Wired Room Non Programmable Thermostat With Backlight ST23 / 2301
|
Heating / Cooling Non-Programmable, with backlightProduct Description
Specification
1.Programmability: Non-programmable 2.Display Temperature Range:0°C~40°C (in 0.1°C increments) 3.Adjustable Temperature Range:5°C~35°C (in 0.5°C increments) 4.Temperature measurement accuracy: ±1°C (at 20°C) 5.Defrosting Temperature: +7°C 6.Power source: 2x AAA 1.5V LITHIUM BATTERY 7.Load Rating: 6(2)A, 230V 8.Low Battery Indicator: Display ““ when battery is less than 2.7V 9.Standby current:5uA, Lighting current ≤ 4.2mA 10.Backlight colour: Orange / Blue 11.Dimensions: 118 x 80 x 26 mm
Relay Wiring
Heating: connect the two connection wires of the device to be controlled to terminals No. 3 (NO) and No. 2 (COM), i.e. to the normally open terminals of the relay Cooling: the two connection wires of the cooling equipment should be connected to terminals No. 2 (COM) and No. 1 (NC), i.e. to the normally closed terminals of the relay.
• To prevent electric shock, replace the inner cover removed for the connection of wires after the assembling process has been completed.
The device must be installed and connected by a qualified professional. Always follow the manufacturer's instructions when connecting the thermostat to any heating or cooling appliance.
The voltage appearing at terminal No. 1, No. 2 or No. 3 depends only on the system being controlled, therefore the dimensions of the wire are determined by the type of the device to be controlled. The length of the wire is of no significance.
LCD Display
Running Mode Switch by press in different mode: HEAT (Heating): adjust the temperature by press + or - COOL (Cooling): adjust the temperature by press + or - OFF (Frost Protection): it will start heating when the room temperature is under 7°C
Settings
1. HEAT SWING: Hold + and - under the “HEAT”mode for 3 secs to enter the interface of Swing setting (in 0.2~2); Press + or - to set the desired value, then press to confirm. 2. COOL SWING: Hold + and - under the “COOL”mode for 3 secs to enter the interface of Swing setting (in 0.2~2); Press + or - to set the desired value, then press to confirm.
3. Calibrate the temperature: Hold + and - under the “OFF”mode for 3 secs to enter the interface of temperature
|
Product Tags: Wired Non Programmable Thermostat LITHIUM BATTERY Non Programmable Thermostat 1.5V LITHIUM BATTERY Wired Room Thermostat |
![]() |
Riseem 230V LCD Digital Display Electronic Home Thermostat Non-Programmable With NTC Sensor |
![]() |
Riseem Smart Wired Room Programmable Thermostat For Gas Boiler 5-35℃ LCD Digital Display |
![]() |
Riseem ABS Wired Room Home Programmable Boiler Thermostat 50Hz HVAC Temperature Control |
![]() |
Riseem ABS Gas Boiler Wired Digital Room Thermostat Programmable For HVAC System |
![]() |
Riseem LCD Non Programmable Floor Heating Thermostats 6A With Smart NTC Sensor |
![]() |
Riseem ISO Gas Boiler Room Non-programmable Thermostat For Floor Heating System 230V |