Custom Built 25 kVA Single Phase Pad Mounted Distribution
Transformer for Community Power Distribution Product Overview This 25 kVA single phase pad mounted distribution transformer is an
outdoor rated, liquid filled power distribution unit engineered for
reliable, long term performance in community power distribution
networks. Its compact, compartmental type enclosure is designed for
ground level installation on a concrete pad, eliminating the need
for a dedicated substation building and making it well suited for
residential subdivisions, light commercial zones, and rural
electrification projects. Manufactured as a custom built solution,
every unit is configured to match the end user's specific primary
voltage, secondary voltage, and local utility criteria. Key Attributes - Efficiency Optimized with Low Loss Core and Winding Design - The transformer utilizes premium grain oriented silicon steel
cores and high conductivity copper or aluminum windings, achieving
low no load and load loss values that meet or exceed DOE 2016
efficiency criteria across the full 15 to 167 kVA single phase
range. This translates directly into reduced operational energy
costs over the transformer's service life.
- Robust Outdoor Construction for All Weather Reliability - Built with a heavy gauge steel enclosure featuring a high
durability outdoor coating system, this pad mounted transformer
withstands prolonged exposure to sunlight, rain, humidity, and
temperature extremes. The sealed tank construction keeps moisture
and contaminants out, while the liquid immersed design provides
consistent cooling performance even in high ambient temperature
environments.
- Custom Built Voltage Configuration for Regional Grid Compatibility - Every unit is built to order with customizable primary voltage
ratings up to 34.5 kV and secondary voltages including 120/240V
split phase, 240/480V, and 277V. This flexibility allows seamless
integration with the diverse distribution standards found across
North America, Central America, and South America, eliminating the
need for costly auxiliary voltage conversion equipment.
- Enhanced Safety and Low Maintenance Ground Level Installation - The dead front, tamper resistant design isolates all energized
parts within a locked, grounded compartment, significantly
improving public safety in populated areas. The ground level pad
mount configuration simplifies routine inspection and maintenance
tasks without requiring confined space entry or heavy lifting
equipment, reducing long term operational costs.
- Meets Stringent ANSI IEEE and DOE Efficiency Criteria - The transformer is designed, tested, and manufactured in
accordance with ANSI IEEE C57.12.38 and DOE 2016 energy
conservation standards, offering verified performance and
reliability. Documentation such as certified test reports and
material traceability records is provided with each shipment to
support utility acceptance and project audits.
Technical Specifications | Rated Power | 25 kVA single phase |
|---|
| Frequency | 60 Hz, 50 Hz available upon request |
|---|
| Cooling Method | ONAN, oil immersed self cooled |
|---|
| Insulating Fluid | Mineral oil standard; natural ester fluid optional for enhanced
environmental performance |
|---|
| Primary Voltage Ratings (Customizable) | 4160GrdY/2400, 12470GrdY/7200, 13200GrdY/7620, 24940GrdY/14400,
34500GrdY/19920, and other voltages up to 34.5 kV |
|---|
| Secondary Voltage Ratings (Customizable) | 120/240V split phase, 240/480V, 277V |
|---|
| Tapping Range | Typically plus or minus 2 by 2.5 percent no load tap changer
accessible from the low voltage compartment |
|---|
| Winding Material | Copper or aluminum, selectable at time of order |
|---|
| Core Material | High permeability grain oriented silicon steel |
|---|
| Enclosure Type | Dead front, compartmentalized pad mount, heavy gauge steel with
weather resistant coating |
|---|
| Bushing Configuration | Primary and secondary bushings located in separate lockable
compartments per ANSI IEEE C57.12.38 |
|---|
| Efficiency | Meets or exceeds DOE 2016 efficiency requirements for single phase
distribution transformers |
|---|
| Standards | ANSI IEEE C57.12.38, NEMA, and other regional standards available
upon request |
|---|
| Ingress Protection | Sealed tank construction suitable for outdoor installation in harsh
environments |
|---|
Solution Highlights for the Americas and Latin America - Voltage Adaptability for Diverse Grid Systems - Recognizing that distribution voltages vary considerably across
the Americas, from 7200V and 14400V in North America to 7620V and
19920V in parts of Latin America, this transformer is offered with
a wide range of customizable primary voltages. This design
eliminates the need for field modifications and ensures immediate
grid compatibility upon delivery.
