Cold Bending Test Machine HDX1307
Technical parameters: Station:2 Diameter of samples:Φ2.5mm ~12.5mm The number of turns:2 to 10 turns, and the number of turns shall be as specified in the following table:
Test condition: The diameter of the mandrel shall be between 4 and 5 times the diameter of the test piece. Standard equip with the mandrel :Ф4, Ф5, Ф6, Ф7, Ф8, Ф10, Ф12, Ф14, Ф16, Ф18, Ф20, Ф24, Ф37.5mm Rotation speed: 5S/ turn, manual control Diameter of pipe: Ф3.5, Ф6, Ф10, Ф12, Ф16mm, each of two pieces
Description: This device is intended in general for cables with an overall diameter up to and including 12.5 mm, or for flat cables, a major axis dimension up to and including 20 mm. According to the standard IEC60811-1-4 clause 8.1 and 8.2, common test methods for insulating and sheathing materials of electric and optical cables-part 1-4:Methods for general application-Test at low temperature.
Test sample: Cables with an overall diameter up to and including 12.5 mm, or for flat cables, a major axis dimension up to and including 20 mm.
Feature: Made of stainless steel, 2 stations, equip with the extended handle which can be connected to the outside of the low temperature chamber. |
||||||||||||
Product Tags: power cable tester electric wire tester |
![]() |
AC220V±5% 60Hz Output Voltage 0~280V 6-station Cable Testing Equipment |
![]() |
76mm Diameter Of Gyration Electrical Cable Testing Equipment UL486A B International Reference Standards For Performance |
![]() |
Power Cord Bending Machine Load System 6-Station Cable Testing Equipment 0-40A Adjustable Current Ammeter Accuracy ±1% |
![]() |
Power Cord Bending Machine Power Load Box 0-40A Intelligent Load Test Six-station Cable Fatigue Detection Equipment |
![]() |
Universal 1000mm Conductor Resistance Cable Testing Equipment |
![]() |
IEC60245 Cable Tester With Universal Conductor Resistance, Providing Reliable Testing. |