Lightning Protection T1 T2 SPD 3 Phase Home Surge Protector 220V 25kA 40kA 80kA
|
|
LPM 25B-385/4/LPM 50B-385/4 is a T1+T2 level power surge
protector. It integrates primary (T1) and secondary (T2) protection, providing
comprehensive shielding against direct and indirect lightning
strikes.
Applications Suitable for installation in LPZ 0A-B and subsequent lightning
protection zones, used as a lightning arrester for
three- phase power supply systems.
Product Specification
mechanical parameters
Installation Tips 1.Install the lightning protection box in a dry, well-ventilated indoor environment, away from flammable materials. 2.Use wires with cross-sectional area 2.5mm²~10mm², and tighten the screws to 5N·m torque. 3.Ensure reliable grounding with ground resistance ≤4Ω to ensure optimal surge diversion effect. 4.Regularly check the lightning strike counter and LED status indicator; replace the product immediately if it fails. 5.Do not disassemble the product without authorization to avoid damage to internal components.
FAQ
Q1: What is Kevin Connection and when should it be used? A1: Kevin Connection is a wiring method that minimizes current measurement errors. It is recommended for large current applications (≥25kA) to ensure accurate protection triggering.
Q2: Can it be used in 400V three-phase systems? A2: Yes, with maximum continuous operating voltage 385Vac, it is compatible with 400V three-phase systems (230V phase-neutral).
Q3: What is the difference between T1 and T2 level protection? A3: T1 level handles direct lightning strikes (10/350μs waveform), while T2 level protects against indirect surges (8/20μs waveform). This product integrates both for comprehensive protection.
Q4: What is the flame-retardant grade of the housing? A4: The housing is made of mineral nylon PA6 with V0 flame-retardant grade, which self-extinguishes within 10 seconds after ignition.
Q5: What is the response time of the product? A5: The response time is ≤100ns, ensuring rapid diversion of surge current to protect sensitive equipment.
|
||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: Lightning Protection T1 T2 SPD 3 Phase Home Surge Protector Home Surge Protector 220V |
|
Home Office T1 T2 SPD Single Phase Surge Protector 220V 15kA 30kA |
|
Whole House Lightning Protection T1 T2 SPD Three Phase 280V 12.5kA 30kA 50kA DIN Rail Mount |
|
T1 T2 Whole Home Surge Protector SPD 3 Phase 220V 25kA Extreme Environment Protection |
|
Lightning Protection T1 T2 SPD 3 Phase Home Surge Protector 220V 25kA 40kA 80kA |
|
Surge Protection Home T1 T2 Type Three Phase Surge Protector AC 380V SPD |