JLSF-30HP Air Cooling Water Chiller For Chemical Fiber Paper Industry

Brand Name JIALIS
Model Number JLSF-30HP
Certification CE/ISO9001
Place of Origin Dongguan China
Minimum Order Quantity 1 set
Price Discuss
Payment Terms T/T
Supply Ability 300 units per month
Delivery Time 7 days
Packaging Details Plywood wooden box
Product Name Air Cooled Water Chiller
control system PLC/Microcomputer
outlet water temperature 5-50℃
Compressor Type Scroll/Semi-Hermetic/Hermetic
Evaporator Water Tank Coil/Shell and Tube/Plate Heat Exchanger
condenser Finned Tube
Condenser Fans Axial/Centrifugal
noise level ≤75dB(A)
Voltage 220V/380V/415V/440V/480V
Frequency 50HZ/60HZ
Refrigerant R22/R407C/R134A/R410A/R404A
protection system High/Low Pressure, Water Flow, Overload, etc.
Pump Centrifugal/vertical
Warranty 12 months
Detailed Product Description

JLSF-30HP Air Cooled Water Chiller Textile, Leather, Chemical Fiber, Paper Industry


Product Description:


Air-cooled chiller is a kind of chiller equipment, also known as chiller. It discharges heat by using an air condenser, so it is called "air-cooled", which is different from the way water-cooled chillers work, which uses a water condenser to discharge heat.

Compared with the traditional water-cooled chiller, the difference between the air-cooled chiller and the traditional water-cooled chiller is that it uses an air cooler as a condenser, and the fan blows the air required for heat dissipation from one side of the machine and exhausts it from the other side. Achieve cooling. Therefore, the air-cooled chiller does not need an external cooling water source, is independent, and is very convenient to install and move.




 

Product Features:


Air-cooled chiller is a common refrigeration equipment, its main features are as follows:

 

1.Independence: The air-cooled chiller does not need to be connected to an external cooling water source through pipes or water pumps. It is independent and easy to install and move.

 

2.High efficiency and energy saving: The air-cooled chiller adopts high-efficiency compressors and heat exchangers, which can reach the set temperature requirements in a short period of time, and can also reduce energy consumption and have better energy-saving effects.

 

3.Easy maintenance: The air-cooled chiller is simple in structure, easy to maintain, easy to clean and repair.

 

4.Low noise: The air-cooled chiller has low operating noise and will not interfere with the surrounding environment and personnel. It is suitable for places that require a quiet environment.

 

5.Automatic control: The air-cooled chiller adopts an advanced control system, which can automatically adjust the temperature and humidity to ensure stable and reliable cooling effect.

 

6.Flexibility: The air-cooled chiller can be used alone or in conjunction with other equipment to meet different needs.

 

In general, the air-cooled chiller has the characteristics of independence, high efficiency and energy saving, easy maintenance, low noise, automatic control and flexibility, and is an ideal equipment widely used in various refrigeration needs.

 

 

Working Principle:


The main components of an air-cooled chiller include a compressor, an air condenser, an expansion valve, and an evaporator. Here is a basic overview of its workflow:

1.The compressor takes in low-pressure, low-temperature refrigerant gas and compresses it into high-pressure, high-temperature gas.
 

2.This high-temperature, high-pressure refrigerant gas enters the air condenser, exchanges heat with the ambient air, and discharges heat to the environment, while the refrigerant condenses from a gaseous state to a liquid state.
 

3.The high-pressure refrigerant liquid passes through the expansion valve, the pressure suddenly drops, and it turns into a low-pressure and low-temperature refrigerant liquid.
 

4.The low-temperature and low-pressure refrigerant liquid enters the evaporator, absorbs indoor heat, evaporates into a gaseous state by itself, and the indoor temperature drops to achieve the purpose of refrigeration.
 

5.The refrigerant gas is sucked into the compressor again to complete a cycle.
 

The advantages of air-cooled chillers include simple installation, no need for cooling towers and cooling water pumps, and low maintenance costs. However, its efficiency is lower than that of water-cooled chillers, especially at high ambient temperatures, and its efficiency will be further reduced

① Compressor⑤ Evaporator⑨ Temperature sensor⑬ Bypass valve
② Condenser⑥ Ball valve⑩ Water tank⑭ Low voltage controller
③ Filter drier⑦ Antifreeze switch⑪ Water pump pressure gauge⑮ High voltage controller
④ Expansion valve⑧ Float switch⑫ Water pump

⑯ Pressure relief valve

 

 

 

Techinical Parameters:

 

