MTL7788 Intrinsically Safe Zener Safety Barrier Encoder DIN Rail Mounting
|
MTL7788+| Instruments | Proximity Detector Interface
MTL7788+ DIN rail mounting isolation barrier, MTL7700 series DIN
rail mounting safety barrier.
All MTL7700 series Zener barriers are designed according to the same design principles. Each channel consists of a secondary pulse detecting Zener or forward connecting diode and a “reliable” terminating resistor. In the event of an electrical fault in the safety zone, the diode limits the voltage that can reach the hazardous area, while the resistor has a current limiting effect. A fuse protects the diode, and a two-stage voltage limiting function ensures continuous protection in the event of a failure in either stage. No active output current limiting circuitry is used. All models are certified “ia” - for all zones and “IIC” - for all explosive atmospheres (except MTL7707P+ and MTL7729P+, “ia” “IIB”).
Commonly Used MTL7700 Summary Table Type Application Main safety barriers Analog input (low level) RTD temperature detector, thermocouple, AC
sensor MTL7756ac MTL7755ac MTL7760ac Analog input (high level) Transmitter, 2-wire, 4/20mA MTL7706+ MTL7787+ MTL7787P+ MTL7788+ Analog Output Controller output, single wire to ground Controller output, neither wire grounded MTL7728+ MTL7787+ MTL7787P+ Digital (switch) input Switch/proximity switch MTL7787+ MTL7787P+ MTL7789+ MTL7741 MTL7742 MTL7743 MTL7744 MTL7745 Digital (Switching) Outputs Solenoids, Alarms, Light Emitting Diodes MTL7728+ MTL7707+ MTL7728P+ MTL7729P+ MTL7787+ MTL7787P+ Positive DC Systems Low Voltage to 12V DC Systems 18V DC Systems MTL7764+ MTL7767+ MTL7722+ AC and DC Systems High Voltage AC and DC Systems MTL7765ac MTL7778ac Negative/Floating Power Supply Digital (Switching) Outputs MTL7728- Spare Cord and Shield - MTL7799 Bus Power Usage - MTL7799 MTL7706 MTL7707+ MTL7707P+ MTL7741 MTL7742 MTL7743 MTL7744 MTL7745 MTL7787+ MTL7787P+ MTL7788+ MTL7789+
|
||||||
Product Tags: MTL7788 Zener Safety Barrier Zener Safety Barrier Encoder MTL7788 mtl intrinsically safe barriers |
![]() |
MTL5549Y Isolating Driver Two Channel For 4 - 20mA HART Valve Positioner |
![]() |
MTL5546 MTL IS Isolator 5500 Series Isolating Driver |
![]() |
9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface |
![]() |
Eaton MTL7741 Intrinsic Safety Barrier for ATEX Digital Input 24V DC Output |
![]() |
Inductive SIL3 PLC MTL Barriers Instruments Universal Transducer Interface MTL4544 |
![]() |
24V 35mA MTL5516C MTL Safety Barrier Instruments Switch Proximity Detector Interface |