Maintenance Free Safe 250kVA 11kV to 0.4kV Dry Type Distribution Transformer for Server Room Power Distribution
|
|
Maintenance Free Safe 250kVA 11kV to 0.4kV Dry Type Distribution
Transformer for Server Room Power Distribution Product Overview Engineered for the strict demands of digital infrastructure, this 250kVA 11kV to 0.4kV dry type distribution transformer provides a dedicated power step-down solution within server rooms and IT facilities. Its epoxy-resin encapsulated high-voltage coils eliminate fire and leakage risks associated with liquid-filled units, making it a truly safe choice for placing power directly near sensitive server racks, PDUs, and UPS systems. The transformer is built for continuous, uninterrupted operation, featuring a robust design that minimizes noise, withstands network harmonics, and requires virtually no maintenance over its long service life. Key Features
Technical Specifications
Server Room & UPS Power Distribution Solution Addressing Critical Power Needs Through Focused Design Server rooms and data centers present specific operating conditions that demand specialized electrical design. The high concentration of sensitive microprocessors, UPS battery banks, and precision cooling creates a need for a stable, clean, and never-failing power source. This transformer incorporates several technical measures to guarantee performance under these conditions.
Frequently Asked Questions Q1: Can this 250kVA dry type distribution transformer be safely
placed inside our server room? A: Yes, it is specifically rated for indoor installation. The epoxy-resin insulation is fire-resistant and self-extinguishing, producing no toxic smoke. Without oil, there is no containment pit needed. It can occupy dedicated electrical rooms or secure corners of server halls with minimal clearance, providing power right where it is consumed. Q2: Is this transformer compatible with our online UPS systems that
generate harmonics? A: Absolutely. It features a Dyn11 vector group and foil-type secondary winding, which is a proven design for withstanding the neutral currents and harmonic heating associated with UPS equipment. This design prevents thermal aging and allows the transformer to operate reliably within your total cost of ownership expectations. Q3: How does the dry type technology protect our critical server
load from electrical failure? A: The high-voltage coils are cast under vacuum in a solid resin compound. This eliminates air voids that can lead to partial discharge over time. Additionally, the transformer inherently limits fault currents and is highly resilient to short circuits, ensuring that one component short does not translate into a catastrophic fire or complete bus failure affecting your entire critical infrastructure. Q4: What maintenance schedule does this transformer require? A: The scheduled maintenance is minimal. There are no oil samples, gasket replacements, or pumps. We recommend an annual visual inspection to check terminal connections and a periodic dust cleaning if the unit is not inside an IP54 enclosure. The sealed coil surface can simply be wiped down. Q5: What can we expect regarding noise levels and cooling in an
office-adjacent Data Center? A: The noise is remarkably low, achieved through a precision-stepped lap core and high-quality silicon steel. Under natural air cooling, it operates quietly and without any fan noise. If you opt for the AF package for enhanced overload, the fan control is temperature-activated and runs only when required, preserving the acoustic environment. Q6: Can you customize the enclosure and connection layout for our
electrical switchgear line-up? A: Yes. As a custom transformer manufacturer, we configure enclosure ingress protection, cable entry (top/bottom), and busbar orientation to ensure a seamless interface with your switchgear and busway system. We work directly with EPC projects to meet precise site specifications. Specify your power infrastructure today — Contact us for a custom 250kVA dry type transformer quotation. |
||||||||||||||||||||||||||||
| Product Tags: 11kV dry type transformer server room power distribution transformer maintenance free distribution transformer |
|
Durable and Precise Voltage Regulation 30KVA 50KVA-2500KVA Three phase 0.4KV to 11KV Auto Transformer for Industrial and Civil Equipment Pressure Regulation OEM |
|
Wide Voltage Range Adaptability 315-2500KVA Three phase 11KV to 0.4kv Auto Transformer for Industrial Equipment Pressure Regulation Manufacturer |
|
30 kVA High Efficiency Three Phase Dry Type Autotransformer for Industrial Voltage Adaptation |
|
Easy Installation and Maintenance 200KVA Three-Phase Auto Transformer 11kV 0.4KV for Civil and Commercial Electricity Consumption Manufacturer |
|
Durable and Corrosion-resistant Three-Phase 160KVA Auto Transformer 11kV to 0.4KV for Transmission and Distribution Systems Manufacturer |
|
Precise Voltage Regulation 11KV to 0.4KV Auto Transformer 250KVA for Industrial Equipment Pressure Regulation Direct Supply |