High-precision programmable AC power supplies save costs and
improve testing efficiency. They are energy-efficient with a quick
response. The TPA-100 series is a
high-quality, efficient, and highly programmable AC power supply
that utilizes PWM inverter technology. It facilitates the
simulation of various power supply conditions and distortions, as
well as the measurement and analysis of electrical characteristics.
It can conveniently simulate both normal and abnormal power
conditions and perform various analyses, making it suitable for use
in research and development, quality control, production, and more. Product Features: - Programmable output of sine waves, square waves, and clipped sine
waveforms;
- Programmable settings for voltage, frequency, phase, current
limiting, and distortion simulation functions;
- Capability to simulate utility waveform distortions;
- User-programmable automatic sequenced output of voltage waveforms;
- High precision measurement parameters such as voltage, current,
peak current, power, frequency, crest factor, power factor, inrush
current, apparent power (VA), etc.
- Power factor correction circuitry to improve the input power factor
to over 0.97, compliant with IEC standards;
- Utilization of Pulse Width Modulation (PWM) technology results in
compact and lightweight units.
- Generation of TTL signals upon output changes, facilitating the use
in automatic testing systems.
- Equipped with a GPIB interface.
(Basic) | TPA-110 | TPA-120 | (Rated Power) | 1KW @ 110V, 220V | 2KW @ 110V, 220V | (Phase) | 1Φ | 1Φ | (Efficiency ) | >80% (Typical) | >82% (Typical) | (Height) | 4u | 4u | (Crest Factor (Cf) ) | 3.5 | 3.5 | (Input) | (Voltage Range) | 180~254V | 190~254V | (Frequency Range) | 47~63Hz | 47~63Hz | (Current) | <10A | <15A | (Power Factor Full Load) | ≥0.965 | ≥0.985 | (Output) | (Voltage) | | | (Voltage Range) | 0<v≤300v< span=""> | 0<v≤300v< span=""> | (Phase) | 150V/300V/AUTO | 150V/300V/AUTO | (Accuracy) | 0.2% of F.S. | 0.2% of F.S. | (Resolution) | 0.1V | 0.1V | (Distortion) | <1% | <1% | (Line Regulation) | <0.1% | <0.1% | (Load Regulation) | <0.1% | <0.1% | (Temp. Coefficient) | <0.02%/°C | <0.02%/°C | (Current) | (Max RMS) | 10/5A | 20/10A | (Max Peak) | 35A/20A | 70A/35A | (Frequency) | (Range) | 45-500Hz | 45-500Hz | (Accuracy) | <0.1% | <0.1% | (Resolution) | 0.1Hz | 0.1Hz | (Measurement) | (Voltage) | (Range) | 0<v≤300v< span=""> | 0<v≤300v< span=""> | (Accuracy) | 0.2% +0.2% of F.S. | 0.2%+0.2% of F.S. | (Resolution) | 0.1V | 0.1V | (Current) | (Measure Range) | 0-140A | 0-140A | (Resolution) | 0.1A | 0.1A | (Accuracy) | 0.1% F.S. | 0.1% F.S. | (Frequency) | (Range) | 45-500Hz | 45-500Hz | (Measure Accuracy) | 0.02% | 0.02% | (Resolution) | 0.1Hz | 0.1Hz | (Power/Phase) | (Accuracy) | 1% F.S. | 1% F.S. | (Resolution) | 0.1W | 0.1W | (PC Interface) | IEEE-488 (GPIB) | (Operating) | 0~40°C | (Storage) | -40~+85°C | (Protection) | OPP, OLP, OTP, FAN Fail |
|