S1200 ICU VENTILATOR Icu Oxygen Machine Application The ICU oxygen machine makes a good performance in operation room,
ICU department and emergency treatment. It used to assist or replace the sponta-neous breathing for adult,
pediatric and neonatal patient. 23 years of experience in Market-oriented ventilator make us
professional and reliable, satisfy all your need in ventilation.
Due to the flflexible confifiguration, good quality and competitive
price, the S1200 has soon become the superstar of market. Features - Multiple ventilation modes, suitable for ICU, emergency department
and operation room etc: (PRVC, APRV, DUOLEVEL, IPPV, PCV, PSV,
- V-SIMV, P-SIMV,V-A/C, P-A/C, SPONT/CPAP, SIGH, MANUAL)
- Pressure and flow dual triggering mechanism make patient brea the
better and more comfortable.
- Rapid oxygen supply, automatically offer high flow rate oxygen
within two minutes.
- Pressure-Time, Flow-Time, Volume-Time, ETCO2 -Time oscillogram,
real-time display the condition of patient in all respects.
- Separate design of electronic circuit and gas flow rate keep safe
running of ventilator.
- Compact long life internal battery can provide emergency power,
avoid risk of patient.
- Three level alarm system display overall condition of machine,
easier for users to find and solve problems according to
indication.
- Oscillogram freezing and recovery offer doctors a better
understanding of the real-time situation for patient.
- Self-check before operation, ensure every port of machine is in
good condition.
Safety - 14 types of sound and visual alarm information, easier for users to
do some error checking and troubleshooting.
- Built-in oxygen concentration sensor, ensure stable precision of
oxygen concentration.
- Easy to move with four casters, easy to stop with two brakes.
- Separate design of electronic circuit and gas flow rate keep safe
running of ventilator.
- Compact long life internal battery can provide emergency power,
avoid risk of patient.
- Self-check before operation, eliminate system mistake.
Friendly interface 15" TFT LCD screen display screen saver mode. 14 types of alarm and protection function. 3 of 5 oscillographs can be displayed on the screen at the same
time. 5 oscillograms for your choice, 3 of them can be displayed on the
screen at the same time. | | Air compressor Automatic detection and switch of central gas, cylinder gas supply
or air compressor. Make low noise, create quiet environment for doctors and patients. Longer service life and waterproof material. Digital show for parameters, easier and clearer for users know
real-time condition. | | Caster Easy to move with 4 casters,easy to stop with 2 brakes. | Humidifier Heat and wet breathing gas, makes it more comfortable for patient
to breathe in. 3 types of humidifier for your choices: one with thermometer for standard, one with digital shown for option, another one has have
dual pipeline heating function and servo control function for option. | | Nebulization function Make medicine into small liquid and particle, easier and quicker
for patient to breathe in. | Oxygen sensor Built-in oxygen concentration sensor, ensure stable precision of
oxygen concentration. | Breathing circuit High temperature resistance breathing piplines is reusable and anti-polution. | |
| Ventilation mode | PRVC, APRV, DUOLEVEL, IPPV, PCV, PSV, V-SIMV, P-SIMV, V-A/C, P-A/C, SIGH, SPONT/CPAP, MANUAL | | | | | | Ventilator parameter range | | Tidal volume (Vt) | 0, 20 ~ 2000 mL | | Frequency (Freq) | 1 min ~ 100 min | | Oxygen concentration | 21 % ~ 100 % | | I:E | 4 : 1 ~ 1 : 8 | | PEEP | 0 cmH2O ~ 40 cmH2O | | Pressure triggering sensitivity (Ptr) | -20 cmH2O ~ 1000 cmH2O (Based on PEEP) | | Monitoring parameter | | Frequency (Freq) | 0/min ~ 100/min | | Tidal volume (Vt) | 0 mL ~ 2500 mL | | MV | 0 L/min ~ 99 L/min | | Airway pressure | 0 cmH2O ~ 100 cmH2O | | Dynamic lung compliance monitoring | 1 mL/cmH2O ~ 1000 mL/cmH2O | | Oxygen concentration | 15 % ~ 100 % |
| Alarm and protection | | AC power failure alarm | Power failure or no connection | | Internal backup battery low voltage alarm | ≤ 11.3 ± 0.3 V | | No tidal volume | No tidal volume within 6 s | | High minute volume alarm | 5 L/min ~ 99 L/min | | Low minute volume alarm | 1 L/min ~ 30 L/min | | High airway pressure alarm | 20 cmH2O ~ 100 cmH2O | | Low airway pressure alarm | 0 cmH2O ~ 20 cmH2O | | High oxygen concentration alarm | 19 % ~ 100 % | | Low oxygen concentration alarm | 18 % ~ 99 % | | Continuous pressure alarm | (PEEP + 1.5 cmH2O) over 16s | | Suffocation warning | 5 ~ 60 s | | Fan error | Show on screen | | Oxygen deficit | Show on screen | | The maximum limited pressure | < 12.5 kPa | | | | | Working condition | | Gas source | O2, Air | | Pressure | 280 kPa - 600 kPa | | Voltage | 220 V ± 22 V | | Power frequency | 50 Hz ± 1 Hz | | Input power | 900 VA(With air compressor) 250 VA(Without air compressor) |
| Oscillogram | Wooden case packing size | | P-T (Pressure-Time) | Main engine : 560 * 560 * 615 mm | | F-T (Flow-Time) | G.W. : 30 KG N.W. : 15 KG | | V-T (Volume-Time) | Air compressor : 685 * 690 * 1140 mm | | ETCO2 -T (End-Tidal CO2 -Time) | G.W. : 138 KG N.W. : 63 KG | | P-V Loop (Pressure-Volume Loop) | | | F-V Loop (Flow-Volume Loop) | | | P-F Loop (Pressure-Flow Loop) | |
|