Model | THV-408(A~F) | THV-1000(A~F) | THV-1500(A~F) |
Internal Dimension W×H×D(mm) | 600×850×800 | 1000×1000×1000 | 1500×1500×1500 |
External dimension W×H×D (mm) | 850×1950×2100 | 1300×2200×2400 | 1800×2400×3000 |
Temperature Range | Low temperature: (A:25°C; B:0°C; C:-20°C; D: -40°C; E: -60°C;
F:-70°C) High temperature:100°C(150°C) |
Humidity Range | 20%~98%R.H. (10%-98% R.H. / 5%-98% R.H. is optional , need Dehumidifier) |
Indication Resolution /Distribution Uniformity of Temperature and Humidity | 0.1°C; 0.1% R.H/±2.0°C; ±3.0% R.H. |
Control Accuracy of Temperature and Humidity | ±0.5°C; ±2.5% R.H. |
Temperature Rising/ Falling Velocity | Rising velocity is approx. 0.1~3.0°C/min ; Falling velocity is approx. 0.1~1.5°C/min; ( >1.5°C/min is
optional ) |
Interior and Exterior Material | Interior material is SUS 304# stainless steel, Exterior is stainless steel or SEE cold-rolled steel with paint
coated. |
Insulation Material | Resistant to high temperature, high density, formate chlorine,
ethyl acetum foam insulation materials |
Cooling System | Wind cooled or water cooled; single segment compressor for -40°C, double segment compressor for
-70°C |
Protection Devices | Fuse-free switch, overloading protection switch for compressor,
high and low voltage coolant protection switch, over-humidity and over-temperature
protection switch, fuses, fault warning system, water short storage warning protection |
Optional Accessories | Inner door with operation hole(Optional) , Recorder(optional),
Water Purifier, Dehumidifier |
Power | AC380 |