Technical spec. | YC1893D-6 | YC1893D-12 | YC1893D-24 | YC1893D-48 |
Number of meter positions | 6 | 12 | 24 | 48 |
Accuracy | 0.05 / 0.02 |
Power Source | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
Standard Meter | SZ03A-K6 / SZ03A-K8 |
Scanning Head | YCG-S Series |
Voltage |
|
Test voltage output(Phase-Neutral) | 3x(24V~288V)(or customized) |
Power of the voltage output | Max. 3x100VA | Max. 3x250VA | Max. 3x500VA | Max. 3x1000VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.05% at the final range value |
Stability | Better than 0.005% /h (integration time 150s) |
Load regulation from 0~max. load | Better than 0.01% |
Distortion factor | Better than 0.3% for linear resistance load |
Harmonic | 2nd~21st free programmable |
Current |
|
Test current output | 3x(1mA~100A) |
Power of the current output | Max. 3x150VA | Max. 3x350VA | Max. 3x750VA | Max. 3x1500VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.05% at the final range value |
Stability | Better than 0.005% /h (integration time 150s) |
Load regulation from 0~max. load | Better than 0.01% |
Distortion factor | Better than 0.3% for linear resistance load |
Harmonic | 2nd~21st free programmable |
Phase angle |
|
Range | 0~360⁰ |
Resolution | 0.01⁰ |
Setting accuracy | 0.1⁰ |
Frequency |
|
Range | 45Hz~65Hz |
Resolution | 0.01Hz |
Error display |
|
Type of error display | Red LED |
Resolution of error displays | 8 digitals |
Other |
|
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz |
Ambient temperature | -10°C~+40°C |
Relative humidity | 35%~85% |