20mA MTL7796 MTL Intrinsically Safe Barriers , 2 Wire MTL Zener Barrier
|
MTL7796- MTL Instruments Intrinsically Safe Zener Barriers Product type : Zener Barriers Analogue inputs (high level) 2-wire transmitters, 4/20mA, conventional and smart The recommended barrier for use with 'conventional' and 'smart' 4/20mA transmitters (fed by a 26V regulated supply) is the MTL7787+. This provides up to 12.9V (14.6V for MTL7787P+) at Vwkg and 20mA for a transmitter and its lines as well as 5V for the typical 250O load. This application and this barrier is suitable for use with the optional power bus facility. The MTL7706+ is recommended for applications where an unregulated supply of up to 35V is used. It provides 16.0V for conventional and smart transmitters at 20mA, as well as 5V for a typical 250O load. With the MTL7706+ terminal 3 is negative with respect to earth, so the connections to terminals 3 and 4 should be reversed. Vibration probes The 3-wire transmitters used with vibration monitoring equipment are invariably supplied by a –24V dc power supply – hence the recommended barrier choice is the negatively-polarised MTL7796-.
Related Product Recommendation:
Our Advantage: Best possible prices and delivery time Long time experience in the field Well trained staff Own warehouse facilities Best relationships with branch office of manufacture Flexible and individual service for you Cheap and safe forwarder for shipments (air)
Frequently Asked Questions: Q: Does your goods are new and original? A: Yes, they are new and original.
Q: How long warranty? A: One-year warranty.
Q: Does any certificates can be provided? A: Yes, it depends on what product you request, please check details with our sales.
Q: Varied payment methods. A: We adopt T/T, alipay and paypal and Currency in EURO,USD,RMB
Q: SHIPPING: A: We can shipping all over the world.via DHL,UPS,Fedex,TNT and IPS,PDE,BRE,KARAPOST etc.
Our Product Range: Transmitter, Safety barries, Flow meters, Probe, Sensor, Transducer. Valves,Analysis meter, Positioner, Acuator, etc. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: MTL7796 MTL Intrinsically Safe Barriers 20mA MTL Intrinsically Safe Barriers 2 wire MTL Zener Barrier |
![]() |
0.11 Kg MTL and P F Safety Barrier for Manufacture within PLC SYSTEM Control System |
![]() |
MTL5549Y Isolating Driver Two Channel For 4 - 20mA HART Valve Positioner |
![]() |
MTL5546 MTL IS Isolator 5500 Series Isolating Driver |
![]() |
HART MTL5546 MTL Safety Barrier , 20mA Mtl Barriers 5500 Series |
![]() |
Pulse Isolator MTL5532 MTL Instrument From Switch Proximity Detector |
![]() |
9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface |