| System | System structure | 1 control cabinet + 2 burn-in cabinets + 4 trolleys |
| Overall size | 3800*1800*1900mm |
| Total floor area | 3800*2500mm(Including operation area) |
| Total input voltage | Three-phase five-wire system 220Vac (rated) |
| Total input current | 200A |
| Total input power | 100kW |
| Application ambient temperature | 0-40℃ |
| Application environment humidity | 0-95% |
| Fire protection requirements | Materials meet UL 94V0 rating |
| Burn-in cabinet | Burn-in bits/cabinet | 16 bits/cabinet |
| Burn-in product power | 18kw/bits |
| Burn-in product input voltage | 220Vac (single phase)/380Vac (three phase) |
| Burn-in product input current | 32A/bit |
| Burn-in Product Load Category | 15kW/bit |
| Burn-in product load current | 100-800Vdc |
| Power Connector Type | Gb DC charging interface |
| Signal Connector Type | RJ45 |
| Input power | 288kW |
| Feedback power | 240kW |
| Volume size | 2050*600*1900mm |
| Dimensions in the product area | 1800*1600mm |
| Product area layers | 4th floor |
| Bit space size | 450*420mm |
| Minimum floor height | 250mm |
| Trolley | Volume size | 1900*500*1900mm |
| Layer spacing | 420mm |
| Load bearing | 800kg |
| Mobile way | Casters |
Monitoring software | Display running information | Input voltage, current, power, output voltage (DC source module communication or product communication) |
| Show status information | Not Connected / Vacant / Passed / Under Voltage / Under Current /
Over Voltage / Over Current / No Output / Protection |
| Bad way of reporting | Audible alarm |
| Report format | CSV format |
| Statistics | Yield/CPK/Time Distribution |
| MES docking | Support |
| Scan speed | 5S |
Control cabinet | Manipulating medium | Mouse and keyboard |
| Communication method | Cable |
| Type of protection | Over current, leakage, over temperature, smoke, emergency stop |
| Alarm method | Sound and light alarm, remote network |
| Maintenance mode | Post maintenance |
| Material | 1.5mm cold rolled sheet |
| Volume size | 880*860*1900mm |