ModelJLSF-1HPJLSF-2HPJLSF-3HPJLSF-4HPJLSF-5HPJLSF-6HPJLSF-8HPJLSF-10HP
Cooling capacityKW/h3.16.29.312.415.518.624.831
Kcal/h2,7005,4008,10010,80013,50016,20021,60027,000
Temperature range5℃-35℃(Below 0℃ can be customized)
Power supply1PH-220V 50HZ/60HZ     3PH-380V/415V 50HZ/60HZ
Total powerKW1.212.032.843.74.55.77.338.83
CompressorType Hermetic scroll type or piston
PowerKW0.751.502.253.003.754.506.007.50
Circulating pumpPowerKW0.3750.3750.3750.3750.750.750.751.5
Headm2222222223232321.5
RefrigerantType R22/R407c/R134a/R410a
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volumeKg0.501.001.502.002.503.004.005.00
EvaporatorFlowm³/h0.820.981.451.882.422.923.754.85
water capacity0.0280.040.050.050.0650.0650.130.18
Diameterinch1/2"3/4"1"1-1/2"1-1/2"
CondensatorTypeEfficient brass sets corrugated aluminum fin
FanTypeAxial flow
air volumem³/h100020003000400050006000800010000
Protective deviceHigh and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine sizeLmm680800104011401140120014001400
Wmm420480555620620650725725
Hmm720850106012001200116014501450
Unit weightKg6090130140170210270350

 

 

ModelJLSF-12HPJLSF-15HPJLSF-20HPJLSF-25HPJLSF-30HPJLSF-40HPJLSF-50HPJLSF-60HP
Cooling capacityKW/h37.246.56577.593124155186
Kcal/h29,05937,96550,80561,68374,99297,675116,521156,249
Temperature range5℃-35℃(Below 0℃ can be customized)
Power supply1N-220V 50HZ/60HZ      3N-380V/415V 50HZ/60HZ
Total powerKW11.413.6219.822.7528.339.246.7556.1
CompressorType Hermetic scroll type or piston
PowerKW911.251518.7522.53037.545
Circulating pumpPowerKW1.51.52.22.24445.5
Headm21.521.5222225252526
RefrigerantType R22/R407c/R134a/R410a
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volumeKg7.29.112.215.318.624.530.636.8
EvaporatorFlowm³/h5.817.610.1612.3415.219.5323.330.52
water capacitym³/h0.180.210.280.320.320.610.660.72
Diameterinch1.5"2"2.5"3"
CondensatorType Efficient brass sets corrugated aluminum fin
FanType Axial flow
air volumem³/h1200015000200002500030000400005000060000
Protective deviceHigh and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine sizeLmm14001750200020002200200020002400
Wmm725750900900900180018001800
Hmm14501500177017701770220023002300
Unit weightKg370480590590880100012801420

 


Application Industry:


The application of chillers in the chemical and fiber industry mainly includes the following aspects:

 

1.Cooling plastics: Chillers are commonly used in the chemical fiber industry to provide cooling for plastic processing to prevent thermoplastics from deforming during processing.

 

2.Cooling reactors: Reactors in the chemical industry need to be cooled to control the temperature of the reaction to ensure the reaction effect, and the chiller can provide a stable cooling effect.

 

3.Cooling textiles: Textile processing in the chemical fiber industry requires temperature control, and chillers can provide cooling for textiles to ensure product quality.

 

4.Cooling dyes: Dye manufacturing needs to control the temperature, and the chiller can provide refrigeration for the dyes to ensure the quality of the dyes.

 

In general, chillers in the chemical and chemical fiber industry have a wide range of applications, which can provide stable cooling effects for all links and ensure product quality and production efficiency.

 


  Automotive Manufacturing          Chemical Engineering              Electronics Industry                 Electroplating Industry
 

  Injection Molding Industry          Pharmaceutical Industry         Plastic Packaging Industry            Printing Industry

 

 

Upport and Services:


Air Cooled Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

 

 

Packing and Shipping:


Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

 

 

Product Maintenance:


The air-cooled chiller is an important refrigeration equipment, and its normal operation requires regular maintenance. The following are the issues that need attention in the maintenance of air-cooled chillers:

 

1.Regular cleaning: The radiator and fan of the air-cooled chiller need to be cleaned regularly to ensure its heat dissipation and ventilation effects, and to prevent dust and debris from affecting the cooling effect.

 

2.Replace the filter: The air filter of the air-cooled chiller needs to be replaced regularly to prevent dust and impurities from entering the machine, affecting the cooling effect and machine life.

 

3.Check the refrigerant: The refrigerant of the air-cooled chiller needs to be checked regularly to ensure that the amount of refrigerant is within the normal range, and to add or replace the refrigerant in time.

 

4.Check the electrical system: The electrical system of the air-cooled chiller needs to be checked regularly, including cables, wiring, insurance, etc., to ensure its safety and reliability.

 

5.Check the mechanical system: The mechanical system of the air-cooled chiller needs to be checked regularly, including the compressor, expansion valve, motor, etc., to ensure its normal operation and life.

 

6.Regular maintenance: Air-cooled chillers need regular maintenance, including lubrication, tightening screws, adjustments, etc., to ensure their normal operation and life.

 

7.Pay attention to safety: When maintaining the air-cooled chiller, you need to pay attention to safety to avoid accidents such as electric shock, cutting, and scalding.

 

To sum up, the maintenance of air-cooled chillers needs to pay attention to many aspects. Regular maintenance can ensure its normal operation and life, reduce the failure rate, and improve work efficiency.

 

 