Schneider Electric LSS100300 SpaceLogic KNX BMS IP Gateway Original New

Detailed Product Description
Product Overview

The Schneider Electric LSS100300 is a dedicated BACnet/IP Gateway designed specifically for integrating KNX building automation systems with Building Management Systems (BMS). Unlike the LSS100100 and LSS100200 logic controllers, the LSS100300 serves as a protocol converter, enabling bidirectional communication between KNX installations and BACnet-based BMS platforms like EcoStruxure Building Operation.


Technical Specifications
General Information
ParameterSpecification
Product NameSpaceLogic KNX BMS IP Gateway
Product CodeLSS100300
Product TypeProtocol Gateway / Router
FunctionKNX to BACnet/IP protocol conversion
Protection RatingIP20
MountingDIN rail
OriginLatvia (LV)
RoHS CompliantYes
Electrical Parameters
ParameterSpecification
Supply Voltage24 V DC
Power Consumption2 W (standby) / 12 W (max)
Status IndicatorsCPU load (green LED), KNX power/reset (green/red LED)
Communication Interfaces
InterfaceSpecification
KNXKNX TP (Twisted Pair) - bus terminal
Ethernet1* RJ45 (BACnet/IP)
ProtocolsKNX TP, BACnet/IP
Physical Specifications
ParameterSpecification
MountingDIN rail mount
InstallationStandard electrical panel
Environmental Conditions
ParameterSpecification
Operating TemperatureStandard industrial range
HumidityNon-condensing

Key Features
Bidirectional Protocol Gateway
  • KNX to BACnet/IP conversion: Seamlessly integrates KNX devices into BACnet-based BMS
  • Bidirectional communication: Read and write operations between both protocols
  • Multi-device support: Connects entire KNX installations to BMS platforms
BMS Integration
  • EcoStruxure Building Operation: Native compatibility with Schneider Electric BMS
  • Third-party BMS support: Works with any BACnet/IP-compliant building management system
  • Simplified commissioning: Reduces integration complexity for mixed-protocol environments
Core Functions
  • Protocol translation: Automatic conversion of KNX data points to BACnet objects
  • Data mapping: Flexible configuration of KNX group addresses to BACnet properties
  • Real-time monitoring: Live status updates between KNX field devices and BMS
  • Control operations: BMS can send commands to KNX actuators through the gateway
Network Services
  • KNX IP routing: Functions as KNXnet/IP router
  • BACnet B-BC profile: BACnet Building Controller certification
  • Ethernet connectivity: Standard RJ45 connection to IP networks

LSS100300 vs LSS100100/LSS100200 Comparison
FeatureLSS100100 (Wiser for KNX)LSS100200 (spaceLYnk)LSS100300 (BMS Gateway)
Primary FunctionLogic ControllerLogic ControllerProtocol Gateway
Target UseResidential / Small commercialCommercial buildingsBMS Integration
BACnet RoleServer (150 points)Server (2,000 points)Gateway/Translator
Web SCADAYesYesNo (BMS handles visualization)
Logic ProgrammingYesYesNo (pass-through device)
Modbus SupportYesYes (31 devices)Via BMS
KNX InterfaceTP-UART2TP1TP (dedicated)
Best ForStandalone controlLarge building controlKNX-BMS integration

Typical Applications
Commercial Building Integration
  • Office building KNX lighting integration with central BMS
  • HVAC system coordination between KNX sensors and BACnet controllers
  • Energy management system (EMS) integration
Hospitality BMS Projects
  • Hotel room KNX controls connected to property management systems
  • Centralized monitoring of guest room status
  • Integration with building-wide energy optimization
Healthcare Facilities
  • KNX lighting and blinds integration with hospital BMS
  • Nurse call system integration
  • Compliance monitoring and reporting
Educational Campuses
  • Multi-building KNX integration into campus-wide BMS
  • Centralized scheduling and control
  • Energy dashboard integration
Retrofit Projects
  • Adding KNX zones to existing BACnet-based buildings
  • Phased upgrades without replacing entire BMS
  • Mixed protocol environments

Why Choose LSS100300?
AdvantageBenefit
Dedicated GatewayOptimized for protocol conversion, not general control
BMS NativeDesigned specifically for EcoStruxure and BACnet BMS
Simplified ArchitectureNo programming required, configuration only
Reliable BridgingPurpose-built for 24/7 KNX-BMS communication
Cost EffectiveLower cost than full logic controller for gateway-only needs
ScalableOne gateway handles entire KNX installation

System Architecture Example
┌─────────────────┐ ┌─────────────┐ ┌─────────────────┐ │ KNX Devices │◄───────►│ LSS100300 │◄───────►│ BMS Platform │ │ (Sensors, │ KNX TP │ Gateway │Ethernet │ (EcoStruxure/ │ │ Actuators) │ │ │ BACnet/IP Third-party) │ └─────────────────┘ └─────────────┘ └─────────────────┘

Ordering Information
ItemDetails
Product CodeLSS100300
EAN/GTIN3606482215856
Minimum Order1 piece
Package ContentsGateway device with installation manual

Note: Check regional availability with your Schneider Electric distributor.


Related Products
  • LSS100100 (Wiser for KNX) - Logic controller for residential
  • LSS100200 (spaceLYnk) - Logic controller for commercial
  • EcoStruxure Building Operation - BMS platform
  • KNX Power Supplies - For KNX bus powering
  • KNX Sensors & Actuators - Field devices

When to Use LSS100300 vs Logic Controllers

Choose LSS100300 when:

  • You have an existing or planned BACnet BMS
  • You need to integrate KNX devices into a central management platform
  • You don't need local logic programming
  • The BMS will handle visualization and control logic

Choose LSS100100/LSS100200 when:

  • You need standalone control without a BMS
  • You want built-in Web SCADA visualization
  • You need local logic programming and scheduling
  • You're building a smaller system without central BMS