PAWO F10 Elevators Gustav Wolf Wire Rope With An Increased Bending
Resistance Special full steel rope with 9 outer strandsOur specially developed PAWO F10 is for the most demanding elevator
installations. The rope´s 9 strand construction allows a tight fit
of the rope in the groove. Thus, this rope offers an extremely long service life, combined
with an increased bending resistance. The compact structure of the
core offers additional metallic cross-section. Properties:
- high rise
- high number of bending cycles
- heavy usage
- low stretch
- long service life
Construction: full steel rope with 9 strands, regular lay, Technical terms of delivery to DIN EN 12385, ISO 4344 load bearing wires in the outer strands: < 12 mm = 117 > 12 mm = 144 tensile grade 1570 N/mm2, steel wire bright or galvanized Properties - Low and mid-rise
- small to intermediate number of bending cycles
- normal to heavy usage levels
- wear-resistant
- low elongation
- extended service life
Construction: 8 x 19 Seale with steel-reinforced fiber core,
regular lay, Technical terms of delivery to DIN EN 12385, ISO 4344 Load-bearing wires in the outer strands: 152 Tensile grade 1570
N/mm², steel wire bright or galvanized rope-Ø (permissible tolerance) | |
---|
no load: | with load (10% of Fmin): | max. 3% < 10 mm | min. -1% <= 10 mm | max. 2% > 10 mm | min. -1% > 10 mm |
rope diameter(mm) | calculated mass (kg/m) | min. breaking load (kN) | part-no. |
---|
8 | 0,270 | 43,2 | 721208032 | 9 | 0,340 | 54,8 | 721209032 | 10 | 0,420 | 67,2 | 721210032 | 11 | 0,503 | 80,2 | 721211032 | 12 | 0,600 | 95,6 | 721212032 | 13 | 0,707 | 113,4 | 721213032 | 14 | 0,850 | 135,7 | 721214032 | 15 | 0,950 | 152,8 | 721215032 | 16** | 1,080 | 174 | 721216032 | 18* | 1,410 | 219,7 | 721218032 | 19*** | 1,510 | 244,9 | 721219032 | 20* | 1,700 | 272,5 | 721220032 | | | | | 9,5(3/8") | 0,380 | 60,5 | 721209530 | 12,7(1/2") | 0,680 | 109,5 | 721212730 | 17,5(11/16") | 1,300 | 208 | 721217530 |
FAQ 1. Are the elevator wire ropes durable? The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time. 2. Is it dangerous for power failure suddenly during the elevator
running? If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating. 3. Will us be hurt when it closed suddenly? In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here. 4. How the elevator running? Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail. 5. Is the escalator installation complicated? We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning. 6. Do you have any cerifications? Yes, we do with ISO9001 / CCC / CE Certificates for u.
|