Gustav Elevator Rope Low-Rotation Rope With Rotation Resistant The electric hoist and crane ropeThe PAWO 367 SE is a low-rotation rope with 126 supporting wires in
the outer strands and is mainly used as electric hoist and crane
rope. Properties
- rotation resistant
- long life
- strong
Technical data36 x 7 Spiral round strand with IWRC, regular laynominal rope dia. [mm] | calculated mass [kg/m] | 1770 N/mm2 min. break. load [kN] | 1960 N/mm2 min. break. load [kN] | 2160 N/mm2 min. break. load [kN] |
---|
18 | 1,3 | 189,07 | 209,37 | 230,73 | 19 | 1,45 | 214,65 | 237,69 | 261,95 | 20 | 1,6 | 239,69 | 265,42 | 292,51 | 21 | 1,77 | 258 | 285,69 | 314,85 | 22 | 1,94 | 284,73 | 315,3 | 347,47 | 24 | 2,31 | 334,26 | 370,14 | 407,91 | 25 | 2,51 | 362,8 | 401,74 | 442,74 | 26 | 2,71 | 391,61 | 433,65 | 477,9 | 28 | 3,14 | 458,89 | 508,15 | 560,01 | | | | | |
FAQ 1. Are the elevator wire ropes durable? The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time. 2. Is it dangerous for power failure suddenly during the elevator
running? If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating. 3. Will us be hurt when it closed suddenly? In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here. 4. How the elevator running? Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail. 5. Is the escalator installation complicated? We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning. 6. Do you have any cerifications? Yes, we do with ISO9001 / CCC / CE Certificates for u.
|