Whole House Lightning Protection T1 T2 SPD Three Phase 280V 12.5kA 30kA 50kA DIN Rail Mount
|
|
LPM H12.5M-280/3+NPE is a T1+T2 level power surge protector designed for three-phase power supply systems. It adopts a mixed-technology design (MOV for L-N, GDT for N-E) to provide comprehensive
protection against direct and indirect lightning strikes.
Application scenarios Suitable for installation in LPZ 0A-B and subsequent lightning protection zones to ensure effective T1+T2 protection.
Specifications & Parameters
Mechanical Parameters
Installation Tips 1.Install the SPD in LPZ 0A-B or subsequent lightning protection zones to ensure effective T1+T2 protection. 2.Use wiring with cross-sectional area 2.5mm²-32mm² and tighten screws to 5N·m torque. 3.The pluggable module design allows for hot-swapping, reducing downtime during maintenance. 4.Regularly check the status window; replace the module immediately if it turns red (failure status). 5.Ensure the grounding system meets requirements (ground resistance ≤4Ω) for optimal surge diversion. 6.Avoid using the product in environments with strong vibration beyond its anti-vibration capacity.
FAQ Q1: What is the mixed-technology design of the product? A1: It uses MOV (Metal Oxide Varistor) for L-N protection and GDT (Gas Discharge Tube) for N-E protection, combining the advantages of both technologies for optimal
performance. Q2: What is the function of the pluggable module design? A2: Yes, the pluggable module design allows for hot-swapping, enabling module replacement without disconnecting the power supply. Q3: What is the anti-vibration design used for? A3: It ensures the product operates stably in industrial environments with vibration, such as manufacturing plants and power plants. Q4: What is the difference between L-N and N-E response times? A4: The L-N response time is ≤25ns (faster for line-neutral surges), while the N-E response time is ≤100ns, matching the characteristics
of different surge paths. Q5: Can it be used in solar power systems? A5: Yes. It is suitable for three-phase power systems in solar parks, providing comprehensive lightning protection for inverters and distribution systems. |
||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: Three Phase T1 T2 SPD Whole House Lightning Protection SPD Whole House Lightning Protector 50kA | ||||||||||||||||||||||||||||||||||||||||||||||
|
Home Office T1 T2 SPD Single Phase Surge Protector 220V 15kA 30kA |
|
Whole House Lightning Protection T1 T2 SPD Three Phase 280V 12.5kA 30kA 50kA DIN Rail Mount |
|
T1 T2 Whole Home Surge Protector SPD 3 Phase 220V 25kA Extreme Environment Protection |
|
Lightning Protection T1 T2 SPD 3 Phase Home Surge Protector 220V 25kA 40kA 80kA |
|
Surge Protection Home T1 T2 Type Three Phase Surge Protector AC 380V SPD |