Humidity testing Powerful Air Circulator Smooth Airflow Temperature
Chamber
Temperature and humidity chamber.pdf
1. Performance
Humidity testing Powerful air circulator smooth airflow Temperature
Chamber can simulate both temperature and humidity. Controlled humidity
from 10% RH to 95% RH can be maintained within the dry-bulb
temperature range of +10°C to +85°C, limited by a 6°C dew point.
For lower dew point conditions (low RH or relative humidity at low
dry-bulb temperatures), you will need dry air purge or GN2 (gaseous
nitrogen) purge. See the humidity range chart on the specification
page of each temperature-humidity chamber for humidity range
limits.
Questions for Performance Evolution Request:
System & Performance Options
- Low and Ultra-Low Humidity Extends the humidity control range.
(Normal Humidity Range Diagramed)
- Water-cooling system.
- Dry Air Purge keeps moisture in the chamber extremely low by
purging with -40 °C. Compressed air supply required
- Additional shelves, 50 Kg loading
- Cable ports with flexible silicone plug, 50 , 100, 150mm or
customer specific diameters
2. Specifications of Stability High Low Temperature and
Humidity Test Machine:
Range – 70 to 150°C
Temp/Humidity | HD-E702-100-7 | HD-E702-150-7 | HD-E702-225-7 |
| HD-E702-408-7 | HD-E702-800-7 | HD-E702-1000-7 |
Temp-only | HD-E702-100T-7 | HD-E702-150T-7 | HD-E702-225T-7 |
| HD-E702-408T-7 | HD-E702-800T-7 | HD-E702-1000T-7 |
Temperature Range: | -70°C ~150°C |
Cooling Capacity | ~ 2.5 kW at -50°C | ~ 3 kW at -50°C | ~ 5 kW at -50°C |
| | ~ 6.5 kW at-50°C | ~ 8.5 kW at -50°C | ~ 9 kW at - -50°C |
Heating System | ~ 5 kW | ~ 5 kW | ~ 5.5 kW |
| | ~6.5 kW | ~ 8.5 kW | ~ 9 kW |
Temperature Fluctuation: | ±0.5°C |
Temperature Gradient: | ±0.5°C~±0.2°C |
Heating Rate†: | ≥3℃ / min average ( Advance model 5 – 15 ℃ / min) |
Cooling Rate†: | ≥1℃ / min average (Advance model 5 - 15℃ / min) |
Humidity Range: | 10%~95%RH (Ref to Normal Humidity Range Diagramed) |
Humidity Fluctuation: | ±1.5%RH~±2.0%RH |
Humidity Gradient: | ±3%RH |
Dimensions |
Workspace dimensions (WxDxH)mm: | 500x400x500 HD-E702-100 | 600x500x500 HD-E702-150 | 750x500x600 HD-E702-225 |
| 850x650x800 HD-E702-800 | 1000x1000x800 HD-E702-800 | 1000x1000x1000 HD-E702-1000 |
Exterior dimensions (WxDxH)mm: | 1400x850x1050 | 1500x950x1050 | 1650x950x1150 |
| 1750x1050x1350 | 1900x1450x1350 | 1900x1450x1550 |
Site Requirements |
Electrical Supply: | 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) |
Humidity Water | Distilled water |
Condensate Drain: | 1/2" hose connection (gravity drain) |
Range – 40 to 150°C
Temp/Humidity | HD-E702-100-4 | HD-E702-150-4 | HD-E702-225-4 |
| HD-E702-408-4 | HD-E702-800-4 | HD-E702-1000-4 |
Temp-only | HD-E702-100T-4 | HD-E702-150T-4 | HD-E702-225T-4 |
| HD-E702-408T-4 | HD-E702-800T-4 | HD-E702-1000T-4 |
Temperature Range: | -40°C ~150°C |
Cooling Capacity | ~ 2 kW at -20°C | ~ 2.5 kW at -20°C | ~ 4.5 kW at -20°C |
| | ~ 5.5 kW at-20°C | ~ 8 kW at -20°C | ~ 8.5 kW at - -20°C |
Heating System | ~ 5 kW | ~ 5 kW | ~ 5.5 kW |
| | ~6.5 kW | ~ 8.5 kW | ~ 9 kW |
Temperature Fluctuation: | ±0.5°C |
Temperature Gradient: | ±0.5°C~±0.2°C |
Heating Rate†: | ≥3℃ / min average ( Advance model 5 – 15 ℃ / min) |
Cooling Rate†: | ≥1℃ / min average (Advance model 5 - 15℃ / min) |
Humidity Range: | 10%~95%RH (Ref to Normal Humidity Range Diagramed) |
Humidity Fluctuation: | ±1.5%RH~±2.0%RH |
Humidity Gradient: | ±3%RH |
Dimensions |
Workspace dimensions (WxDxH)mm: | 500x400x500 HD-E702-100 | 600x500x500 HD-E702-150 | 750x500x600 HD-E702-225 |
| 850x650x800 HD-E702-800 | 1000x1000x800 HD-E702-800 | 1000x1000x1000 HD-E702-1000 |
Exterior dimensions (WxDxH)mm: | 1400x850x1050 | 1500x950x1050 | 1650x950x1150 |
| 1750x1050x1350 | 1900x1450x1350 | 1900x1450x1550 |
Site Requirements |
