Single Point Load Cell IN-1042
Aluminum Load Cell
Creep precision up to 0.005%
Interchangeable with Rice LAKE 1042
LOAD CELL PARAMETER | UNIT | TECHNICAL DATA |
Rated capacity (Emax) | kg | 3/6/10/15/20/25/30/35/40/50/60/100 |
Huazhun Grade | | A | B |
Sensitivity | mV/V | 2.0+- 10% |
Platform size | mm | 250 350(300 380) |
Zero balance | mV/V | 0.02 |
Creep over 30min | % | 0.008 | 0.012 |
Temperature effect on zero | %/ | 0.004 |
Temperature effect on output | %/ | 0.0014 |
Hysteresis | % | 0.01 | 0.015 |
Linearity deviation | % | 0.01 | 0.015 |
Repeatability | % | 0.01 | 0.015 |
Nominal temperature range |
| -10 to +40 |
Service temperature range |
| -30 to +70 |
Limit load | % of R.C. | 150 |
Break load | % of R.C. | 200 |
Nominal excitation | V | 5~12 |
Max. excitation | V | 15 |
Input impedance |
| 405+- 10 |
Output impedance |
| 350+- 3 |
Insulation resistance | M | >2000 |
Cable length | M | 0.5 |
Cable type | | 4 conductors, Braid Shielded, Black PVC Jacket |
Color code | | +Exc -Red, +Sig-Grn, -Exc-Blk, -Sig- Wht |
Construction | | Aluminum |
Protection class to IEC529 | | IP 66 |