LSZH compound for Power Cable |
Code.No | Application | Advantage |
ZC-1901 | Sheath of power cable, control cable, marine cables etc | Meet the standard JB/T10707; heat shock with a load of 7kg; meet
the requirement on 60% light transmittance for cable of reasonable
structure and pass the bundle combustion C category (GB/T18380.35) |
ZC-1901C | Sheath of power cable, control cable, marine cables etc | Meet the standard JB/T10707 and is suitable for high-efficiency
extrusion of various extrusion equipment |
ZC-1901M | Sheath of power cable, control cable, marine cables etc | Meet the requirements of ST8 in GB/T12706 and is suitable for
high-efficiency extrusion of various extrusion equipment |
ZC-1901D | Sheath of high flame retardant power cable, control cable, marine cables etc | Meet the standard GB/T 32129; suitable for cable with high flame
retardant and high transmittance requirements, and meet the
requirement of 60% light transmittance of the reasonable structure
cable and pass the bundled combustion test B category(GB/T18380.34) |
ZC-1902 | Sheath of power cable, control cable, marine cable etc. with high
requirements on flame retardant property | Meet the standard GB/T32129; heat shock with a load of 5kg; meet
the requirement on 60% light transmittance for cable of reasonable
structure and pass the bundle combustion C category (GB/T18380.35) |
ZC-1902-J | Insulation of BV wire, power cord et. with high requirements on
flame retardant property | Meet the standard GB/T32129, Oi ³35, meet the single vertical
combustion and bundle combustion A, B and C category for
thermoplastic building wire |
ZC-1902N | Sheath for power cable, control cable, marine cables etc | Meet the standard GB/T32129; heat shock with a load of 5kg; meet
the requirement on 60% light transmittance for cable of reasonable
structure and pass the bundle combustion C category (GB/T18380.35);
resist the mineral oil of 902# under 70℃ for 4h with the variation
ratio of ±40% |
ZC-1903 | Oxygen barrier material for power cable and control cable | power cable with higher requirement on flame retardant property;
good result for flame retardant and crust |
ZC-1903B | Oxygen barrier material for B1 power cable and control cable | Inner sheath of power cable with higher requirement on flame
retardant property; excellent result for flame retardant and crust;
not easy to expand |
ZC-1905 | Branch cable | Meet the requirements of standard JB/T10636-2006--Appendix B, Oi
³25 |
ZC-1907 | Sheath of power cable, control cable, marine cable etc. with high
requirements on flame retardant property | Meet the standard GB/T32129; cable with higher requirement on flame
retardant and light transmittance property; meet the requirement on
60% light transmittance for cable of reasonable structure and pass
the bundle combustion A and B category (GB/T18380.33-34) |
ZC-1902K | Sheath of power cable, control cable, marine cable etc. with high
requirements on transmittance property | Meet the standard GB/T32129; cable with higher requirement on flame
retardant and light transmittance property; pass the bundle
combustion A for single-sheath power cable and bundle combustion A,
B, C category for control cable |
ZC-1906 | Sheath for B1 power cable and control cable | Meet the standard GB/T32129; meet the requirement on 60% light
transmittance for cable of reasonable structure and pass the bundle
combustion B1 category (GB31247) |
ZC-1906A | Sheath for B1 power cable and control cable | Meet the standard GB/T32129; meet the requirement on 60% light
transmittance for single-sheath cable and pass the bundle
combustion B1 category (GB31247) |