China EV Charger Cable manufacturer
Linke Cable Technology (DongGuan) CO.,LTD
Linke Cable Technology (DongGuan) CO.,LTD
2
Home > Products > EV Charger Cable >

UL TUV Certified Fire Retardant Cable with PVC Sheath and XLPE Insulation

Browse Categories

Linke Cable Technology (DongGuan) CO.,LTD

City: dongguan

Province/State:guangdong

Country/Region:china

Tel:86-0769-81776230

Contact Person:
Mr.William Liu
View Contact Details

UL TUV Certified Fire Retardant Cable with PVC Sheath and XLPE Insulation

Certification UL;ISO9001;ISO13485;IATF16949;TPU
Model NO. FR-UL
Conductor Material Copper
Sheath Material PVC
Insulation Material XLPE
Material Shape Round Wire
Range of Application Flame Retardant
Brand Linke
Type 1 Fire Retardant Cable
Type 2 Wire
Type 3 Cable
Type 4 Electric Wire
Rated Temperature(ºC) 105c
Transport Package Roll
Specification 2.5SQ*3C+0.5SQ*1C
Trademark LINKE
Origin China
HS Code 8544492900
Supply Ability 50000m/day
Package Size 550.00cm * 550.00cm * 380.00cm
Package Gross Weight 25.000kg
Lead Time 7-15days
Type Insulated
Conductor Type Twisted wire
Application Overhead, Heating, Underground
Samples US$ 1000/PCS 1 PCS(Min.Order) |
Customization Available
Shipping Cost about shipping cost and estimated delivery time.
  Initial Payment Full Payment
Currency US$
Return&refunds You can apply for a refund up to 30 days after receipt of the products.
Place of Origin Guangdong, China
Brand Name Linke
Minimum Order Quantity 1000m
Price Negotiable
Packaging Details According to requirement
Delivery Time 7-15 days
Payment Terms Advance 30% deposit and ship after receiving 70% final payment
conductor material copper/Tinned Copper
Exterior material customize:PVC、PE、LSFOH、silicone rubber
insulating materials customize:PVC、PE 、XLPE、EPR、SIR
specifications 0.1-450mm²
rated voltage 300-600V
rated temperature -60± 200℃
colour customize
package By roll
Core Multiple
Detailed Product Description

PTFE/PVC/PFA/Fiberglass K Type Thermocouple Extension Compensation Wire Cable

Product Parameters

 

 he thermocouple compensation cables can also be termed as instrumentation cables, since they are used for

process temperature measurement. The construction is similar to pair instrumentation cable but the conductor

material is different. Thermocouples are used in processes to sense temperature and is connected to the pyrometers

for indication and control. The thermocouple and pyrometer are electrically conducted by thermocouple extension

cables / thermocouple compensating cables. The conductors used for these thermocouple cables are required to

have similar thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature.
Our mill mainly manufacture type KX,,EX,JX,TX,SC/RC,KCA,KCB  compensating wire for thermocouple,

and they are used in temperature measurement instruments and cables. Our thermocouple compensating products

are all made abiding by GB/T 4990-2010 'Alloy wires of extension and compensating cables for thermocouples'

(Chinese National Standard), and also IEC584-3 'Thermocouple part 3-compensating wire' (International standard).
The representing of the comp. wire: thermocouple code+C/X , e.g. SC, KX
X:  Short for extension, means that the compensation wire's alloy is as the same as the the alloy of the thermocouple
C:  Short for compensation, means that the compensation wire's alloy has similar characters with the thermocouple's alloy

in a certain temperature range.

Thermocouple CodeComp. TypeComp. Wire NamePositiveNegative
NameCodeNameCode
SSCcopper-constantan 0.6copperSPCconstantan 0.6SNC
RRCcopper-constantan 0.6copperRPCconstantan 0.6RNC
KKCAIron-constantan22IronKPCAconstantan22KNCA
KKCBcopper-constantan 40copperKPCBconstantan 40KNCB
KKXChromel10-NiSi3Chromel10KPXNiSi3KNX
NNCIron-constantan 18IronNPCconstantan 18NNC
NNXNiCr14Si-NiSi4MgNiCr14SiNPXNiSi4MgNNX
EEXNiCr10-Constantan45NiCr10EPXConstantan45ENX
JJXIron-constantan 45IronJPXconstantan 45JNX
TTXcopper-constantan 45 copperTPXconstantan 45 TNX

1. Chemical Composition

MaterialChemical composition (%)
NiCrSiMnAl
KP(Chromel)9010   
KN(Alumel)95 1-20.5-1.51-1.5

2. Physical properties and Mechnical properties

Material

Density(g/cm3)

Melting point(ºC)

Tensile Strength(Mpa)

Volume resistivity(μΩ.cm)

Elongation rate (%)

KP(Chromel)8.51427>49070.6(20ºC)>10
KN(Alumel)8.61399>39029.4(20ºC)>15

3. EMF Value range at different temperature

MaterialEMF value Vs Pt(μV)
100ºC200ºC300ºC400ºC500ºC600ºC
KP(Chromel)2816~28965938~60189298~937812729~1282116156~1626619532~19676
KN(Alumel)1218~12622140~21802849~28933600~36444403~44635271~5331
 
EMF value Vs Pt(μV)
700ºC800ºC900ºC1000ºC1100ºC
22845~2299926064~2624629223~2941132313~3252535336~35548
6167~62477080~71607959~80598807~89079617~9737

 

Type K Extension Cable Chromel / Alumel Material FEP insulation

Specifications

1.Style:Extension Wire
2.Thermocouple copper wire
Thermocouple copper wire Classification
1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple

type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.


