Field Strength Meter Magnetic Particle Testing Equipment High Accuracy
|
Digital Tesla Meter Gauss Meter Field Strength Meter for Magnetic
Particle Inspection HGS-10A Principle of Hall Effect
When placing the semiconductor carrying current in the magnetic field axial to the current direction, the semiconductor will generate transverse galvanomagnetic phenomenon, namely generate electromotive force in the direction axial to the magnetic field and current, which is Hall Effect. Hall Effect can be explained with classical galvanomagnetic theory. Generally, Hall voltage UH is expressed as: UH=RHIB0/d= RHIIB0 Of which: d—the thickness of the Hall device RH—Hall constant RHI=RH/d—Constant of the Hall device I—Current intensity passing through the Hall device B0—The measured magnetic induction intensity It can be seen from the formula: For a certain Hall device, the magnetic field B0 can be indirectly measured through measuring the Hall device if only the passing current I is constant. Since it can count continuously and linearly with simple method and long service life when measuring the magnetic field with Hall Effect and can measure the magnetic field of small space and small gap, Hall Effect Method has become one important method among magnetic field measurements
HGS-10C is the first hand-held type Gauss meter of HGS series Gauss meters. This instrument is the magnetic field measuring instrument specially designed for field measurement. Its design concept of lightness, practicality and portability has been determined at the beginning of instrument design and its unique design of micro power consumption allows its battery life to be greatly improved.
III Instrument operating instruction Place the Hall probe in the standard magnetic field and adjust the “Calibration” ⑦potentiometer with small slotted screwdriver till the instrument reading is consistent with the numerical value of the standard magnetic field. Generally, it will be required to calibrate the instrument only after the Hall probe is replaced. Main Technical Parameters Rang: 0~20000GS Accuracy: ±5% Sensitivity: 0.1GS, 1GS Temperature of environment: 5℃-40℃ Relative humidity: 20%-80%(no condensation) Power Supply: Battery 9V, constant DC power Dimension: 150mm×70mm×30mm Weight: N.W: 500g G.W:900g Display: 4½ LCD
Shape of the device:
Standard delivery Main unit Transverse fiber probe Instruction manual Calibration certificate Carrying case Power adaptor
Optional accessories Lognitudinal probe Transverse metal probe
|
Product Tags: mpi testing machine magnetic particle test equipment magnetic particle inspection equipment |
![]() |
DC AC Tasla Meter Digital Gauss Meter For Inspecting Checking Flux Density |
![]() |
High Sensitivity Gauss Tesla Meter Measure Dc Or Ac Magnetic Field And Flux Density |
![]() |
UV-A 365&420 Single Channel uv irradiance meter Ultraviolet Radiometer |
![]() |
Accuracy Uv Radiometer Measurement Of Light Sources And Irradiation Systems |
![]() |
AC200v Coil Flaw Magnetic Crack Detector Magnaflux |
![]() |
Magnetic Particle Flaw Detector Accessories Dead Weight Test Block With Hole |