Wotech 15Kw Customized Chinese Manufacture Water Source Heat Pump with DC Rotary Compressor | | | WW05VM | WW07VM | WW09VM | WW10VM | Heating1 A7 W35 | Output Capacity | kW | 1.89~4.80 | 2.84~7.20 | 3.62~9.20 | 4.58~10.11 | | Input Power | kW | 0.36~1.09 | 0.52~1.57 | 0.71~2.19 | 0.88~2.31 | | COP | - | 4.39~5.26 | 4.59~5.39 | 4.19~5.07 | 4.38~5.16 | | Input Current | A | 1.64~5.01 | 2.41~7.17 | 3.27~10.04 | 4.06~11.00 | Heating2 A7 W55 | Output Capacity | kW | 1.69~4.46 | 2.64~6.95 | 2.85~8.56 | 3.74~9.87 | | Input Power | kW | 0.52~1.65 | 0.77~2.40 | 0.85~3.01 | 1.10~3.40 | | COP | - | 2.70~3.25 | 2.89~3.41 | 2.84~3.32 | 2.90~3.39 | | Input Current | A | 2.39~9.43 | 3.54~10.98 | 3.93~13.78 | 5.03~15.55 | Heating2 A-10 W35 | Output Capacity | kW | 1.62~3.64 | 2.21~4.96 | 2.50~5.62 | 3.36~7.56 | | Input Power | kW | 0.46~1.46 | 0.60~1.84 | 0.70~2.14 | 0.94~2.85 | | COP | - | 2.50~3.45 | 2.70~3.65 | 2.63~3.56 | 2.65~3.60 | | Input Current | A | 2.14~6.36 | 2.77~7.95 | 3.21~9.24 | 4.30~13.33 | Heating3 A20 W55 | Output Capacity | kW | 2.30~5.76 | 3.51~8.78 | 4.49~11.22 | 4.98~12.16 | | Input Power | kW | 0.46~1.36 | 0.68~1.99 | 0.94~2.75 | 1.02~2.88 | | COP | - | 4.24~4.96 | 4.41~5.16 | 4.08~4.77 | 4.22~4.92 | | Input Current | A | 2.13~6.22 | 3.12~9.12 | 4.30~12.59 | 4.67~13.18 | Cooling4 A35 W18 | Output Capacity | kW | 3.06~6.89 | 3.40~7.71 | 4.37~9.85 | 4.53~10.20 | | Input Power | kW | 0.86~2.29 | 0.83~2.22 | 1.10~2.95 | 1.26~3.34 | | EER | - | 3.01~3.54 | 3.47~4.09 | 3.34~3.94 | 3.05~3.57 | | Input Current | A | 3.93~9.91 | 3.79~10.16 | 5.03~12.71 | 5.76~15.28 | Cooling5 A35 W7 | Output Capacity | kW | 1.48~4.91 | 2.30~6.63 | 2.95~7.03 | 4.14~9.32 | | Input Power | kW | 0.50~2.07 | 0.73~2.50 | 0.98~2.76 | 1.42~3.76 | | EER | - | 2.37~2.96 | 2.65~3.13 | 2.55~3.01 | 2.48~2.90 | | Input Current | A | 2.29~8.97 | 3.36~11.44 | 4.49~11.91 | 6.53~17.21 | Power Supply | | V/PH/HZ | 220-240V/1/50Hz | 220-240V/1/50Hz | 220-240V/1/50Hz | 220-240V/1/50Hz | ErP level(35℃) | | - | A+++ | A+++ | A+++ | A+++ | ErP level(55℃) | | - | A++ | A++ | A++ | A++ | SCOP(35℃) | | - | 4.85 | 5.07 | 5.07 | 5.26 | SCOP(55℃) | | - | 3.52 | 3.51 | 3.51 | 3.79 | Water SIWe Heat Exchanger | | - | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Display controller | | - | LCD touch screen | LCD touch screen | LCD touch screen | LCD touch screen | Backup heater (Optional) | | kW | 3kW | 3kW | 3kW | 3kW | Expansion vessel | | / | 3L | 3L | 3L | 3L | Refrigerant Type | | - | R290 | R290 | R290 | R290 | Max Oulet Water Temperature | | ℃ | 75 | 75 | 75 | 75 | Working Ambeint Temperature | | ℃ | -25~43 | -25~43 | -25~43 | -25~43 | Water connection | | inch | G1-1/4 | G1-1/4 | G1-1/4 | G1-1/4 | Sound pressure Level @1m | | dB(A) | 49 | 50 | 50 | 51 | Water Flow Rate | | m³/h | 0.45~1.10 | 0.60~1.50 | 0.80~1.95 | 0.85~2.15 | Net Dimension (L*W*H) | | mm | 1105*485*840 | 1105*485*840 | 1105*485*840 | 1105*485*840 | Note: 1.Outdoor air temperature 7℃ DB,6℃ WB;EWT 30℃,LWT 35℃. 2.Outdoor air temperature 7℃ DB,6℃ WB;EWT 47℃,LWT 55℃. 3.Outdoor air temperature 20℃ DB,15℃ WB;EWT 15℃,LWT 55℃. 4.Outdoor air temperature 35℃ DB,24℃ WB;EWT 12℃,LWT 7℃. 5.The Specifications are subject to changes without notice. 6.Relevant EU Standards and Legislation:EN14511,EN14825 | | | | | | | | | | WW12VM | WW15VM | WW12VT | WW15T | Heating1 A7 W35 | Output Capacity | kW | 4.65~11.80 | 5.89~14.96 | 4.65~11.80 | 5.89~14.96 | | Input Power | kW | 0.87~2.62 | 1.21~3.72 | 0.87~2.62 | 1.21~3.72 | | COP | - | 4.51~5.32 | 4.02~4.86 | 4.51~5.32 | 4.02~4.86 | | Input Current | A | 4.00~11.97 | 5.55~17.04 | 1.47~4.45 | 2.06~6.33 | Heating2 A7 W55 | Output Capacity | kW | 4.44~11.72 | 5.37~14.21 | 4.44~11.72 | 5.37~14.21 | | Input Power | kW | 1.38~4.26 | 1.71~5.32 | 1.38~4.26 | 1.71~5.32 | | COP | - | 2.75~3.22 | 2.67~3.12 | 2.75~3.22 | 2.67~3.12 | | Input Current | A | 6.31~19.48 | 7.86~25.99 | 2.34~7.23 | 2.90~9.03 | Heating2 A-10 W35 | Output Capacity | kW | 4.23~9.54 | 4.49~10.11 | 4.23~9.54 | 4.49~10.11 | | Input Power | kW | 1.18~3.57 | 1.27~3.87 | 1.18~3.57 | 1.27~3.87 | | COP | - | 2.67~3.58 | 2.61~3.52 | 2.67~3.58 | 2.61~3.52 | | Input Current | A | 5.40~15.54 | 5.83~16.83 | 1.66~6.07 | 2.13~6.58 | Heating3 A20 W55 | Output Capacity | kW | 5.71~14.28 | 7.24~18.10 | 5.71~14.28 | 7.24~18.10 | | Input Power | kW | 1.11~3.26 | 1.58~4.63 | 1.11~3.26 | 1.58~4.63 | | COP | - | 4.38~5.12 | 3.91~4.57 | 4.38~5.12 | 3.91~4.57 | | Input Current | A | 5.10~14.92 | 7.24~21.19 | 1.90~5.54 | 2.69~7.87 | Cooling4 A35 W18 | Output Capacity | kW | 5.53~12.03 | 7.01~15.26 | 5.53~12.03 | 7.01~15.26 | | Input Power | kW | 1.57~4.06 | 2.02~5.32 | 1.57~4.06 | 2.02~5.32 | | EER | - | 2.96~3.51 | 2.87~3.47 | 2.96~3.51 | 2.87~3.47 | | Input Current | A | 7.18~18.58 | 9.24~23.21 | 2.67~6.89 | 3.43~9.03 | Cooling5 A35 W7 | Output Capacity | kW | 4.08~10.99 | 5.17~11.64 | 4.08~10.99 | 5.17~11.64 | | Input Power | kW | 1.43~4.58 | 1.84~5.02 | 1.43~4.58 | 1.84~5.02 | | EER | - | 2.40~2.85 | 2.32~2.81 | 2.40~2.85 | 2.32~2.81 | | Input Current | A | 6.54~20.96 | 8.43~21.80 | 2.42~7.78 | 3.12~8.52 | Power Supply | | V/PH/HZ | 220-240V/1/50Hz | 220-240V/1/50Hz | 380-415V/3/50Hz | 380-415V/3/50Hz | ErP level(35℃) | | - | A+++ | A+++ | A+++ | A+++ | ErP level(55℃) | | - | A++ | A++ | A++ | A++ | SCOP(35℃) | | - | 5.05 | 5.05 | 5.05 | 5.05 | SCOP(55℃) | | - | 3.58 | 3.58 | 3.58 | 3.58 | Water SIWe Heat Exchanger | | - | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Display controller | | - | LCD touch screen | LCD touch screen | LCD touch screen | LCD touch screen | Backup heater (Optional) | | kW | 3kW | 3kW | 3kW | 3kW | Expansion vessel | | / | 5L | 5L | 5L | 5L | Refrigerant Type | | - | R290 | R290 | R290 | R290 | Max Oulet Water Temperature | | ℃ | 75 | 75 | 75 | 75 | Working Ambeint Temperature | | ℃ | -25~43 | -25~43 | -25~43 | -25~43 | Water connection | | inch | G1-1/4 | G1-1/4 | G1-1/4 | G1-1/4 | Sound pressure Level @1m | | dB(A) | 52 | 53 | 52 | 53 | Water Flow Rate | | m³/h | 1.05~2.60 | 1.30~3.20 | 1.05~2.60 | 1.30~3.20 | Net Dimension (L*W*H) | | mm | 1170*470*965 | 1170*470*965 | 1170*470*965 | 1170*470*965 | Note: 1.Outdoor air temperature 7℃ DB,6℃ WB;EWT 30℃,LWT 35℃. 2.Outdoor air temperature 7℃ DB,6℃ WB;EWT 47℃,LWT 55℃. 3.Outdoor air temperature 20℃ DB,15℃ WB;EWT 15℃,LWT 55℃. 4.Outdoor air temperature 35℃ DB,24℃ WB;EWT 12℃,LWT 7℃. 5.The Specifications are subject to changes without notice. 6.Relevant EU Standards and Legislation:EN14511,EN14825 | | | | | | | Model | | | WW20VT | WW22VT | Heating1 A7 W35 | Output Capacity | kW | 8.03~20.38 | 8.83~22.42 | | Input Power | kW | 1.53~4.70 | 1.75~5.39 | | COP | - | 4.34~5.25 | 4.16~5.04 | | Input Current | A | 2.60~7.99 | 3.14~9.64 | Heating2 A7 W55 | Output Capacity | kW | 7.18~19.02 | 8.24~21.82 | | Input Power | kW | 2.08~6.65 | 2.47~8.01 | | COP | - | 2.94~3.44 | 2.80~3.34 | | Input Current | A | 3.65~11.30 | 4.20~13.61 | Heating2 A-10 W35 | Output Capacity | kW | 6.28~14.15 | 6.65~14.97 | | Input Power | kW | 1.80~5.51 | 1.94~5.97 | | COP | - | 2.57~3.48 | 2.51~3.42 | | Input Current | A | 3.06~9.36 | 3.29~10.14 | Heating3 A20 W55 | Output Capacity | kW | 9.78~24.46 | 10.81~27.02 | | Input Power | kW | 1.98~5.80 | 2.30~6.72 | | COP | - | 4.22~4.94 | 4.02~4.70 | | Input Current | A | 3.37~9.86 | 4.11~12.02 | Cooling4 A35 W18 | Output Capacity | kW | 9.02~18.94 | 9.92~20.84 | | Input Power | kW | 2.44~6.03 | 2.75~6.79 | | EER | - | 3.14~3.69 | 3.06~3.60 | | Input Current | A | 4.14~10.24 | 4.67~11.53 | Cooling5 A35 W7 | Output Capacity | kW | 5.62~14.30 | 6.19~15.20 | | Input Power | kW | 1.89~5.67 | 2.14~6.38 | | EER | - | 2.52~2.97 | 2.38~2.89 | | Input Current | A | 3.21~9.63 | 3.63~10.84 | Power Supply | | V/PH/HZ | 380-415V/3/50Hz | 380-415V/3/50Hz | ErP level(35℃) | | - | A+++ | A+++ | ErP level(55℃) | | - | A++ | A++ | SCOP(35℃) | | - | 4.88 | 4.88 | SCOP(55℃) | | - | 3.48 | 3.48 | Water SIWe Heat Exchanger | | - | Plate heat exchanger | Plate heat exchanger | Display controller | | - | LCD touch screen | LCD touch screen | Backup heater (Optional) | | kW | 3kW | 3kW | Expansion vessel | | / | 5L | 5L | Refrigerant Type | | - | R290 | R290 | Max Oulet Water Temperature | | ℃ | 75 | 75 | Working Ambeint Temperature | | ℃ | -25~43 | -25~43 | Water connection | | inch | G1-1/4 | G1-1/4 | Sound pressure Level @1m | | dB(A) | 58 | 58 | Water Flow Rate | | m³/h | 1.70~4.30 | 1.90~4.75 | Net Dimension (L*W*H) | | mm | 1170*470*1395 | 1170*470*1395 | Note: 1.Outdoor air temperature 7℃ DB,6℃ WB;EWT 30℃,LWT 35℃. 2.Outdoor air temperature 7℃ DB,6℃ WB;EWT 47℃,LWT 55℃. 3.Outdoor air temperature 20℃ DB,15℃ WB;EWT 15℃,LWT 55℃. 4.Outdoor air temperature 35℃ DB,24℃ WB;EWT 12℃,LWT 7℃. 5.The Specifications are subject to changes without notice. 6.Relevant EU Standards and Legislation:EN14511,EN14825 | | | | | R290/R32 Monoblock Heat Pump For House Heating , Cooling And Domestic Hot Water Supply. Providing continuous spacing heating /cooling and hot water supply. The wotech R290 & R32 series multi-function heat pump has a range of benefits which sets it apart from the competition,including the unique designed fan housing. It significantly increased the airflow of the heat pump, making it more efficient, energy-saving, and environmentally friendly. High Efficiency Level A+++/A++ Wotech R290 & R32 monoblock heat pump has passed the Erp A+++/A++ energy class test of Intertek FAQ 1)Are you a manufacturer? Yes, we are a company and factory integrating R&D, production, and sales. At present, Wotech has three production bases in Shunde, Zhaoqing and Heyuan, Covering covering 100, 000 square meters. 2)Why should you select our heat pumps over those of other manufacturers? We have more than 19 years of experience in the heat pump field. Besides, we have a professional technical team, the industry's top heat pump laboratory, and automatic production lines. We can meet your diverse order requirements. 3)Do you offer OEM/ODM customised services? Yes. We are able to produce European-standard heat pumps under your brand according to your special needs. 4)Can you provide a sample service? Yes, we are able to provide sample services. 5)How can we guarantee product quality? With many years of heat pump export experience, we set up a top international quality control system to achieve the belief of making the best quality heat pumps for global user. |