China Lab Test Machines manufacturer
Guangdong Haida Equipment Co., Ltd.
Haida International Equipment CO.,LTD
12
Home > Products > Chair Test Equipment >

5124-HD Wheelchair High And Low Temperature Environmental Test Chamber

5124-HD Wheelchair High And Low Temperature Environmental Test Chamber

Brand Name Haida
Model Number 5124-HD
Certification CE、ISO
Place of Origin China
Minimum Order Quantity 1 set
Price Negotiation
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 300 Sets per Month
Delivery Time 20 days after order confirmed
Packaging Details each set protected with resin fiber and PP film, then put into Strong wooden case with operation man
Material Steel
Optional Features Customizable load capacity and dimensions
Keyword Furniture Testing Machine
Power Electronic
Testing Method Dynamic and static load testing
Power Supply AC/DC
Use Chair
Type Test Equipment
Unit Switch gf,kgf, N, LBf, W, KN, T
Driving Mode variable frequency motor and timing belt
Power Source Electricity
Lcd Display Yes
Adjustable Armrests Yes
Detailed Product Description
5124-HD Wheelchair high and low temperature environmental test chamber
EQUIPMENT DETAILS
1. Structure
1.1 Cooling System
  1. The refrigerating system equips Germany Bock, and uses environmentally friendly refrigerant (R404a). Adopting binary low temperature circuit system design, it is convenient to use different compressors for work in different temperature regions.
  2. Temperature and humidity control using P.I.D + S.S.R system coordinated control with the same channel. It has the function of automatic calculation, which can immediately modify the temperature and humidity change conditions to make the temperature and humidity control more accurate and stable.
  3. High-precision controllers of temperature and humidity. The relative temperature and humidity performance is accurately set and displayed with a resolution of 0.1 ℃.
1.2 Temperature and Humidification System
  1. Temperature system using Nickel-chromium alloy high-speed heating electric wire;
  2. High temperature system is completely independent;
  3. The humidity system using stainless steel tube built-in nickel-chromium alloy high-speed heating electric wire and high-temperature magnesium oxide powder, which has fast response and long life;
  4. The temperature and humidification system is completely independent, and humidity has automatic water supplement device.
1.3 Control System
Temp. & Humid. SensorHigh precision PT100 Platinum resistance
ControllerWeintek
Display Function
  • Temp. & humid. Setting (SV) Practical (PV) value can be displayed directly
  • Display numbers, paragraphs, remaining time and cycles, running time
  • Program editing and graphic curve display,
  • Fixed or program operation status display,
Interface
  • RS-232 or R485 port design
  • Connected to computer
  • Monitor and remote control by computer and Ethernet optional
1.4 Protection System
  1. Protection for Electrical leakage
  2. Over-temperature
  3. Compressor overvoltage and overload
  4. Heater short circuit
  5. Water shortage
2. Main Technical Parameters
2.1 Capacity and Material
Internal dimension(W*D*H)1200*2500*1500mm
External dimension(W*D*H)2500*3000*2500mm
Internal material1.2mm thickness SUS#304 stainless steel, mirror finished;
External material1.2mm thickness cold-rolled steel plate baking
2.2 Temperature
Temperature range-40℃ ~ + 100℃
Temperature fluctuation±0.5℃
Temperature uniformity≤2℃
Temperature rate1℃/min in average (without loading)
3℃/min in average (without loading)
2.4 Power Supply
Power sourceThree-phase, 380V,50Hz
Power3 kw
Current18 A
WeightApprox. 360kg
2.5 Cooling System and Others
CompressorSemi-Hermertically Sealed Germany Bock compressor
RefrigerantR449A
Cooling methodSingle-stage compression
Cooling methodAir-cooled flake condenser, cooling fan for heat dissipation
Heating systemNichrome stainless steel heater
Sample traySUS#304 stainless steel 2 pieces
Testing holeDiameter 50mm*2, Located left and right side, for sample connecting
EvaporatorFinned tube heat exchanger
Dry filterAbsorb the residual moisture and acidic substances in the refrigerant of the refrigeration system, and filter out solid particles, copper shavings, etc. in the system to protect the normal operation of the expansion valve and capillary tube, and prevent ice blocking and dirty blocking.
Door handleNon-reaction, explosion-proof door handle, easy to operate, safe and reliable
Insulation100mm polyurethane rigid foam and 100mm high density glass fiber cotton