Brand Name SSCH
Model Number GY-PDT-1
Certification CE
Place of Origin CHINA SHENZHEN
Minimum Order Quantity 1
Price usd 1650-1980usd
Payment Terms T/T, Western Union paypal
Supply Ability 500 pcs mouths
Delivery Time 2-3working day after payment confirm
Packaging Details 1pcs/box 1kg/box
Model NO. GY-PDT1
Item Name Brain Photobiomodulation Helmet
Frequency 1Hz-20000Hz
Option Timing 0-30 Minutes
LED Quantity 256
Wavelength 810nm
Treatment1 Stroke, Brain Injuiry
Treatment2 Alzheimer, Parkinson
Treatment 3 Mental Disorder, Depression
Specification 28cm*22cm*11cm
Detailed Product Description

 

PDT treatment anti depression brain neuro stimulator depression therapy device

 

Brain Photobiomodulation Machine:


The Brain Photobiomodulation Machine is a therapeutic instrument based on the principle of photobiomodulation. It has a good therapeutic effect on traumatic events (stroke, traumatic brain injury, and global ischemia), degenerative diseases (dementia, Alzheimer's and Parkinson's), and psychiatric disorders (depression, anxiety, post traumatic stress disorder).

 

What is Photobiomodulation?


Photobiomodulation(PBM) therapy is defined as the utilization of non-ionizing electromagnetic energy to trigger photochemical changes within cellular structures that are receptive to photons. Mitochondria is particularly receptive to this process. At the cellular level, visible red and near infrared light (NIR) energy are absorbed by mitochondria, which perform the function of producing cellular energy called "ATP". The key to this entire process is a mitochondrial enzyme called cytochrome oxidase c, a chromophore, which accepts photonic energy of specific wavelengths when functioning below par.

Principle:


Cytochrome C oxidase (CCO, also known as complex IV) is a specific structure in mitochondria that ACTS as a photon receptor and thus plays the PBM effect.PBM prevents respiratory inhibition (and correspondingly reduces energy storage) in stress cells by isolating nitric oxide (NO) and reversing the shift of oxygen in cytochrome C oxidase.This triggers transcription factors that alter gene expression levels.The binding of nitric oxide (NO) to copper (or heme) centers in the mitochondrial cytochrome C oxidase (CCO) inhibits cell respiration.But cytochrome C oxidase, which absorbs red or near-infrared (NIR) light, dissociates nitric oxide, restoring oxygen, increasing cellular respiration, and forming adenosine triphosphate (ATP).This triggers a cascade of intracellular reactions involving nitric oxide, reactive oxygen species (ROS), and cyclic adenosine phosphate (cAMP) that produce beneficial effects of PBM.

 

 

Specifications

 

NameBrain Photobiomodulation Machine
ModelGY-PDT1
LED Wavelength810 nm
Led Quantity256
Power(total helmet)15 W
Power(one LED)60 mW
Power24 mW/cm2
CertificateCE FDA
OEMSupport
ColorWhite/Black
MOQ1pcs

 

Main Function:
•  NIR light can penetrate the head and reach the brain.
•  NIR is absorbed by cytochrome c oxidase in mitochondria.
•  Heat-gated ion channels also play a role.
•  Increased blood flow, energy, neuroprotection, less inflammation, brain repair.
•  Can treat traumatic (stroke, TBI), neurodegenerative and psychiatric diseases.


Indications:
1.  Traumatic events (stroke, traumatic brain injury, and global ischemia).
2.  Degenerative diseases (dementia, Alzheimer's and Parkinson's).
3.  Psychiatric disorders (depression, anxiety, post traumatic stress disorder).



