PO Sheath BS8519 Multicore Insulated Cable With Stranded Conductor
|
|
Multi Cores Cu conductor Mica Tape Wrapping XLPE Insulated Fire Resistant Cable BS8519
Rated Voltage: 0.6/1KV Range of Nominal cross section: 1 core: 1.5 mm2 ~ 300 mm2 Multi core: 0.75 mm2 ~ 35 mm2
Our fire performance cables are specifically designed for augmented fire resistance in applications including the delivery of power and auxiliary control in fire alarm systems, voice alarm systems, and emergency lighting systems including those applications designed to meet BS5266. These cables will form part of the requirements of BS8519 for the installation of fire-resistant power and control cable systems for life safety and fire-fighting applications.
Applications
These cables are installed to supply power to building essential services including fire alarms, sprinkler control system, emergency and evacuation lighting and smoke control systems, such as high rise buildings and apartments, airports, shopping centres, cinemas and road and rail tunnels And tall building, Hospital, Theatre, Power station, Metro
Tunnel or Petrochemical Industry or other special place required
for low smoke , zero halogen clean and safe cable.
Technical data
Max. Conductor Temp.: normal (90°C), short circuit no more than 5 s (the highest temperature of conductor shall no more than 250°C ) Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0°C Min. Bending Radius: single core cable 20(d+D)±5% Multi-core cable 15(d+D)±5%
Certificates
CE, RoHS, CCC, KEMA and more others at request
Specifications
Operating characteristics
1. Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C; 2. Installing temperature of cable should not be less than 0°C; 3. Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec; 4. Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable) 5. Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: BS8519 multicore insulated cable PO sheath multicore power cable BS8519 multicore electrical cable | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
CU 5C FRC LSZH Power Cable Five Core Stranded Class 2 |
|
0.6 / 1kV CU / XLPE LOZH Fire Resistant Cable Indoor / Outdoor Electrical Cable |
|
Single Core Flame Resistant Cable 1.5 - 800sqmm 0.6 / 1kv Iec 60331 60502 |
|
0.6/1kV Single Core Fire Retardant Power Cable 1.5sqmm ~ 800sqmm IEC 60331 |
|
Copper Conductor 4 Core Fire Resistant Cable 1.5 sqmm ~ 800 sqmm |
|
Transmit Distribute Power Fire Resistant Cable Indoor / Outdoor CE KEMA Certification |