| X-ray Source |
|---|
| Type | Closed, microfocus |
| Max Tube Voltage | 90kV |
| Max Tube Current | 200μA |
| Focal Spot Size | 5μm |
| Function | Auto preheat |
| Flat Panel Detector |
|---|
| Effective Area | 130mm×130mm |
| Pixel Size | 85μm |
| Resolution | 1536×1536 |
| Frame Rate | 20fps |
| Tiltable Angle | 60° |
| Table |
|---|
| Size | 530mm×530mm |
| Detectable Area | 500mm×500mm |
| Max Load | 10kg |
| Equipment |
|---|
| Magnification | Geometry 200X | System 1500X |
| Inspection Speed | Max 3.0s/point |
| Dimensions | 1360mm (L) × 1365mm (W) × 1730mm (H) |
| Weight | 1200kg |
| Power Supply | AC110-220V 50/60HZ |
| Max Power | 1500W |
| Industrial PC | I5 CPU, 8G RAM, 500GB SSD |
| Displayer | 24" HDMI LCD |
| Safety Features |
|---|
| Radiation Leakage | No leakage, international standard: ≤1μSv/h |
| Lead Glass Observation Window | Transparent lead glass window shields radiation to observe inner
status |
| Window and Back Door Safety Interlock | X-ray tube powers off immediately when window or back door opens |
| Electromagnetic Safety Switch | Locks when X-ray is on, preventing observation window opening |
| Emergency Stop | Located next to operation position, press to power off |
| Tube Protection | Software prevents leaving without closing X-ray tube |
| Function Module | Operation |
|---|
| Operation Control | Keyboard and mouse can finish all operations |
| X-ray Tube Control | Mouse click to turn on/off X-ray; real-time display of tube voltage
and current with adjustable settings |
| Status Bar | Indicates interlock status, pre-heat status, and X-ray status by
flashing red and green |
| Image Effect Adjustment | Adjustable brightness, contrast and gain for optimal image quality |
| Product List | Save inspection parameters for efficient recall when inspecting
same products |
| Navigation Window | Click anywhere in table photo to automatically move table to
selected position |
| Motion Axis Status | Display real-time coordinates |
| Inspection Result | Display measurement results (voids rate, distance, area, etc.) in
order |
| Speed Control | Adjustable movement speed for each axis (slow, normal, fast) |
| Voids Rate Measurement |
|---|
| Automatic Calculation | Click two points to define rectangle; software automatically
measures solder ball edges, pads, and internal voids |
| Parameters Adjustment | Adjust grayscale threshold, pixel, contrast, size filtering for
accurate results |
| Manual Void Addition | Draw polygons or free figures to calculate as voids in void rate |
| Parameter Saving | Save measurement parameters for efficient recall with same products |
| Other Measurement Functions |
|---|
| Distance | Measure vertical distance from point to baseline |
| Distance Rate | Measure soldering rate of through-hole components |
| Angle | Measure angle between defined rays |
| Radius | Measure round components like solder balls |
| Perimeter | Measure square components including length, width and area |
| Automatic Inspection |
|---|
| Manual Setting | Set any table positions as inspection points for automatic
inspection |
| Array | Automatically inspect regular patterns using row and column
settings |
| Automatic Identification | Software automatically identifies positions with obvious features |