HXPC-100B1X Radiographic Detecting Pipeline Welds X-ray Pipeline
Crawler Features - Unlike controlling the equipments via listening to sounds,
manipulators can control the exposure moments and manipulate the
X-ray pipeline crawlers to move forward or backward via magnetic
orientator.
- Magnetic locators have the following features: higher positional
accuracy, strong penetrability, and higher stability. The magnetic
transmitter is equipped with electric display.
- The X-ray pipeline crawlers can display the voltage of the battery
and directly judge the use of the battery.
- The X-ray pipeline crawlers’ software is written with fault codes.
Please refer to the fault code table to detect equipment
malfunctions.
- The X-ray pipeline crawler has smaller size, lighter weight, and it
is more convenient for transportation and operation.
- Equipped with all kinds of protection functions, including
encountering water protection, 20 minutes no one operation
protection, etc.
- Users can replace the controller, the circuit board, and other
parts easily due to modular design.
- The generator adopts a small 2005 portable circumferential cone
target flaw detector: the controller and the head of the machine
are separated, which is more convenient for users to replace,
debug, and test. If the generator is equipped with the controller,
the whole set can be used as a portable flaw detector.
- The crawler is equipped with false load, and the time is set for
0.2 minute. The crawler can simulate the real load working, such as
exposure, moving forward or backward without connecting pipe head.
This function enable users to learn how to locate and determine the
fault.
- The lengthening shaft adopts keyless connection, which is more
convenient to replace.
- The magnetic receiver has 8 gear ranges, which satisfy the
requirements of different diameters.
Parameters Crawler model | HXPC-100B1X | Applicable pipe inner diameter | Φ400-1100 mm | Cleaning pipe optimum climbing slope | 12° | controlling method | Magnetic positioning | output voltage | 150-250 kv | Output current | 3 mA | exposure time | 0-3 min | positioning accuracy | ±5 mm | Travel speed | 12 m/min | Battery voltage / capacity | 108V/7AH,108V/12AH | Non-exposure walking distance | 2000m | Applicable wall thickness | ≤34mm | Crawler Total length mm | 2100(car body1100mmshoe550mm) | Driving mode | Single drive | focal spot size | 2.0*2.0 | X-ray radiation angle | 360°*30° | Operating ambient temperature | -20°C to +75°C | storage temperature | 0°C to +60°C | Applicable environmental humidity | ≤85% | Battery box weight | 21Kg,42Kg | Generator weight | 13kg | Climbing weight | 30kg | The turning radius of the crawler | >7D | Generator type | HUATEC XXGH-2505 ceramic tube |
|