DP-RC-8STA Tablet Drug Dissolution Tester Dual Function
|
>DP-RC-8STA Drug tablet dissolution testerInstrument structure and features: >Ø DP-RC-8STA is a dual-function model for electric lift head and head reversal. The operation space is large, which is convenient for medicine, cup change and rehydration operation. >Ø The water tank is arranged in a single row. It can be installed with 6 baskets or pulp poles and can be installed with 8 vessels. >Ø Dissolution cup and water tank have no gap design to ensure automatic center positioning. Eliminate system errors. >Ø Removable electronic temperature sensor can display and monitor the temperature of each point water bath. >Ø friendly man-machine interface, the instrument uses color large-screen liquid crystal display, intelligent menu operation. >Ø The time system consisting of a new architecture ensures smooth and accurate timing of the instrument. >Ø With self-test function and automatic protection function, it can give a variety of fault alarm signals. >Ø The installation position of the water bath can be adjusted and locked, and the vertical axis of the pulp bar, the rotating basket and the dissolution cup is automatically centered. >Ø The pulp rod, basket and basket made of high quality imported 316L stainless steel material meet the requirements of Chinese Pharmacopoeia. >Ø The instrument provides “program control test” function to execute 12 sets of preset sampling program combinations, suitable for routine repeatability test. >Ø The instrument provides “basic test” function to change the test parameters at any time during the test, which is convenient for research tests. >Ø The instrument provides “automatic warm-up” function to start preheating bath at unattended time, saving manpower and time. >Ø Optional standard cup method accessories
Applicable standards: ★ "Pharmacopoeia of the People's Republic of China" 2015 edition. ★ Food and Drug Administration, “Guidelines for Mechanical Verification of Dissolution Apparatus” ★ Industry standard "Drug dissolution tester" JB/T20076-2005
Main Specifications: >1. >Level: inclination ≤0.5° (measured in two vertical directions after installation) >2. >Basket paddle (axis) verticality: ≤0.5° off vertical >3. >Dissolution cup verticality: ≤1° deviation from the vertical direction >4. >Coaxiality between the vessel and the basket (paddle) axis: Offset axis ≤1.0mm >5. >Basket (paddle) shaft swing: swing ≤ 0.3mm >6. >Basket swing: swing ≤0.5mm >7. >Depth of basket (paddle): 25±2mm >8. >Basket (paddle) shaft speed: ±4%mm >9. >Medium temperature in each vessel: 37°C ± 0.3°C >10. >Vibration: ≤0.1mi1 >11. >Speed range: 25-250 rpm >12. >Speed resolution: 1 rev / min >13. >Water bath temperature range: room temperature -45°C >14. >Temperature resolution: 0.1°C >15. >Temperature control accuracy: ≤ ± 0.3°C >16. >Cumulative time: 99 hours, 59 minutes and 59 seconds. (Basic experiment timing) >17. >Number of sampling cycles: 1-12 different sampling periods can be preset. >18. >Sampling cycle time: 99 hours and 59 minutes per cycle can be set arbitrarily, 12 sampling cycles can be counted down in stages, or continuous countdown. >19. >Timed on/off time: up to 99 hours and 59 minutes >20. >Standard: 6 pulp 8 cups >21. >Working noise: <60dB >22. >Power maximum power: 1350W >23. >Dimensions: length * width * height 910mm * 440mm * 510mm
The following is a brief introduction to a set of control interfaces: Products Gallery >> >> >> |
| Product Tags: Drug Dissolution Tester Dual Function Tablet Drug Dissolution Tester |
|
DPS-8AT Automatic Sampling Dissolution Tester |
|
DP-RC-1 Capsule Tablet Drug Dissolution Tester Automation 110V / 220V 50Hz |
|
DP-RC-8D 8 Cups Drug Tablet Dissolution Tester Intelligent High Head Structure Design |
|
DP-RC-8DA Intelligent Drug Tablet Dissolution Tester 25-250 Rpm Speed range |
|
Self Test Automatic Tablet Drug Dissolution Tester 14 Cups DP-RC-12DF |
|
DP-RC-6ST 1100W Drug Dissolution Tester 6 Cups |