High Temperature 1550°C DSC Differential Scanning Calorimeter BXT-DSC-1550

Temperature repeatability ±0.1℃
Temperature control method heating, constant temperature 、cooling (full program automatic control)
DSC range 0~±2000mW
Precision ±0.001μV
Temperature range RT~1550℃
Sensitivity 0.001μV
Heating rate 0.1~80℃/min
Sensor type K-type and E-type can be switched freely (K-type standard, E-type optional)
Power supply AC 220V 50Hz
Brand Name BAXIT
Model Number BXT-DSC-1550
Certification CE
Place of Origin China
Minimum Order Quantity 1
Price USD11428/unit
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000PCS / Month
Delivery Time 5 working days
Packaging Details Wooden
Temperature accuracy 0.01℃
Scan type Heating, cooling, isothermal scanning
Temperature fluctuation ±0.01℃
Program temperature control Flexible setting of 12 stage temperature control throughout the entire stage
Timing frequency 16.6Hz
Detailed Product Description

BAXIT High Temperature Differential scanning calorimeter

Instrument introduction

Differential scanning calorimeter (heat flow DSC) is a classic thermal analysis method of thermal effects under controllable program temperature. It is used in the research and development, process optimization, quality control and failure analysis of various materials and chemistry fields. It has been widely used in various occasions. Using the DSC method, we can study the phase transition of inorganic materials, the melting of polymer materials, the crystallization process, the polymorphism of drugs, the solid/liquid ratio of foods such as oils and fats.

Instrument use

Measure physical and chemical changes related to heat, such as glass transition temperature, melting point, melting temperature, crystallization and crystallization heat, phase transition reaction heat, product thermal stability, solidification/crosslinking, oxidation induction period, etc. To

Main features

The closed ceramic insulation furnace body structure greatly improves signal sensitivity and resolution, and can obtain a more stable baseline.

Equipped with an imported high-frequency core control processor, the processing speed is faster and the control is more efficient.

The sensor is designed with imported materials and equipped with K-type or E-type sensors that can be switched freely through software. The sensor type can be flexibly selected for different testing scenarios, especially suitable for phase transition and vitrification experiments on polymer materials.

Independent atmosphere control can be achieved through software intelligent settings, and the instrument can automatically switch the gas path system, resulting in higher experimental efficiency.

The lower and upper computers of the equipment system have multi-point temperature correction functions, which meet the needs of different experimental scenarios and improve the accuracy of temperature testing.

It has two experimental modes, FTC and STC, which can be set for more friendly and flexible temperature control, meeting the needs of different application scenarios and experiments. The temperature control during the experimental process is more accurate, the analysis of sensor signals is more efficient, and the experimental effect is accurately controlled.

The fully temperature control system adopts an optimized dynamic PID algorithm, which greatly avoids the shortcomings of traditional PID algorithms and improves the robustness of dual-mode temperature control.

The 12 step program temperature control setting makes the experimental methods more diversified, and the equipment has a cyclic scanning function, with a maximum of 9999 cyclic scanning times set and data automatically saved.

The sampling frequency of the sensor signal can be set between 1-10Hz, making the experimental method more flexible and the data more controllable.

The design concept of dual temperature sensors allows for simultaneous testing of both the internal temperature of the furnace and the sample temperature.

The equipment system can conduct experiments on materials related to heating, cooling, and isothermal processes.

The instrument adopts USB bidirectional communication, software intelligent design, baseline deduction function, automatic drawing of experimental process, and intelligent processing of various data, such as glass transition temperature, oxidation induction period, melting point and crystallization of substances, etc.

Technical parameters

Temperature rangeRoom temperature~1550℃
Range of measurement0~±2000μV
Precision±0.001μV
Sensitivity0.001μV
Heating rate0.1~80℃/min
Temperature accuracy0.01℃
Temperature resolution0.01℃
Temperature fluctuation±0.01℃
Temperature repeatability±0.1℃
Sensor typeK-type and E-type can be switched freely (K-type standard, E-type optional)
Timing frequency16.6Hz
Experimental modeFTC and STC can be set arbitrarily
Program temperature controlFlexible setting of 12 stage temperature control throughout the entire stage
Temperature control methodHeating,constant temperature ,cooling
Scan typeHeating, cooling, isothermal scanning
Number of scansThe number of cycle scans can be set up to 9999 times, and the data is automatically saved
Atmosphere controlTwo atmospheres can be freely set, and the instrument automatically switches between them
Display mode24bit color 7-inch LCD touch screen display
Data interfacestandard USB interface
Sampling rate1-10Hz programmable settings
Instrument calibrationThe lower computer and upper computer both have multi-point temperature correction function
Parameter standardEquipped with standard substances, users can self correct temperature and enthalpy
Power supplyAC 220V/50Hz or customized

Reference standards

GB/T 19466.3-2004 / ISO 11357-3: 1999 Part 3: Determination of melting and crystallization temperature and enthalpy;