Walk In Temperature Simulation Constant Temperature And Humidity Control Chamber

Brand Name ASLI
Model Number THR-Volume
Certification CE, ISO , SGS
Place of Origin China
Minimum Order Quantity 1 Set
Price Negotiate
Payment Terms T/T, Western Union
Supply Ability 100 sets per year
Delivery Time 20 workdays
Packaging Details wooden case
internal size custom size
temperature range -60~150C
humidity range 10%R.H.~98%R.H.
test hole Dia.50mm
communication interface RS232, RS485
application AUTO parts, car door
Detailed Product Description

=click for details>>>>>>> Walk in Temperature Humidity Room THR-Volume.pdf

 

 

Programmable large laboratory test equipment walk in temperature climatic Test Chamber is mainly composed of a control system, a refrigeration system, a test library body, a circulation fan, a heater, and a humidifier. Provide large-scale parts, semi-finished products, finished products, temperature and humidity environment testing, such as: computer terminals, auto parts, complete vehicles, military products.

 

 

Parameter:

 

ModelTHR-volume (low-temperature options : A ~ F)
Inner Dimensions(cm)Customers designated space size and design
Temperature RangeLow Temperature(A:25°C B:0°C C:-20°C D:-40°C E:-60°C F:-70°C) High Temperature 80°C (80°C ~150°C is optional)
Humidity Range20%~98%R.H.(10%-98% R.H. / 5%-98% R.H ,is a special optional condition, need dehumidifier)

Indication Resolution/Distribution

Uniformity of Temperature & Humidity

0.1°C; 0.1% R.H/±2.5°C; ±3.5% R.H.

Control Accuracy of

Temperature and Humidity

±0.5°C; ±2.5% R.H.

Temperature Rising/Falling

Velocity

Temperature rising approx. 0.1~3.0°C/min

temperature falling approx. 0.1~1.0°C/min;

( The Falling Velocity Min.1.0°C /min is a optional)

Cooling SystemWater cooled
Protection DevicesFuse-free switch, overloading protection switch for compressor,high and low voltage coolant protection switch, over-humidity & over-temperature protection switch, fuses, fault warning system, water short storage warning protection
Optional AccessoriesSlope for cart , Recorder, Water Purifier, Dehumidifier
CompressorFrench Tecumseh Brand, Germany Bizer Brand
PowerAC 380 V(±10%),50/60HZ ,3 phase 5 Lines

 

 

Walk in Temperature Simulation Constant Temperature and Humidity Control Chamber Standards
 

1.GB2423.1-2008/1EC6008-2-1-2007 Low temperature test method

2.GB/T2423.2-2008 High temperature test method

3.GJB150.3A-2009 High temperature test method

4.GJB150.4A-2009 Low temperature test method

5.GB2423.22-2008 Temperature change rate test method

6.GBT2424.5-2006 temperature test box performance confirmation

7.GB/T10586-2008 Low temperature test chamber technical conditions

8.GB/T2423.3-2008 (1EC68-2-3) Constant damp heat test method

9.GJB150.9A-2009 Damp heat test method

10.G/BT2423.4-2008/1EC6008-2-30:2005 alternating heat and humidity method

11.GB/T5170.18-2005 Test equipment basic parameters verification method

12.GB/T10586-2006 Damp heat test chamber technical conditions

13.GBT2424.6-2006 Temperature and humidity test chamber performance confirmation

14.GBT2424.7-2006 (with load) temperature test chamber measurement.

 

 

Characteristics
 

1. Appearance can be matched with different colors according to the interior design or all stainless steel design. The indoor space is made of SUS304# stainless steel.

2. Rectangular laminated glass viewing window, which can be used for observation in the test. The window has a sweat-proof electric heater device to prevent condensation of water and moisture.

3. Indoor installation of explosion-proof lamps, the test condition of the product can be clearly observed during the test, and the anti-slip aluminum plate is installed at the bottom of the test room.

4. The door is insulated and sealed to effectively isolate the internal temperature leakage.

5. With pure water filter unit directly for tap water use, no need to manually add water, easy to use

6. The refrigeration dehumidification system adopts imported brand compressors, which have the advantages of energy saving, low noise, low energy consumption and stable performance, and adopt environmentally friendly refrigerants (R23, R404a).

7. The controller adopts the imported LCD display screen, which can display the measured value, set value, time, etc. at the same time.

8. The controller has multi-stage program editing and temperature, humidity can be done quickly (QUICK) or slope (SLOPE) control.

 

 

Please feel free to contact us if any needs about Walk in Temperature Simulation Constant Temperature and Humidity Control Chamber.

Product Tags: stability test chamber   walk in environmental chamber  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: ASLi (CHINA) TEST EQUIPMENT CO., LTD
Subject:
Message:
Characters Remaining: (80/3000)