XHHD530M
Description The hidden line buried line fault detector is a special instrument
for power, broadcasting, post and telecommunications departments,
as well as industrial and mining, rural areas to find underground
cables, including direct buried armored cable lines and buried line
faults. It can detect the direction of the buried line, the more
accurate underground position, the basic buried depth, and various
ground leakage faults, broken core faults, including lines under
paddy fields, cement roads, bricks and stones, asphalt roads, and
lines in the walls of buildings. Waterproof wires and cables used
on the ground can be detected by using this instrument through
appropriate methods.0 Transmitter
| The transmitter panel is equipped with "power switch", "power
indication"; "output selection", "high, medium, low"; "output
indication" and "K measurement" switching switches, and the
indicator light indicates the switching position; "output·KΩ
measurement" shares an output terminal, which is switched by the
"output·indication" and "KΩ measurement" switches; set "output 2"
output terminal; square meter head indicates output and KΩ
resistance. It can check the line on, off, mixed, and measure the
size of the ground leakage resistance. | | Output signal form | pulse period 1.34±0.15mS. Width 0.2 ±0.1mS intermittent period
1.8±1S. | | Output voltage | pulse period Upp high range greater than 1000V, medium range
greater than 60V, low range greater than 30V. | | KΩ measurement | It can check the side line on, off, mixed and leakage group size,
and determine the nature of the fault. | | The "output 2" output terminal | It can output peak pulse short-circuit current 1-5A. | | Output power | Pulse power greater than 2.5W (when high-end load resistance is
80KΩ). | | Power supply | 8.4V. |
ReceiverSet power switch, power indicator, "high gear", "low gear" switch; when there is a signal on the meter, it indicates the
positive direction or negative direction; there is an input
terminal on the upper side, which can be inserted into the probe or
plug-in plug respectively. | | Received signal form | pulse period 1.360.15mS | | width 0.20.1mS, intermittent period 1.81S. | | Power supply | 6V (4 No. 5 batteries) | | Detection fault range and detection accuracy | When the detection length is 3km, the burial depth is 2m short
circuit to the ground, and the leakage resistance of the leakage
fault is less than 500kΩ, the insertion measurement positioning
error is less than 0.2m. | | When detecting a broken core fault with a length of 1km and a
burial depth of 2m and good insulation to the ground, the
inspection positioning error is less than 0.4m. | | The actual detection length can exceed 1-5km and the burial depth
is 2-3m. | | Anti-interference performance | The received signal is clear and can detect underground wire faults
under 220 kV lines. | | Instrument working conditions | This instrument can work continuously in an environment with an
ambient temperature of -15 and an atmospheric pressure of
86-108Kpa. |
|