| Category | Project | Content |
|---|
| System | System structure | 1 control cabinet + 1 feedback load cabinet |
| Overall size | 1600*1000*2050mm |
| Total floor area | 1600*1800mm (Including operation area) |
| Total input voltage | Three-phase five-wire system 380Vac (rated) |
| Total input current | 182A |
| Total input power | System power 120kW |
| Application ambient temperature | 0-40℃ |
| Application environment humidity | 0-95% |
| Fire protection requirements | Materials meet UL 94V0 rating |
| Environmental requirements | Materials comply with Rohs, WEEE requirements |
| Safety requirements | Comply with IEC62368 international standard design requirements |
| Burn-in Cabinet | Units/Cabinet | N bits/N cabinet |
| Burn-in product DC power | 120kW/bit |
| Burn-in product DC voltage | 200-1000Vdc |
| Burn-in product DC current | 250A/bit |
| Burn-in product AC power | 120kW/bit |
| Burn-in products AC voltage | 220/380Vac/50Hz Three-phase five-wire |
| Burn-in product AC current | 300A/bit |
| AC Connector Type | PA350 (L1/L2/L3/N/PE) |
| DC Connector Type | DC bronze medal |
| Signal Connector Type | RJ45 (network port) |
| Input power | 120kW |
| Feedback power | ≥90% |
| Volume size | 800*800*2050mm |
| Product area air duct direction | Forward wind, upward wind |
| Cooling method | Air cooling |
| Material | Cold rolled sheet |
| Monitoring Software | Display accuracy | ±(1%+0.2%FS) |
| Control precision | ±(1%+0.2%FS) |
| Bad way of reporting | Audible alarm |
| Report format | CSV format |
| Control Cabinet | Output Power | 120kW |
| Control system | Windows 10 |
| Display medium | Computers and Monitors |
| Manipulating medium | Mouse and keyboard |
| Communication method | Cable |
| Type of protection | Over current, leakage, over temperature, smoke, emergency stop |
| Alarm method | Sound and light alarm, remote network |
| Heat dissipation type | Air cooling |
| Maintenance mode | Post maintenance |
| Volume size | 880*860*2050mm |