T2 T3 Lightning Surge Protection Device 3 Phase AC SPD 220V 20kA 40kA

Brand Name LLH
Model Number SLV-40T
Place of Origin Guangdong Province, China
Minimum Order Quantity 1 piece
Payment Terms L/C,D/A,D/P,T/T,Western Union
Supply Ability 5000-10000 pieces/month
Delivery Time 7-15 days
Packaging Details Box
Price USD$120-USD$190
Nominal Operating Voltage (Un) 220Vac(50Hz)
Maximum Continuous Operating Voltage (Uc) 320Vac(50Hz)
Nominal Discharge Current (In) 20kA/ 40kA
Maximum Discharge Current (Imax) 40kA/ 80kA
Voltage Protection Level (Up) ≤1.25kV (L123-N)、≤1.8kV (L123-E)、≤650V (N-E)
Response Time ≤25ns
Detailed Product Description
Product features
● Full mode protection
● No leakage current, no afterflow
● Large flow capacity and super low residual pressure
● Suitable for installation in LPZ 1-2 and subsequent lightning protection zones, suitable for fine lightning protection devices in three-phase power supply systems.

 

Product Specification


StandardsIEC 61643.11
SPD typeT2,T3
Models

SLV-40T

SLV-80T

Nominal operating voltage Un220Vac(50Hz)
Maximum continuous operating voltage Uc320Vac(50Hz)
Nominal discharge current (8/20μs) In20kA/40kA
Maximum discharge current (8/20μs) Imax40kA/80kA
Voltage protection level In@Up≤1.25kV/≤1.8kV
L123-N,L123-E,N-E(3kA&6kV) Uoc≤650V
Response time tA≤25ns
Protection CircuitL1,L2,L3-N,L1,L2,L3-E,N-E
Counting current range0.5kA(8/20μs)-80kA(8/20μs)
Counting digit0-999

 

Mechanical parameters

 

Installation method4 fixed holes, DIN Rail 35mm
Screw torque5N*m
Strip length12mm
Wiring cross-sectional area2.5mm²-10mm²
Product size

SLV-40T:178mmx116mmx75mm

SLV-80T:197mmx139mmx90mm

Shell material and surface technologyCold rolled steel plate painted black
Deterioration indicationLED green: OK; Off: Fail
Remote signaling contact typeNormally closed and normally open switching contacts
Remote signaling contact switching ability125 Vac / 1 A, 125 Vdc A / 0.2
Maximum connection capacity of remote signaling2.5mm²
Installation positionIndoor
Degrees of protection provided by enclosureIP20
Temperature range-40℃…+80℃
Humidity rangeRelative humidity ≤ 95% (max 40 ℃)

 

Notices
1.Install the SPD in LPZ 1-2 or subsequent lightning protection zones, ensuring the distance to protected equipment does not exceed 10 meters.

2.Use wiring with cross-sectional area 2.5mm²-10mm² and tighten screws to 5N·m torque for secure connections.

3.Ensure reliable grounding with a ground resistance ≤4Ω to guarantee surge current diversion efficiency.

4.Replace the SPD immediately if the LED indicator turns off (failed status) or after experiencing a severe surge impact.

5.Do not disassemble the product by yourself; improper operation may damage internal components and cause safety risks.

6.Avoid using the product in environments beyond the specified temperature (-40℃~+80℃) and humidity range

 

FAQ
Q1: What is the difference between SLV-40T and SLV-80T?

A1: The core difference is nominal discharge current (In) and maximum discharge current (Imax): SLV-40T has In=20kA/Imax=40kA, while SLV-80T has In=40kA/Imax=80kA. Other performance parameters and structural design are consistent.

 

Q2: Can this SPD be used for single-phase power systems?

A2: No, SLV-40T/SLV-80T is specifically designed for three-phase systems. For single-phase applications, choose SLV-40S/SLV-80S series products.

 

Q3: What is the function of remote signaling contacts?

A3: The normally closed and normally open switching contacts allow connection to monitoring systems, enabling remote alerts when the SPD fails.

 

Q4: Does the product require regular maintenance?

A4: Regular visual inspection is recommended (quarterly): check LED status and wiring tightness. No additional maintenance is needed under normal operating conditions.

 

Q5: Is the SPD compatible with different grounding systems?

A5: Yes, it is compatible with TN, TT, and IT grounding systems, as long as the grounding resistance meets the requirement (≤4Ω).