China Stationary Meter Test System manufacturer
Guangzhou GENY Electric Co., Ltd
Professional in Energy Meter Testing
3
Home > Products > Stationary Meter Test Bench >

Three Phase Stationary Meter Test Bench

Three Phase Stationary Meter Test Bench

Brand Name GENY
Model Number YC-1893D
Place of Origin CHINA
Certification ISO, CE
Minimum Order Quantity 1
Payment Terms L/C, D/P, T/T, D/A
Supply Ability 10 pcs/ 3 months
Delivery Time 8 ~10weeks
Packaging Details Plywood cases
Model no. YC1893D-24-0.02-F
Accuracy class 0.02%
Operation Temperature -10ºC--+40ºC
Humidity -35%--85%
Power of the current output 3×2000VA
Detailed Product Description

Professional Three-Phase Stationary Meter Test Bench for Electric Energy Meter Testing

Stationary Three Phase Meter Test Bench

 

 

The YC1893D meter test system is a full-automatic test system for testing and calibration of both single-phase and three-phase electric energy meters, which composes of:
 

  • Three-phase Power source
  • Three-phase Reference standard meter
  • Meter suspension test racks for testing of both 1-phase/3-phase meters
  • Smart meter function test system (fixed voltages, optical probe, relay control test and ripple control box as option)
  • Other necessary parts
  • PC and software controlling the whole system

 
The YC1893D meter test system is fully compliant with the IEC 60736 standard and is suitable for testing meters according to the following standards:

 

  • IEC 62052-11 and IEC 62053-11, -21, -22, -23, -24
  • IEC 62056
  • EN 50470-1, EN 50470-2, EN-50470-3
  • IEC 61010

 


Features

 

 

  • The meter test system can measure mechanical meters, electronic mechanical meters and electronic meter by the way of automatic, semi-automatic or manual operation.
  • Aluminium alloy material, light and strong and corrosion resistant.
  • Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.
  • The swing together of the scanning heads simplifies the control.
  • Fully automatic completion of the following tests:
    • Accuracy test in all four quadrants (active, reactive and apparent energy)
    • Repeatability of error test
    • Creep test (No-load test)
    • Starting current test
    • Dial test (Register test)
    • Meter constant test
    • Influence quantity test (voltage, voltage unbalance, frequency, harmonic distortion, reverse phase sequence.)
    • Calibration of reference standard meter having lower accuracy than the employed reference standard
    • Pre-warming
    • Dips and Interruptions
    • Testing single-phase meters under tampered conditions
    • Sub Harmonics as per IEC standards
    • Odd Harmonics as per IEC standards
  • Measuring different constants of meters synchronously.
  • With the protection function of overload, short voltage circuit and open current circuit.

 

Technical specification

 

 

 

The test bench is multiple positions up to 24 meters, 0.02% of accuracy class Three-phase Meter Test System with ICTs, with multiple serial port communication system for parallel communication for testing of smart meters.

 

  • Power Supply

 

 

Voltage3x230 / 400 V ±10%, 50 / 60 Hz ±2 Hz
Frequency50 Hz ±15%
Power capacity> 6 kVA
Power efficient(at full load)≥85%
Ambient temperature-10 °C -- +40 °C
Relative humidity35% - 85%
 

 

  • Power Source

 

 

Voltage
Test voltage output (Phase-Neutral)3x(24 – 300 V)
Power of the voltage output3×1000VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load< 0.01%
Distortion factor< 0.3% for linear resistance load
Harmonics2nd – 41st free programmable
Current
Test current output1 mA – 120 A
Power of the current output3×2000VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load< 0.01%
Distortion factor< 0.3% for linear resistance load
Harmonics2nd – 41st free programmable
Phase angle
Range0 -- 360°
Resolution0.01°
Setting accuracy0.1°
Frequency
Range45 Hz – 65 Hz
Resolution0.01 Hz
 

 

Structural diagram of stationary meter test bench

 
*If you want to know more please check our official website:http://www.genymetertestequipment.com/
 