China Copper Nickel Alloy Wire manufacturer
Shanghai Tankii Alloy Material Co.,Ltd
Shanghai Tankii Alloy Material Co.,Ltd First Quality, Sincere Service
11
Home > Products > Thermocouple Bare Wire >

KX Stranded Thermocouple Bare Wire IEC Class I Bright For Thermocouple Cable

Browse Categories

Shanghai Tankii Alloy Material Co.,Ltd

City: shanghai

Province/State:shanghai

Country/Region:china

Tel:86-21-56110178

Contact Person:
Mr.Martin Lee
View Contact Details

KX Stranded Thermocouple Bare Wire IEC Class I Bright For Thermocouple Cable

Brand Name Tankii
Model Number KX
Certification ISO9001
Place of Origin China Mainland
Minimum Order Quantity 10kg per leg
Price Negotiation
Payment Terms T/T, Paypal, Western Union, MoneyGram,
Supply Ability 1000Ton per year
Delivery Time 5-7 days after getting the payment
Packaging Details Standard exoprt package in carton box or wooden box
Material NiCr -NiSi
Surface Bright
Diameter 7*0.15mm
Wire Type stranded wire
Insulation no
Wire class IEC class I
Leading time 5~10 days after getting the payment
Application thermocouple,temperature measurement
Standard ANSI,IEC584
Detailed Product Description

 
KX Stranded Thermocouple Extension Wire With IEC60584 Class 2 Used For Thermocouple Cable
 
Shanghai tankii, specializing in producing thermocouple wire, thermocouple cable, thermocouple MI cable.
A typical thermocouple construction consists of a pair of dissimilar metals that are electrically joined together at the sensing point and connected to a voltage measuring instrument at the other end. When one junction is hotter than the other, a thermal “electromotive” force (in millivolts) is produced that is roughly proportional to the difference in temperature between the hot and cold junctions.

 

Tankii Type K thermocouple is composed of a Nickel-10% chromium (+) wire versus a nickel-5% aluminum and silicon (-) wire. This type of thermocouple should only be used in oxidizing or inert atmospheres with a service temperature range between -200°C and 1260°C (-330°F to 2300°F). They are most widely used at temperatures above 540'C (1000"F) due to superior oxidation resistance in comparison to Types E, T, or J. There are some conditions which should be avoided when using Type K thermocouples. Vacuum applications should not use Type K due to vaporization of chromium in the positive element. Tankii Type K thermocouples should not be used in Sulfurous environments since both elements will rapidly corrode and the negative element will eventually fail mechanically due to becoming brittle. Reducing atmospheres should also be avoided. Low oxygen levels can cause the Green-Rot phenomenon in which the chromium in the elements starts to oxidize causing large negative drifts in calibration.

 

KX Stranded Thermocouple Extension Wire With IEC60584 Class 2 Used For Thermocouple Cable
 
Characteristics:
The thermocouple wires have excellent performance and are extensively used in the temperature measurement and control in different fields, such as metallurgy, chemical industry, petroleum industry, machinery-electric industry, energy industry, agriculture and military industry.
 
Tankii products conform to the standards of IEC584 -1and IEC-2.

 
Tankii Thermocouple strips, thermocouple connectors are available.
Tankii KX, JX, TX KC, RC,EX wire with class 1 and 2 are available.
 
Application Range of Tankii  thermocouple wire:
 
1. Aerospace and Composites
2. Aluminum industry
3. Food and Pharmaceutical
4. Forgings
5. Glass, Ceramics, Clay Tiles, Bricks
6. Heat Treating
7. Petroleum, Downhole Oil & Gas
8. Sensor Manufacturing
9. Steel industry
10. Utilities Power Generation
 
KX Stranded Thermocouple Extension Wire With IEC60584 Class 2 Used For Thermocouple Cable
 
Tankii Thermocouple Type and Temperature Range

Thermocouple type and index
 

Measurement Range

Type
 

Index
 

 
PtRh30-PtRh6

B600~1700

 
PtRh13-Pt

R0~1600

 
PtRh10-Pt

S0~1600

 
NiCr-NiSi

K-200~1300

 
NiCr-CuNi (constantan)

E-200~900

 
Fe-CuNi (constantan)

J-40~750

 
Cu-CuNi (constantan)

T-200~350

 
NiCrSi-NiSi

N-200~1300
 

The allowable grade and Tolerance are obtained at 0℃

Thermocouple
Type

Grade

Temperature range

Allowable Tolerance /℃
Type B600~1700±0.25% t
600~800±4
800~1700±0.5%t
Type R(S)0~1100±1
1100~1600±[1+(t-1100) ×0.3%]
0~600±1.5
600~1600±0.25% t
Type K and Type N-40~1100±1.5℃ or ±0.4%t
-40~1300±2.5℃ or ±0.75%t
-200~40±2.5℃ or ±1.5%t
Type E-40~1100±1.5℃ or ±0.4%t
-40~1300±2.5℃ or ±0.75%t
-200~40±2.5℃ or ±1.5%t
Type J-40~750±1.5℃ or ±0.4%t
-40~750±2.5℃ or ±0.75%t
Type T-40~350±0.5℃ or ±0.4%t
-40~350±1.0℃ or ±0.75%t
-200~40±1.0℃ or ±1.5%t

 
 
 

 Delivery and Packing of thermocouple wire:
 
1. Packaging Details : DIN spools with plastic film wrapped and carton package. 
 
2. Leading time : 5 - 20 days, as the order quantity of thermocouple wire.
 
3. Delivery: By express, air, sea as per thermocouple wire qty
 
 
KX Stranded Thermocouple Extension Wire With IEC60584 Class 2 Used For Thermocouple Cable
 
 
 
Welcome to call me or email to me for more information on K type thermocouple wire, Thermocouple stranded wire , thermocouple  flat wire, thermocouple strip.

































Product Tags: thermocouple lead wire   high temperature thermocouple wire  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Shanghai Tankii Alloy Material Co.,Ltd
Subject:
Message:
Characters Remaining: (80/3000)