China Aluminum Power Cable manufacturer
Zhenglan Cable Technology Co., Ltd
Zhenglan Cable Technology Co., Ltd Make Cable with Heart!
1
Home > Products > Bare Aluminum Conductor >

ACSR AAC AAAC Aluminium Bare Conductor Cable Overhead Transmission Line

ACSR AAC AAAC Aluminium Bare Conductor Cable Overhead Transmission Line

Brand Name Zhenglan Cable
Model Number All Aluminum Bare Condutor
Certification 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007
Place of Origin Henan, China
Minimum Order Quantity Negotiable
Price Negotiable
Payment Terms T/T, L/C, Western Union
Supply Ability 150 Kilometer/Kilometers per Month
Delivery Time 10-15 days
Packaging Details Wooden drum, wood and steel drum,as customer's request
Material aluminum
Insulation Material None
Core Customized
Cable Drum Length Customized
characted Bare Conductor
Total Area 18.7~1211
Structure Stranded
Certificate ISO900-2008, ISO14001-2004 CCC
Detailed Product Description

Chinese Manufacture Various Standards and Specifications Overhead Transmission Line ACSR/AAC/AAAC/Aluminium Bare Conductor cable

 

 

APPLICATION

AAC, AAAC conductor widely used in power transmission lines with various voltage levels.Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.

 

STANDARD

Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110 standards.

 

AAC/AAAC/ACSR/ACAR Conductor Specification:


(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)

(3) aluminum conductor steel reinforced (ACSR)

(4) anti-corrosion type ACSR

(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR

 

TECHNICAL DATA

Numbers of WiresModules of ElasticityCoeficient of linear Expansion
ALSTEELKg/mm2Lb/in21/Cº1/Fº
618111.5 x10619.1 x10-610.6 x10-6
677711.0 x10619.8 x10-611.0 x10-6
12710715.2 x10615.3 x10-68.5 x10-6
181679.5 x10621.2 x10-611.8 x10-6
2477410.5 x10619.6 x10-610.9 x10-6
2677710.9 x10618.9 x10-610.5 x10-6
2877911.2 x10618.4 x10-610.2 x10-6
3078211.6 x10617.8 x10-69.9 x10-6
30198011.4 x10618.0 x10-610.0 x10-6
32198211.7 x10617.5 x10-69.7 x10-6
547709.9 x10619.3 x10-610.7 x10-6
5419689.7 x10619.4 x10-610.8 x10-6

 

CONSTRUCTION PARAMETERS

• IEC 60189

CodeNominal AreaStrandingOverall DiameterWeightBreaking LoadElectrical Resistance @20°Current Rating*
 ALSTEELTOTALALSTEEL     
 mm2mm2mm2No.xmmNo.xmmmmKg/KmKNΩ/KmA
16162.6718.76/1.841/1.845.5264.66.081.793485
25254.1729.26/2.301/2.306.9100.99.131.1478112
40406.6746.76/2.911/2.918.73161.514.40.7174150
636310.573.56/3.661/3.6610.98254.421.630.4555198
10010016.71176/4.611/4.6113.83403.834.330.2869263
1251256.9413218/2.971/2.9714.85397.929.170.2304299
12512520.414526/2.477/1.9215.64503.945.690.231302
1601608.8916918/3.361/3.3616.8509.336.180.18347
16016026.118626/2.807/2.1817.74644.957.690.1805351
20020011.121118/3.761/3.7618.8636.744.220.144398
20020032.623326/3.137/2.4319.81806.270.130.1444402
25025024.627522/3.807/2.1121.53880.668.720.1154458
25025040.729126/3.507/2.7222.161007.787.670.1155461
31531521.833745/2.997/1.9923.911039.679.030.0917526
31531551.336626/3.937/3.0524.871269.7106.830.0917530
40040027.742845/3.367/2.2426.881320.198.360.0722607
40040051.945254/3.077/3.0727.631510.3123.040.0723610
45045031.148145/3.577/2.3828.561485.2107.470.0642651
45045058.350854/3.267/3.2629.341699.1138.420.0643655
50050034.653545/3.767/2.5130.091650.2119.410.0578693
50050064.856554/3.437/3.4330.871887.9153.80.0578697
56056038.759945/3.987/2.6531.831848.2133.740.0516741
560*56070.963154/3.6319/2.1832.682103.4172.590.0516745
63063043.667445/4.227/2.8133.752079.2150.450.0459794
630*63079.871054/3.8519/2.3134.652366.3191.770.0459798
71071049.175945/4.487/2.9935.852343.2169.560.0407851
710*71089.980054/4.0919/2.4536.792666.8216.120.0407856
800*80034.683572/3.767/2.5137.612480.2167.410.0361910
800*80066.786784/3.487/3.4838.282732.7205.330.0362912
800*80010190154/4.3419/2.6139.093004.9243.520.0362916
900*90038.993972/3.997/2.6639.92790.2188.330.0321972
900*9007597584/3.697/3.6940.593074.2226.50.0322974
1000*100043.2104372/4.217/2.8042.083100.3209.260.02891031
1120*112047.3116772/4.4519/1.7844.53464.9234.530.02581096
1120*112091.2121184/4.1219/2.4745.313811.5283.170.02581100
1250*1250102135284/4.3519/2.6147.854253.9316.040.02321165
1250*125052.8130372/4.7019/1.88473867.1261.750.02311163
1120*112091.2121184/4.1219/2.4745.313811.5283.170.02581100

     

   

 

 

 Why you choose us?

  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;

 

Product Tags: AAAC Aluminium Bare Conductor Cable   ACSR Aluminium Bare Conductor Cable   ACSR AAC Overhead Transmission Line  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Zhenglan Cable Technology Co., Ltd
Subject:
Message:
Characters Remaining: (80/3000)