| System | System structure | 1 control cabinet + 6 load cabinets |
| Overall size | 5800*860*2050mm |
| Total floor area | 5800*1800mm(including operation area) |
| Total input voltage | Three-phase five-wire system 220Vac (rated) |
| Total input current | 200A*6 |
| Total input power | 100kW*6 |
| Application ambient temperature | 0-40℃ |
| Application environment humidity | 0-95% |
| Fire protection requirements | Materials meet UL 94V0 rating |
| Environmental requirements | Materials comply with Rohs, WEEE requirements |
| Safety requirements | Comply with IEC62368 international standard design requirements |
| Burn-in cabinet | Burn-in bits/cabinet | 16 bits/cabinet |
| Burn-in bits/layer | 4 bits/layer |
| Burn-in product power | 150kW/bit |
| Burn-in product input voltage | 380Vac/Three Phase |
| Burn-in product input current | 250A/bit |
| Burn-in Product Load Category | 132kW/bit |
| Burn-in product load current | 100-1000Vdc |
| Auxiliary voltage of Burn-in products | 430A/bit 250A/bit |
| AC Connector Type | PA350 (L1/ L2/ L3/N/PE) |
| DC Connector Type | REMA630 GB DC Charging Gun Holder |
| Signal Connector Type | RJ45 |
| Bit Status Indicator | No |
| Input power | 600kW |
| Feedback power | 500kW |
| Volume size | 800*800*2050mm |
| Air duct direction | Forward wind, upward wind |
| Cooling method | Air cooling |
| Material | 1.5mm cold rolled sheet |
Monitoring software | Display running information | Input voltage, current, power, output voltage(DC source module
communication or product communication)
|
| Show status information | Not Connected / Vacant / Passed / Under Voltage / Under Current /
Over Voltage / Over Current / No Output / Protection
|
| Display accuracy | ±(1%+0.2%FS) |
| Control precision | ±(1%+0.2%FS) |
| Bad way of reporting | Audible alarm |
| Report format | CSV format |
| Statistics | Yield/CPK/Time Distribution |
| MES docking | Support |
| Scan speed | 5S |
| Control cabinet | Control system | Window 10 |
| Display medium | Computers and Monitors |
| Manipulating medium | Mouse and keyboard |
| Communication method | Cable |
| Type of protection | Over current, leakage, over temperature, smoke, emergency stop |
| Alarm method | Sound and light alarm, remote network |
| Heat dissipation type | Air cooling |
| Maintenance mode | Post maintenance |
| Material | 1.5mm cold rolled sheet |
| Volume size | 880*860*1900mm |