- High Humidity and Tropical Climate Resilience - Engineered for the hot and humid environments typical of Central
and South American coastal regions, the sealed tank design and high
grade insulating fluid prevent moisture ingress, while the oil
immersed ONAN cooling method maintains stable operating
temperatures even under continuous full load in high ambient
conditions.
- Enhanced Safety for Public Access Areas - The dead front, lockable compartment construction meets the
stringent public safety expectations of North American utilities
and the growing safety awareness in Latin American urban
developments. All live parts are fully enclosed, reducing risks in
community settings such as residential subdivisions, school
campuses, and commercial plazas.
- Ready for Distributed Solar and Renewable Integration - With the rapid growth of rooftop solar in countries like Brazil,
Mexico, and Chile, the transformer's 120/240V split phase and
240/480V secondary options can readily connect with single phase
solar inverters. The unit's low loss design also supports
bidirectional power flow, helping communities reduce energy costs
while maintaining grid stability.
- Simplified Logistics and Remote Site Installation - The compact pad mount design and moderate weight streamline
containerized ocean freight and truck delivery to remote locations
across the Andes, Amazon basin, and rural North American towns. The
ground level installation requires only a flat concrete pad and
standard lifting gear, allowing local crews to complete placement
quickly without specialized substation equipment.
Frequently Asked Questions - What is the typical lead time for a custom built 25 kVA pad mounted
transformer?
Lead times vary based on configuration and order volume. For
standard voltage combinations and mineral oil filling, production
typically completes within 30 to 45 working days. Units requiring
less common voltages or natural ester fluid may require additional
time. Rush orders can be discussed with our production team. - Can this transformer be supplied with both copper and aluminum
windings?
Yes, both copper and aluminum winding options are available. Copper
windings offer higher electrical conductivity and are often
specified for projects prioritizing efficiency and longevity.
Aluminum windings provide a lighter weight and more economical
alternative while still meeting all applicable performance
standards. - Which certifications and test reports are provided with the unit?
Each transformer comes with a routine test report documenting
insulation resistance, winding resistance, voltage ratio, no load
loss, load loss, and dielectric strength test results. Units
destined for the United States and Canada can be supplied with UL
or CSA certification when requested at the time of order. Standard
units meet ANSI IEEE C57.12.38 and DOE 2016 requirements. - Is this transformer suitable for coastal areas with high salt spray
and humidity?
Absolutely. The heavy gauge steel enclosure with weather resistant
coating and the sealed, oil filled tank design protect internal
components from moisture, salt, and corrosive elements. This
construction has been proven effective in tropical and coastal
zones throughout Latin America and the Caribbean. - What foundation preparation is needed for installation?
A level concrete pad capable of supporting the transformer's weight
is the primary requirement. The pad should be placed on firm, well
drained soil. Once the pad is cured, the transformer can be set in
place using standard lifting lugs or forklift access, connected to
the incoming and outgoing cables, and immediately energized
following a final inspection. - Do you offer replacement units for existing network transformers
with specific dimensional constraints?
Yes. Because we manufacture on a build to order basis, we can
adjust enclosure dimensions and bushing placements to match the
footprint of many legacy pad mounted transformers. Providing the
original nameplate data or a simple field measurement diagram
allows us to produce an electrically equivalent replacement that
fits the existing foundation without costly site modifications.
Request a quote today to receive your custom 25 kVA single phase
pad mounted transformer configuration with a detailed specification
sheet and current pricing.
|