HCDX-3000SJ Fluorescence Magnetic Particle Testing Machine AC 16000 ~ 0AT
|
HCDX-3000SJ AC fluorescence magnetic test booth
Technical features
Magnetizing current:
Circumferential magnetizing current (AC): 0-3000A(virtual value)adjustable continuously, phase controlled circuit Breaker Vertical magnetizing current(AC): 0-16000AT(virtual value)adjustable continuously, phase controlled circuit Breaker Magnezing method: Circumferential, Vertical,resultant magnetization Coil inner diamter Φ500mm(one piece) Electrode Pole distance 0-1000mm adjustable Clamp travel route 40 mm(single phase) Electrode Pole rotating speed: 10turns/minute Clamp type: Air power control or electric control Demagnezing method AC attenuation demagnezing Demagnezing magnetomotive: AC 16000~0AT Remanence ≤0.2 mT UV strength: ≥ 2000μW/cm2 (distance to UV light 380 mm) Air power pressure: 0.4~0.8 Mpa (offered by customer) Power: Three phase four line AC 380V 50Hz 150A Outside size 1800(L)×800(W)×1900(H) Total weight: about 1.0T Duty cycle: ≥25%
Configuration
Note:“●” standard configuration,“○” optional
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: magnetic particle inspection equipment mpi testing machine |
![]() |
DC AC Tasla Meter Digital Gauss Meter For Inspecting Checking Flux Density |
![]() |
High Sensitivity Gauss Tesla Meter Measure Dc Or Ac Magnetic Field And Flux Density |
![]() |
UV-A 365&420 Single Channel uv irradiance meter Ultraviolet Radiometer |
![]() |
Accuracy Uv Radiometer Measurement Of Light Sources And Irradiation Systems |
![]() |
AC200v Coil Flaw Magnetic Crack Detector Magnaflux |
![]() |
Magnetic Particle Flaw Detector Accessories Dead Weight Test Block With Hole |