China IEC Test Equipment manufacturer
Guangzhou HongCe Equipment Co., Ltd.
We provide you with industry leading test equipment, advanced online system and solutions–anywhere in the world.
13
Home > Products > Impact Testing Machine >

Spring Impact Hammer Calibration Device for Impact Energy Verification | IEC 60068-2-75 Impact Testing Machine Calibration System

Spring Impact Hammer Calibration Device for Impact Energy Verification | IEC 60068-2-75 Impact Testing Machine Calibration System

Minimum Order Quantity 1 set
Delivery Time 20 working days
Measurement range 0~2J
Payment Terms T/T
Standard IEC 60068-2-75 annex B
Repeat accuracy ±0.01J
Model Number SH-7
Calibration Device for Spring Impact Hammer <0.002J
Brand Name HongCe
Balance weight 2J Copper weight 1 piece
Packaging Details plywood
Price Negotiatable
Test calibration
Supply Ability 20 set per month
Test object Calibration Device
Accuracy 0.01J
Certification Third part calibration certificate(cost additional)
Place of Origin China
Detailed Product Description

Spring Impact Hammer Calibration Device for Impact Energy Verification | IEC 60068-2-75 Impact Testing Machine Calibration System

Product Overview

The Spring Impact Hammer Calibration Device is a precision verification system designed for measuring and validating the impact energy generated by spring-operated impact hammers. It is widely used by testing laboratories, certification bodies, quality inspection agencies, electrical appliance manufacturers, and research institutions to ensure that impact hammers comply with international safety testing requirements.

Why Accurate Impact Hammer Calibration Matters

A spring impact hammer is one of the most commonly used tools in electrical product safety testing. Over time, repeated usage may cause mechanical wear, resulting in deviations in impact energy.

Without periodic calibration:

  • Test results may become unreliable
  • Product certifications may be challenged
  • Laboratory accreditation requirements may not be met
  • Product quality risks may increase

The HongCe Spring Impact Hammer Calibration Device helps laboratories maintain confidence in every impact test performed.

Features

High Accuracy Energy Verification

Designed specifically for verifying impact energy generated by spring-operated impact hammers.

IEC-Compliant Design

Manufactured according to IEC 60068-2-75 Annex B calibration requirements.

Precision Mechanical Structure

Provides stable and repeatable measurement results.

Durable Construction

High-quality mechanical components ensure long-term operational stability.

Easy Operation

User-friendly structure minimizes operator training requirements.

International Reference Standards

IEC 60068-2-75

Environmental Testing – Test Eh: Hammer Tests

Annex B – Calibration of Spring Hammers

The standard specifies:

  • Calibration methods for spring impact hammers
  • Impact energy measurement requirements
  • Verification procedures
  • Accuracy requirements
  • Mechanical calibration principles
Specifications:
Test objectSpring operated impact hammer
Reference standard

IEC 60068-2-75 Annex B;

IEC 60068-2-63 Annex A

TestAccuracy calibration
Accuracy0.01J
Repeat accuracy±0.01J
Measurement range0~2J
Guide groove diameter51mm
The energy loss of the pendulum<0.002J
Trigger distance>30mm
Balance weight2J Copper weight 1 piece
MaterialStainless steel
Product Functions
  • Verify impact hammer energy output
  • Measure impact energy consistency
  • Validate spring hammer performance
  • Support laboratory equipment calibration programs
  • Assist certification testing processes
  • Ensure compliance with IEC safety standards
  • Reduce testing uncertainty
  • Improve repeatability of impact testing
Feature:
  • Accuracy: 0.01J
  • Repeat accuracy: ±0.01J
  • Measurement range: 0~2J
  • Guide groove diameter: 51mm
  • The energy loss of the pendulum: <0.002J
  • Trigger distance: >30mm
  • Balance weight: 2J Copper weight 1 piece
  • Material: stainless steel,
  • Advantages: statble and reliable, easy operation, nice appearance
Detailed images

FAQ

Q1: What is the purpose of the SH-7 Calibration Device?

It is used to verify the impact energy generated by spring impact hammers according to IEC 60068-2-75 requirements.

Q2: Which standards require spring hammer calibration?

IEC 60068-2-75 Annex B specifies calibration requirements for spring impact hammers.

Q3: Who typically uses this equipment?

Testing laboratories, certification organizations, quality control departments, manufacturers, and research institutes.

Q4: Can HongCe provide calibration support?

Yes. HongCe provides technical guidance and application support.

Q5: Is OEM or customization available?

Yes. Customized solutions are available according to customer requirements.

About HongCe

HongCe is a professional manufacturer specializing in IEC testing equipment, environmental testing systems, waterproof testing equipment, impact testing machines, appliance testing instruments, and laboratory solutions.

Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Guangzhou HongCe Equipment Co., Ltd.
Subject:
Message: