MTL5511 Switch Proximity Detector Interface 25mA 24V
|
MTL5511 SWITCH/ PROXIMITY DETECTOR INTERFACEThe MTLx511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the line- fault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for the channel is selected by a switch on the side of the module and output is provided by changeover relay contacts.
SPECIFICATION Location of switches Zone 0, IIC, T6 hazardous area Div. 1, Group A hazardous location Location of proximity detector Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location Hazardous-area inputs Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR) Voltage applied to sensor 7 to 9V dc from 1kΩ ±10% Input/output characteristics Normal phase Outputs closed if input > 2.1mA (< 2kΩ in input circuit) Outputs open if input < 1.2mA (> 10kΩ in input circuit) Hysteresis: 200µA (650Ω) nominal Line fault detection (LFD) (when selected) User-selectable via switches on the side of the unit. A line fault is indicated by an LED. The channel output relay is de-energisedif an input line fault is detected. Open-circuit alarm on if Iin < 50µA Open-circuit alarm offif Iin > 250µA Short-circuit alarm on if Rin < 100Ω Note: Resistors must be fitted when using the LFD facility with a contact input 500Ω to 1kΩ in series with switch 20kΩ to 25kΩ in parallel with switch Safe-area output Single pole relay with changeover contacts Note: reactive loads must be adequately suppressed LED indicators Green: power indication Yellow: channel status, on when output energised Red: LFD indication, on when line fault detected Maximum current consumption 25mA at 24V Power dissipation within unit 0.6W at 24V
Related Part Number:
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: MTL Safety Barrier 25mA MTL Safety Barrier 25mA 24V MTL5511 |
![]() |
MTL4544 Eaton-MTL Repeater Power Supply Safe-area Circuit Ripple 50µA Peak-to-Peak for Two-channel Industrial Applications |
![]() |
MTL7796- MTL Zener Barriers DIN Rail Mount DC Power Supply |
![]() |
MTL4573 MTL Temperature Converter for RTD Excitation Current 200µA Nominal Output Range 4 to 20mA Nominal into 600Ω Max |
![]() |
MTL4531 MTL Vibration Transducer Interface Signal Range -20V to 35V DC Durable and Long-Lasting |
![]() |
MTL CPS16 16-Way Backplane Screw-Clamp Connector Equipped with Electrical Connection Plug-in Connectors |
![]() |
Eaton Crouse-Hinds Series MTL HMS64/HMM64 Backplane 64 channel with 4 x MTL4852 capacity |