Electronic Cigarette / Notebook Lithium Battery Charging And
Discharging burning-in Test Equipment Scope of Application This specialized equipment is engineered for comprehensive lithium
battery module burn-in testing systems, providing reliable
performance validation for electric vehicle applications. Performance Parameters | Parameter | Specification Requirements |
|---|
| Burn-in Cabinet Size | L2600 * W1320 * H1980 (mm) | | Distribution Cabinet Size | L600 * W1320 * H1980 (mm) | | Electrical Design | - Incoming line: three-phase 380V / 68A
- Power distribution: AC output adopts three-phase five-wire system,
single-phase voltage supplies power to the power module, with
three-phase equalization in layers
- Control: power output of each layer can be monitored and controlled
| | Cabinet Layout & Design | - Overall layout: aging cabinet contains product area and isolation
module area with complete isolation
- Product area: 6 layers, 3 slots per layer, 1 PSU per layer, 6
isolation modules
- Connection method: hard connection with fixed external interfaces
including power supply output, load input, 485 signal, and address
signal
- Heat capacity design: 13.5kW (2.25kW * 6)
| | Monitoring System | - PC: supports multiple 485 serial communication, Windows 7 system,
500GB hard disk
- Includes 22-inch monitor, mouse, keyboard, wireless barcode gun
- General monitoring: 1-way 485 communication with PC, 4-way
downstream 485 communication with monitoring subsystems
- PSU monitoring: monitors each power supply module through 485
serial communication
- Load isolation module monitoring: monitors each isolation module
through 485 communication
- Power environment monitoring: individual control of each layer
power supply and fan switches
| | Software Capabilities | - 485 receives commands from host computer and monitors power modules
through CAN
- Implements output voltage and current limit setting commands
- Manages voltage, current, temperature, smoke status information
queries
- Comprehensive management of power module monitoring, load
isolation, cabinet environment, and product testing
- Real-time abnormality handling, parameter adjustment, control
restart/reset, and alarm recording
| | Safety & Protection Features | - Cabinet smoke and over temperature protection systems
- Heat dissipation: single load cabinet product area has 6KW heat
dissipation capacity
- Leakage protection: 30mA leakage protection circuit breaker
installed on AC side
- Comprehensive fire prevention and emergency protection functions
|
All specifications and safety features are designed to meet
industry standards and ensure reliable, safe operation during
lithium battery module burn-in testing procedures.
|