China Tripod Turnstile Gate manufacturer
SHENZHEN SINOMATIC TECHNOLOGY CO., LIMITED
MORE SINOMATIC, MORE SECURITY
10
Home > Products > Vehicle Detector Sensor >

170kHz Single Channel Loop Detector 10ms Automatic Calibration Time

Browse Categories

SHENZHEN SINOMATIC TECHNOLOGY CO., LIMITED

City: shenzhen

Province/State:guangdong

Country/Region:china

Tel:86

Contact Person:
Mr.Manfrid Lee
View Contact Details

170kHz Single Channel Loop Detector 10ms Automatic Calibration Time

Brand Name SINOMATIC
Model Number PD-132
Certification CE/ ISO
Place of Origin Shenzhen, China.
Minimum Order Quantity Sample order accepted
Price negotiable
Payment Terms T/T, L/C, D/A, D/P, Western Union, MoneyGram
Supply Ability 3,0000pcs per month
Delivery Time 2-5 working days after payment received
Packaging Details Carton/Plywood box/Pallet
Model PD132
Voltage 220V, 110V, 24V, 12V
Operating temperature -30 degree to 70 degree
Package Carton
Automatic calibration time 2s to 5s
Name Single Channel Loop Detector
Detailed Product Description

PD132 DC 24V 2s To 5s Automatic Calibration Time Single Channel Vehicle Loop Detector

 

Product description

 

PD132 single loop detector is used for wherever vehicles have to be detected , for example for monitoring and

safe-guarding access ways or for counting vehicles. The output signal can be used for controlling door and gate

drive mechanisms, operating barriers, controlling traffic light systems or activating card dispensers in parking lots .

 

PD132 has two-way output relays , one is unlimited output when the loop is temporarily covered , while the other

is multi-mode that can be set by users .

 

PRODUCT APPLICATIONS

 

Automatic Gate
Traffic Light System
Gate Drive Mechanisms
Operating Barriers
Parking Guidance System
Activating Card Dispensers in Parking Lots

 

PRODUCT TECHNICIAL SPECIFICATIONS

 

Supply voltage230VAC , 115V AC, 12V DC, 24V DC( See the label on the detector)
Voltage tolerance AC+10% / -15%
Voltage tolerance DC±15%
Power Consumption4.5VA
Output relays240V/5A
Operating temperature-20°C to +65°C
Storage temperature-40°C to +85°C
Frequency range20kHz to 170kHz
Reaction time10ms
Signal holding timeUnlimited / limited when loop is permanently covered 10 minutes
SensitivityAdjustable in 4 increments
Loop inductanceTotal loop plus connection wiring:50μH to 1000μH.
Ideal is 100μH to 300μH
Loop connection wiringMaximum length 20 meters, twisted at least 20 times per meter
Size of Housing78x40x108 mm (L x W x H)

 

 

 

Main Features

 

1) Reset Switch : The reset switch enables the detector to be manually reset during

commissioning and testing . This results in the detector re-tuning the sensing loop and

becoming ready for vehicle detection ;

 

2) Selectable Pulse Time : This feature sets the length of time that the pulse relay will be

energized for 1 Second or 0.5 Seconds ;

 

3) Pulse Relay Selection : The Pulse Relay may be configured to energize on detection of a

vehicle or when the vehicle leaves the loop ;

 

4) Sensitivity Boost : This feature sets the undetect level to maximum sensitivity and is used

to prevent loss of detection of high-bed vehicles ;

 

5) Switch Selectable Sensibility : 4 sensitivity setting are available on the switches to allow

flexibility in configuration ;

 

6) Switch Selectable Frequency : 4 frequency settings are available to prevent cross-talk

between adjacent loops ;

 

7) Filter Option : This option is used to provide a delay between detection of the vehicle and

switchiing of the output relay . This relay is normally used to prevent false detection of

small or fast moving objects ;

 

8) Permanent Presence Option : This feature ensure detection of the vehicle will be maintained

when the vehicle is parked over the loop for extended periods .

 

PRODUCT INSTALLATION

 

The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation

location must choose to stay away from the heat source, it around other devices must maintain a distance of at least

10mm (mustn’t fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful

inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install

methods (details as “Loop installation guide”).

 

Work indicator

 

Detector will enter into the self-calibration condition with the green LED flash, red LED extinguish once on power,

this procession will last 1 second. .the vehicle should not on the loops within the self-calibration. The green LED will

not flash, he red LED extinguish after self-calibration. When the vehicle past over the loop ,the red LED on.

 

Operation and Indication

 

While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds,

then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault

is self-healing the detector will continue to operate. The green channel LED will also glow whenever a vehicle is

detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the

unit is powered.

 

Frequency

 

To eliminate interference of two neighbouring wire loops or loop detectors, the frequency can be altered.

Sensitivity

 

The sensitivity of the detector allows the detector to be selective as to the change of inductance necessary to produce

an output. There are four sensitivity selections and are set as follows by DIP3 and DIP4 Switch.

Product Tags: 170kHz Single Channel Loop Detector   DC24V Single Channel Loop Detector   Automatic Calibration Vehicle Metal Detector  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: SHENZHEN SINOMATIC TECHNOLOGY CO., LIMITED
Subject:
Message:
Characters Remaining: (80/3000)