U =10.5V I =14mA P =37mW o o o Terminals 4 to 3 and 1 Uo =28V Io =93mA Po =651mW Terminals 3 to 1 Non-energy-storing apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected without further certification into any IS loop with an open- circuit voltage <28V Terminals 5 to 4 and 1 Vmax ≤ 28V, Imax ≤ 94mA, Pmax ≤ 0.66W Configurator A personal computer running MTL PCS45 software with a PCL45USB serial interface
Related Part Number:
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: 0.5A MTL Safety Barrier 50kHz MTL Safety Barrier MTL5532 pulse isolator 35Vdc |
![]() |
MTL4544 Eaton-MTL Repeater Power Supply Safe-area Circuit Ripple 50µA Peak-to-Peak for Two-channel Industrial Applications |
![]() |
MTL7796- MTL Zener Barriers DIN Rail Mount DC Power Supply |
![]() |
MTL4573 MTL Temperature Converter for RTD Excitation Current 200µA Nominal Output Range 4 to 20mA Nominal into 600Ω Max |
![]() |
MTL4531 MTL Vibration Transducer Interface Signal Range -20V to 35V DC Durable and Long-Lasting |
![]() |
MTL CPS16 16-Way Backplane Screw-Clamp Connector Equipped with Electrical Connection Plug-in Connectors |
![]() |
Eaton Crouse-Hinds Series MTL HMS64/HMM64 Backplane 64 channel with 4 x MTL4852 capacity |