Electrical Supply: | 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) |
Humidity Water | Distilled Water |
Condensate Drain: | 1/2" hose connection (gravity drain) |
3. Features:
Stainless steel exterior
Full thermal break around doorframe
One 50mm (2") diameter cable port on left, with flexible silicone
plug
Three levels of overheat protection
115V main power for BTL-433 model
High performance and quiet operation (65 dBa)
Easy lift-off service panels, electrical access on left
WATLOW F4T PROGRAMMER/CONTROLLER
Popular PID controller with touch-screen operation
Stores 40 different profiles
Step types include: ramp, soak, jump/repeat, auto-start, and end
Ethernet interface for remote monitoring and operation
Standard Features:
- Stainless# 304 steel for interior
- Paint steel for exterior
- Foam-insulated door for rigidity and long life
- Plastic water tank easy for maintenance
- Observation Window with frost free function
- High performance refrigeration system
- Easy user interface for TEMI-880 PLC controller
- One 100mm cable port/ Customer specified
- One shelve, 10 Kg loading & 4 casters included
- Van Type Sirocco,L134,Fan
- PID controlled-Stainless Steel Humidifier
- DuPont R-404A [No Fluorine] Refrigerant / 23 for below -40 °C
- USB port for data output
- Anti-explosive interior lamps
- Data logging chart recorders, paperless recorders stored data in
the PLC.
Performance indicators
Temperature Range RT + 10 ℃ ~ 100 ℃ Humidity 80 ~ 98% R · H
fluctuation / uniformity ≤ ± 0.5 ℃ / ± 2 ℃ temperature deviation
+2%, - 3% R · H Heating time of about 20min at room temperature ~
100 ℃ temperature control ± 1 ℃ ± 2%
Control System
Imported microcomputer temperature controller wet integrated
controller (display directly percent humidity).
Accuracy range setting accuracy: temperature ± 0.1 ℃, humidity ±
0.1% R · H, indicating accuracy: temperature ± 0.1 ℃, temperature ±
0.1% R · H temperature and humidity sensors platinum platinum
resistance · PT100Ω.
Heating system is completely independent system, electric heating
nichrome heater.
Isolated external humidification systems, stainless steel boiler
type shallow surface evaporative humidifier.
Circulatory system temperature low noise air conditioning motors,
leafy centrifugal wind wheel.
Heating system
Far-infrared heating using nickel-chromium alloy heating wire
heating speed;
High temperature, low temperature completely independent systems;
Temperature control P · I · D + S · S · R system with channel
coordination control;
Temperature control the output power by the microcomputer calculus,
to achieve high accuracy and high efficiency power efficiency.
Cooling System
To ensure the chamber of cooling rate and minimum temperature
requirements, the chamber of the refrigeration system cascade
refrigeration system consisting of imported compressor, the
refrigeration system has a reasonable match, high reliability and
easy maintenance.
Refrigeration works: a refrigeration cycle are used against the
card if the cycle, which consists of two isothermal and two
adiabatic processes, whose process is as follows: a refrigerant
through the compressor adiabatic compression to a higher pressure,
the power consumption of the exhaust gas temperature, after the
refrigerant through the condenser isothermally in and around medium
heat exchange medium heat to four weeks. After the refrigerant
flows through the shutoff valve adiabatic expansion work, when the
refrigerant temperature decreases. Finally, the refrigerant passes
through the evaporator isothermal heat from high temperature
object, the object to be cooled so that the temperature is lowered.
This loop again and again to achieve the purpose of cooling.
4. Professional Stability High Low Temperature and Humidity Test
Machine view:
(Advanced refrigeration design is especially compact for HD-Series
Chambers)