High Temperature 1550°C DSC Differential Scanning Calorimeter BXT-DSC-1550
|
|
BAXIT High Temperature Differential scanning calorimeter Instrument introduction Differential scanning calorimeter (heat flow DSC) is a classic thermal analysis method of thermal effects under controllable program temperature. It is used in the research and development, process optimization, quality control and failure analysis of various materials and chemistry fields. It has been widely used in various occasions. Using the DSC method, we can study the phase transition of inorganic materials, the melting of polymer materials, the crystallization process, the polymorphism of drugs, the solid/liquid ratio of foods such as oils and fats. Instrument use Measure physical and chemical changes related to heat, such as glass transition temperature, melting point, melting temperature, crystallization and crystallization heat, phase transition reaction heat, product thermal stability, solidification/crosslinking, oxidation induction period, etc. To Main features The closed ceramic insulation furnace body structure greatly improves signal sensitivity and resolution, and can obtain a more stable baseline. Equipped with an imported high-frequency core control processor, the processing speed is faster and the control is more efficient. The sensor is designed with imported materials and equipped with K-type or E-type sensors that can be switched freely through software. The sensor type can be flexibly selected for different testing scenarios, especially suitable for phase transition and vitrification experiments on polymer materials. Independent atmosphere control can be achieved through software intelligent settings, and the instrument can automatically switch the gas path system, resulting in higher experimental efficiency. The lower and upper computers of the equipment system have multi-point temperature correction functions, which meet the needs of different experimental scenarios and improve the accuracy of temperature testing. It has two experimental modes, FTC and STC, which can be set for more friendly and flexible temperature control, meeting the needs of different application scenarios and experiments. The temperature control during the experimental process is more accurate, the analysis of sensor signals is more efficient, and the experimental effect is accurately controlled. The fully temperature control system adopts an optimized dynamic PID algorithm, which greatly avoids the shortcomings of traditional PID algorithms and improves the robustness of dual-mode temperature control. The 12 step program temperature control setting makes the experimental methods more diversified, and the equipment has a cyclic scanning function, with a maximum of 9999 cyclic scanning times set and data automatically saved. The sampling frequency of the sensor signal can be set between 1-10Hz, making the experimental method more flexible and the data more controllable. The design concept of dual temperature sensors allows for simultaneous testing of both the internal temperature of the furnace and the sample temperature. The equipment system can conduct experiments on materials related to heating, cooling, and isothermal processes. The instrument adopts USB bidirectional communication, software intelligent design, baseline deduction function, automatic drawing of experimental process, and intelligent processing of various data, such as glass transition temperature, oxidation induction period, melting point and crystallization of substances, etc. Technical parameters
Reference standards GB/T 19466.3-2004 / ISO 11357-3: 1999 Part 3: Determination of melting and crystallization temperature and enthalpy; |
|
Liquid nitrogen refrigeration -170~600°C Differential Scanning Calorimeter DSC Analyzer |
|
High Temperature 1550°C DSC Differential Scanning Calorimeter BXT-DSC-1550 |
|
High Temperature 1250°C DSC Differential Scanning Calorimeter OIT Tg DTA Analyzer |
|
-40~600°C Low Temperature Differential Scanning Calorimeter Glass Transition Temperature Tg DSC Analyzer |
|
DSC Analyzer Differential Scanning Calorimeter Glass Transition Temperature Tg |
|
Laboratory 600°C 2000mW Tg Tga Dta Differential Scanning Calorimeter Oxidation Induction Time OIT DSC Analyzer |