Feature:


6-30 minutes time ajustable
1-20000Hz frequency adjustable

 


Different frequency for different brain diseases:


Cerebral arteriosclerosis Insufficient, blood supply to the brain :30 minutes 50 Hz
Brain atrophy : 30 minutes 40-50 Hz
Alzheimer's disease (AD) :30 minutes 50 Hz
Children with autism :30 minutes 10-30 Hz
Cerebral thrombosis, Cerebral infarction :30 minutes 50 Hz


Lacunar infarction: 30 minutes 50 Hz
Recovery of traumatic brain injury after operation: 30 minutes 30 Hz
The recovery period after cerebral poisoning: 30 minutes 30-50 Hz
Children with cerebral palsy :20-30 minutes 5-15 Hz
Parkinson's disease :30 minutes 30-50 Hz
Depression : 20-30 minutes 50 Hz


Mental disorders: 20-30 minutes 30-50 Hz
Insomnia: 20-30 minutes 5-15 Hz
Nervous headache :20-30 minutes 20-40 Hz
High blood pressure: 20-30 minutes 5-15 Hz
Brain fatigue disease: 20-30 minutes 30 Hz
Memory loss :20-30 minutes 30 Hz


Neurasthenia :20-30 minutes 5-20 Hz
Schizophrenia: 20-30 minutes 5-20 Hz

 

 

Suggest Different Frequencies for Different kinds of Diseases

 

DiseaseTreatment TimeTreatment Frequency
Cerebral arteriosclerosis Insufficient, blood supply to the brain30 minutes50 Hz
Brain atrophy30 minutes40-50 Hz
Alzheimer's disease (AD)30 minutes50 Hz
Children with autism30 minutes10-30 Hz
Cerebral thrombosis, Cerebral infarction30 minutes50 Hz
Lacunar infarction30 minutes50 Hz
Recovery of traumatic brain injury after operation30 minutes30 Hz
The recovery period after cerebral poisoning30 minutes30-50 Hz
Children with cerebral palsy20-30 minutes5-15 Hz
Parkinson's disease30 minutes30-50 Hz
Depression20-30 minutes50 Hz
Mental disorders20-30 minutes30-50 Hz
Insomnia20-30 minutes5-15 Hz
Nervous headache20-30 minutes20-40 Hz
High blood pressure20-30 minutes5-15 Hz
Brain fatigue disease20-30 minutes30 Hz
Memory loss20-30 minutes30 Hz
Neurasthenia20-30 minutes5-20 Hz
Schizophrenia20-30 minutes5-20 Hz

 

 

How often does a person use the helmet?

 

For long-term chronic diseases, such as degenerative diseases, the recommended course of treatment is 3-6 months.

For short-term symptoms, such as concussion, migraine, depression, etc., the recommended course of treatment is 1-3 months.

 

According to the severity of the patient's symptoms, use 4-6 times a week, 1-2 times a day. At the beginning of the treatment, it is recommended to give the patient a process of adaptation. About the power intensity and time, you can start from 25% , 12 minutes. Gradually increase the power intensity and time step by step. After a adapation period, can use 75-100% intensity for 24-30 minutes.


Q&A:

 

1. How long to set the timer?

You can choose 6 minutes - 12 minutes - 18 minutes - 24 minutes - 30 minutes

 

2. Are your infrared LEDs near infrared?

Our model is near infrared with 810nm.

 

3. Why do you use a mix of red LED and infrared LED? Why are they red?

We use 256pcs near infrared light for therapy. There are 4 pcs red led for instruction, to show you the device is working. Sometimes the near infrared is hardly to be seen from eyes, so the red light just for instruction, not for therapy function.

 

4. Have you found that your machine is able to actually penetrate the brain?

Yes, we have got a lot of research to prove this thoery which 810nm light can penetrate the brian.


5. How deep have you seen your machines tested to penetrate through the brain?

The 810nm light can penetrate our skull and works on nerve cell, and there is Cytochrome C Oxidase inside the Mitochondria of the cell, to promote the cell viability.


6. What frequency?

For the button model, the frequency is 40Hz, for the touch screen model, the frequency is 1-20,000 Hz adjustable.

 

 

Customer feedback:

 

Product Tags: PDT Treatment Depression Therapy Device   Neuro Stimulator Depression Therapy Device   810nm Depression Therapy Device  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Shenzhen Guangyang Zhongkang Technology Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)