S1500 ICU VENTILATOR Application Our oxygen machine in ICU demonstrates exceptional performance in
various medical settings such as operation rooms, ICU departments,
and emergency treatment units. It is specifically designed to
assist or substitute spontaneous breathing for adult, pediatric,
and neonatal patients. With over 25 years of experience in the
market, we have established ourselves as experts in the field of
ventilators, providing professional and reliable solutions that
meet all your ventilation requirements. The S1500 ventilator, our breathing machine used in icu, has
quickly gained popularity in the market due to its flexible
configuration, outstanding quality, and competitive price. It has
become a true superstar in the industry, trusted by healthcare
professionals worldwide. Whether it's in critical surgeries, intensive care units, or
emergency situations, our ventilator delivers exceptional
performance, ensuring optimal patient care and support. We
prioritize the safety and comfort of patients, and our ventilator
is equipped with advanced features and precise controls to meet the
demanding needs of medical professionals. ICU Nurse Ventilator Safety - 14 types of sound and visual alarm information, easier for users to
do some error checking and troubleshooting.
- Built-in oxygen concentration sensor, ensure stable precision of
oxygen concentration.
- Easy to move with four casters, easy to stop with two brakes.
- Separate design of electronic circuit and gas flow rate keep safe
running of ventilator.
- Compact long life internal battery can provide emergency power,
avoid risk of patient.
- Self-check before operation, eliminate system mistake.
| | Friendly interface | Humidifier | Oxygen sensor | 12.1" TFTT LCD screen display, screen saver mode. 14 types of alarm and protection function. 2 of 3 oscillgraphs can be displayed on the screen at the same time. Fast oxygen supply. | Heat and wet breathing gas, makes it more comfortable for patient to breathe in. 3 types of humidifier for your choices: one with thermometer for standard, one with digital shown for option, another one has have dual pipeline heating function and servo control function for option. | Built-in oxygen concentration sensor, ensure stable precision of oxygen concentration. |
Air compressor Automatic detection and switch of central gas, cylinder gas supply
or air compressor. Make low noise, create quiet environment for doctors and patients. Longer service life and waterproof material. Digital show for parameters, easier and clearer for users know
real-time condition. | | Caster Easy to move with 4 casters,easy to stop with 2 brakes. | Breathing circuit High temperature resistance breathing piplines is reusable and anti-polution. | |
| Ventilator parameter range | | Tidal volume (Vt) | 0, 20 ~ 2000 mL | | Frequency (Freq) | 1 min ~ 100 min | | Oxygen concentration | 21 % ~ 100 % | | I:E | 4 : 1 ~ 1 : 8 | | PEEP | 0 cmH2O ~ 40 cmH2O | | Pressure triggering sensitivity (Ptr) | -20 cmH2O ~ 0 cmH2O (Based on PEEP) | | Flow trigger sensitivity (Ftr) | 0.5 L/min ~ 30 L/min | | SIGH | 0 (off) 1/100 ~ 5/100 | | Apnea ventilation | OFF, 5 s ~ 60 s | | Monitoring parameter | | Frequency (Freq) | 0/min ~ 100/min | | Tidal volume (Vt) | 0 mL ~ 2500 mL | | MV | 0 L/min ~ 99 L/min | | Airway pressure | 0 cmH2O ~ 100 cmH2O | | Dynamic lung compliance monitoring | 1 mL/cmH2O ~ 1000 mL/cmH2O | | Oxygen concentration | 15 % ~ 100 % | | Alarm and protection | | AC power failure alarm | Power failure or no connection | | Internal backup battery low voltage alarm | ≤ 11.3 ± 0.3 V | | No tidal volume | No tidal volume within 6 s | | High minute volume alarm | 5 L/min ~ 99 L/min | | Low minute volume alarm | 1 L/min ~ 30 L/min | | High airway pressure alarm | 20 cmH2O ~ 100 cmH2O | | Low airway pressure alarm | 0 cmH2O ~ 20 cmH2O | | High oxygen concentration alarm | 19 % ~ 100 % | | Low oxygen concentration alarm | 18 % ~ 99 % | | Continuous pressure alarm | (PEEP + 1.5 cmH2O) over 16s | | Suffocation warning | 5 ~ 60 s | | Fan error | Show on screen | | Oxygen deficit | Show on screen | | The maximum limited pressure | < 12.5 kPa | | Working condition | | Gas source | O2, Air | | Pressure | 280 kPa - 600 kPa | | Voltage | 220 V ± 22 V | | Power frequency | 50 Hz ± 1 Hz | | Input power | 900 VA(With air compressor) | | 250 VA(Without air compressor) | | Oscillogram | Wooden case packing size | | P-T(Pressure-Time) | Main engine : L 560 * W 560 * H 615 mm | | F-T(Flow-Time) | G.W. : 32 KG N.W.: 17 KG | | P-V Loop(Pressure-Volume Loop) | Air compressor : L 685 * W 690 * H 1140 mm | | | G.W. : 98 KG N.W. : 63 KG |
|