Low Temperature Ent Surgery Instruments ENT Probe For Snoring Treatment System

Brand Name DaMai/Vanway
Model Number VF06E
Certification ISO,CFDA
Place of Origin China
Minimum Order Quantity 1
Price negotialble
Payment Terms T/T,L/C,Western Union
Supply Ability 10000000
Delivery Time 3-5 days
Packaging Details carton
Application Tonsillectomy, Adenoidectomy, CAUP, UPPP
Advantage Minimally Invasive, Low Temperature
Usage Ablation, Cutting, Resection, Hemostasis
Valid Time 3 Years
Highlight ent surgical instruments, portable plasma wand
Feature Disposable Coblation
Detailed Product Description

Tonsillectomy Plasma Wand ENT Probe For Snoring Treatment System

 

Product Introduction

 

VF06E is design specially for Tonsillectomy, Adenoidectomy, CAUP, UPPP treatment. It is suitable for the length of the blade required for tonsil and adenoid surgery. During adenoidectomy, it is easier to access the hyperplasia tissue in the posterior nostril, and the blade is easier to bend. It has the function of cutting, ablation, hemostasis and coagulation. It is connect with PK100 ENT plasma surgery system to perform the operation.

 

Product Tip Picture

 

 

Product Application

 

  • Repeated acute attacks of chronic tonsillitis;
  • A history of abscesses around the tonsils;
  • Excessive hypertrophy of the tonsils, preventing swallowing or breathing, or affecting eustachian tube function;
  • simple III degree hypertrophy or near III degree hypertrophy tonsils;
  • Patients with rheumatic fever, nephritis, arthritis, and rheumatic heart disease who have suspected tonsils as the lesion;
  • Benign tonsil tumors.

 

Product Advanatages

 

  • Safety: Compared with traditional surgical methods (such as: electric knife, laser), the current does not flow through the human body, the working surface temperature is only 40 ° C to 70 ° C, and the surrounding tissue is less thermally damaged. When used in the recommended energy range, the cutting and ablation depth is controlled to ≤50μm.
  • Minimally Invasive: Compared with traditional surgical methods (such as electric knife, laser), it has less heat, reduces tissue thermal damage, reduces wound healing time, reduces wound bleeding and scar formation
  • High Efficiency: Compared with traditional surgical methods (such as: electric knife, laser), the patient's pain during surgery is significantly reduced, and the incidence of postoperative inflammation is significantly reduced. During the surgery, the doctor stops bleeding while cutting, and does not need other hemostasis tools.

 

System Set Up

 

DescriptionRemark
Manufacturer LogoVanway Brand.
Working Frequency50Hz
Receptacle of FootswitchConnects with Footswitch which determines ablation or coagulation mode.
Receptacle of Treatment HandleConnects with the treatment accessories.
Power SwitchSystem start power button. “O” means power off; “I” means power on.
ABLATION mode SelectorSelect ABLATION mode 1 or 2 Output waveform.
Indicator of Treatment Probe ConnectionLED turns on green when the probe cable is connected and turns on red when it is not connected.
Indicator of Footswitch ConnectionLED turns on green when the footswitch cable is connected and turns on Red when it is not connected.
ABLATION Power Setting Display

Shows the preset ABLATION output value in two digits.

“01” with Min. power output, and “10” with the highest output.

Ablation Output Power Up/Down ButtonThe number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode.

 

 

Anesthesia

 

General anesthesia

 

Cutting Principle

 

Relying on the mechanical kinetic energy of the plasma in the electric field, it hits the molecular bonds (40-70 ° C) of the target tissue to lyse and ablate. The thermal damage depth is less than 0.5mm, and the trauma to normal adjacent tissues is small.

 

Treatment Diseases 

 

Tonsillectomy, Adenoidectomy, CAUP, UPPP

 

Storage Condition

 

Electrodes shall be stored in environment of humidity less than 80%. no corrosive gas, well vented room. Taking complete protection to electrodes.

 