Full spectrum measurement and DOAS (Differential Optical Absorption Spectroscopy) algorithm, excelling in accuracy, repeatability and anti-interference with moisture, dust. Modular design and no moving parts, higher reliability and easier maintenance. Pulse Xenon Lamp used as light source with over 10-year lifetime. The adoption of diode array sensor enables instant spectrum acquisition and rapid response.
>>> Measuring principle1) The light source emits ultraviolet beam which transfers to gas cell through optical fiber. 2) After absorption by measuring gas, the light beam transfers through optical fiber to spectrometer. 3) Being dispersed through the grating, and converted into electric signal by the array sensor, a continuous absorption spectrum of measuring gas is thereafter obtained.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Item | UV Hot-Wet Method | NDIR |
| Spectral Range | Complete and continuous absorption spectra obtained through holographic grating and diode array detection | Non Dispersive, characteristic absorption spectra obtained through band-pass filter |
| Linear Response | High wavelength resolution secures linear response | band-pass filtration compromises linear response |
| SO2 Loss | Hot-wet prohibits SO2 dissolution | Condensation inevitably causes SO2 loss |
| Sampling System | Heat tracing. Requests only dust filtration, simple and no corrosive | Cold-dry. Requests dust filtration, condensation, water removal and corrosion proof |
| Zero Calibration Period | Long (DOAS algorithm) | Short |
| Anti-Interference | The combination of complete & continuous absorption spectra, high wavelength resolution, DAOS algorithm erases interference from dust, moisture and background gases | Vulnerable to moisture interference |
| Gas Cell | Connected by optical fiber, easy to replace and low maintenance cost | Complex to replace and maintenance |
| Maintenance | ||
| Reliability | No moving parts | Moving parts existed |
>>>Technical Specifications
| SO2, NOx Analyzer | |
| Technical Principle | UV-DOAS |
| Installation type | Hot-wet Extractive |
| Measurement Range | 0~200ppm, 0~1000ppm, 0~3000ppm |
| Zero Drift | ≤ ±2%F.S. |
| Span Drift | ≤ ±2%F.S. |
| Accuracy | ≤ ±1% |
| Response Time(T90) | ≤ 60s |
| Linearity | ≤ ±1%F.S. |
| O2 Analyzer | |
| Technical Principle | Zirconia/Electrochemical |
| Measurement Range | 0~25% |
| Response Time(T90) | ≤ 60s |
| Linearity | ≤ ±2%F.S. |
| CO, CO2 Analyzer | |
| Technical Principle | NDIR |
| Installation type | Extractive |
| CO Measurement Range | 0~1000 ppm |
| CO2 Measurement Range | 0~20% |
| Zero Drift | ≤ ±2%F.S. |
| Span Drift | ≤ ±2%F.S. |
| Accuracy | ≤ ±1% |
| Response Time(T90) | ≤ 60s |
| Linearity | ≤ ±2%F.S. |
Technical Data for UV gas analyzer
| Project | Indicators |
| SO2 Detection range | Min:0-50ppm,Max:0-100%, |
| NO Detection range | Min:0-50ppm,Max:0-100%, |
| O2 Detection range | 0-25%, Electrochemical or zirconia |
| Linearity error | ≤±1%F.S. |
| Repeatability | ≤1% |
| Zero drift | ≤±1%F.S./ week |
| Span drift | ≤±1%F.S./week |
| Ambient temperature | 5ºC~45ºC |
| Response time(T90) | <10s |
| Size | 19" *3U*320mm |
| Analog interface | 3-way 4-20mA output,2-way 4-20mA input |
| Data interface | 4-way switch input; 8-way relay output |
| Communication Interface | 1-way RS-232,1-way RS-485(Supports Mod-bus protocol) |
| Power | 220VAC/50Hz 100W |
| Protection grade | IP42 |
| Sample gas input and output interface | Ø6 Tube Fittings |
>>> FAQ
1.How about the Delivery time?
Samples will be prepared within 15 Days after 100%
T/T in advance payment. QTY order will be delivered in 30 days.
2.What kind of payments does KELISAIKE support?
T/T, L/C, Western Union, Cash all are accepted.
3.What's the MOQ?
Generally speaking, the MOQ is 5PCS, but we can also provide
you samples for quality inspection.
4.Do you charge for the samples?
According to our company policy,we just charge the samples based on
EXW price.
5.Can you produce according to customers' design?
Sure.We are professional maunfacturer and OEM is welcome
Q1: Are you a trading company or manufacturer ? |
A1: We aremanufacturer. |
|
Q2: What about the payment method? |
A2: T/T, Paypal, Western Union, L/C is available |
|
Q3: Does your company accept customization? |
A3: We do customizing service for customers. |
|
Q4: What about the Shipment? |
A4: We’ll choose proper transportation mode based on the weight of goods, usually arrange shipment by air express such as DHL,FEDEX,TNT or UPS. |
|
Q5: What about after-sale service? |
A5:12 months warranty for all kinds of products. |
Add: No.9 Gaohu Road, Nanjing, 211100, China
Tel: +86 15050595939
Fax: +86 025 86644689
Skype: Saran Tong
Website: www.njklsk.com
|
K800 Series Fixed Gas Detector With 4-20mA/RS485 Output Atex/CE Certified For O2 / Lel / Co / H2s Detection |
|
K800 Series Fixed Gas Detector 21 Years Experience CE/UL Certified Customized For Various Gases |
|
K800-DA Fixed Gas Detector With UK/US Sensors CITY / Honeywell ±5%FS Accuracy 2-5 Years Lifetime |
|
K800-D Fixed Gas Detector With Relay Output Wireless Option Bluetooth/4G For Industrial Gas Leak Monitoring |
|
ATEX/UL/SIL3 Certified K800 Fixed Gas Transmitter 4-20mA Modbus Explosion Proof Exd II CT6 IP Protection |
|
Wireless Transmission Solar Charging Wall Mount Fixed Combustible Gas Detector |