2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating

cable and extension wire of various thermocouples of type S, R, B, K, E, J, T, N and L, heating cable, control cable and so on.

Thermocouple variety and index


Thermocouple Variety and Index

Variety

Type

Measurement Range(°C)

NiCr-NiSi

K

-200-1300

NiCr-CuNi

E

-200-900

Fe-CuNi

J

-40-750

Cu-CuNi

T

-200-350

NiCrSi-NiSi

N

-200-1300
NiCr-AuFe0.07NiCr-AuFe0.07
-270-0
 

3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire

 Dimensions / Tolerance mm ) : 4.0+-0.25

Color code & initial calibration tolerances for thermocouple wire:

Thermocouple TypeANSI Color CodeInitial Calibration Tolerances
Wire AlloysCalibration+/-
Conductor
JacketTemperature RangeStandard
Limits
Special
Limits
CHROMEL(+) vs.
ALUMEL(-)
KYellow/RedBrown-200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C
± 2%
±2.2°C
±2.2°C
± .75%
±1.1°C
± .4%


Color Code & Initial Calibration Tolerance for Extension Wire:

Extension typeANSI Color CodeInitial Calibration Tolerances
Wire AlloysCalibration+/-
Conductor
JacketTemperature RangeStandard
Limits
Special
Limits
Iron (+) vs. Constantan(-)JXWhite/RedBlack0°C to +200°C±2.2°C±1.1°C
CHROMEL (+) vs. ALUMEL (-)KXYellow/RedYellow0°C to +200°C±2.2°C±1.1°C
Copper(+) vs. Constantan(-)TXBlue/RedBlue-60°C to +100°C±1.1°C± .5°C
CHROMEL(+) vs. Constantan(-)EXPurple/RedPurple0°C to +200°C±1.7°C±1.1°C


PVC-PVC Physical Properties:

CharacteristicsInsulationJacket
Abrasion ResistanceGoodGood
Cut Through ResistanceGoodGood
Moisture ResistanceExcellentExcellent
Solder Iron ResistancePoorPoor
Service Temperature

105ºC continuous

150ºC single

105ºC continuous

150ºC single

Flame TestSelf-extinguishingSelf-extinguishing
 
 
Conductor : Flexible Bare annealed copper wire 
Insulation:Silicone
Choice of Black, Orange, Red or Yellow Blue jacket, single & double insulated.
SQ MM sizes (European style) :4 sq mm to 240 sq mm
AWG sizes (North American style) :0AWG-10AWG,
Wide temperature range: -60°C to 200°C 
 
 
2,Low viscosity appearance
Conductor : Flexible Bare annealed copper wire 
Insulation:Silicone
Choice of Black, Orange, Red or Yellow Blue jacket, single & double insulated.
SQ MM sizes (European style) :4 sq mm to 240 sq mm
AWG sizes (North American style) :0AWG-10AWG,
Wide temperature range: -60°C to 200°C 
 
Company Profile:

Wire and cable manufacturer Linke Cable Technology Co., Ltd is a leading cable supplier in China. In the past over 10 years,

Linke Cable has been focusing on R&D, production and marketing of wire and cable. Linke provide various cables&custom

cable solutions for all over the world. We are specialized in EV charging cable, medical cable, silicone cable, spring cable,

braided cable, towlobe cable, UL wire, automotive cable, etc.

At Linke cable, we believe there's a better way to bring better cables to market. We use an engineer-to-engineer approach

to develop better cables for customers and  improve the quality of one's life.
 

Our certification:

We past UL1007,UL1185,UL1672,UL10070,UL10483,UL1015,UL1569,UL10012,UL10269

(Single conductor,thermoplastic insulation)
UL2095,UL2129,UL2468,UL2586,UL2725,UL20233,UL20280,UL20963,UL2103,UL2463,UL2517,UL2587,

UL2835,UL20276,UL20549,UL21198,2104,UL2464,UL2576,UL2661,UL2919,UL20279,UL20886,UL21664

ISO9001 and ISO13485,TS16949

CNR- Appliance Wiring Material,

Extruded PVC Insulated Single,rated 105ºC,1000V,ClassI,GroupA,B,or AB, FT1 and/or FT2.

Extruded PVC Non-integral Jacketed Cable, rated 105"C, 1000V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2.

Extruded TPU Non-integral Jacketed Cable, rated 80"C, 300V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2

FAQ

1. Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first begining to the last. 

Welcome to visit us. We'll pick you up in Shenzhen.
 

2. How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.

 

3. What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy. 
You'd better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.

 

4. Can I get a discount?
It depends on your quantity, We can make a discount and afford the freight. Pls kindly contact us.

 

5. Does your company accept OEM production?
Yes, could print your company name, we even custom the quality card to promote your company

Product Tags: PVC Sheath Fire Retardant Cable   UL TUV Certified Fire Retardant Cable   XLPE Insulation Fire Retardant Cable  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Linke Cable Technology (DongGuan) CO.,LTD
Subject:
Message:
Characters Remaining: (80/3000)