750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB
|
|
1, Engine Make & Model:
Perkins 4006TAG2A
750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB
Ratings at 0.8 power factor.
P730P1 / P800E1
Engine Technical Data Physical Data
Manufacturer: Perkins Model: 4006TAG2A No. of Cylinders/Alignment: 6 / In Line Cycle: 4 Stroke Induction: Turbocharged Air To Air Charge Cooled Cooling Method: Water Governing Type: Electronic Governing Class: ISO 8528 G2 Compression Ratio: 13.6:1 Displacement: l (cu.in) 22.9 (1398.7) Bore/Stroke: mm (in) 160.0 (6.3)/190.0 (7.5) Moment of Inertia: kg m² (lb. in²) 10.61 (36256) Engine Electrical System: -Voltage/Ground: 24/Negative -Battery Charger Amps: 40 Weight: kg (lb) - Dry: 2524 (5564) - Wet: 2663 (5871)
Air System
Air Filter Type: Replaceable Element Combustion Air Flow: m³/min (cfm) -Standby: 71.0 (2507) 73.0 (2578) -Prime: 64.0 (2260) 65.0 (2295) Max. Combustion Air Intake Restriction: kPa (in H2O) 3.7 (14.9) 3.7 (14.9) Radiator Cooling Air Flow: m³/min (cfm) 1134.0 (40047) 1326.0 (46827) External Restriction to Cooling Air Flow: Pa (in H2O) 250 (1.0) 250 (1.0) Cooling System 50 Hz 60 Hz Cooling System Capacity: l (US gal) 105.0 (27.7) 105.0 (27.7) Water Pump Type: Centrifugal Heat Rejected to Water & Lube Oil: kW (Btu/min) -Standby: 230.0 (13080) 243.0 (13819) -Prime: 191.0 (10862) 200.0 (11374) Heat Radiation to Room: kW (Btu/min) -Standby: 88.7 (5044) 98.9 (5624) -Prime: 83.7 (4760) 93.9 (5340) Radiator Fan Load: kW (hp) 26.0 (34.9) 44.0 (59.0) Cooling system designed to operate in ambient conditions up to 50°C (122°F). Contact your local FG Wilson dealer for power ratings at specific site conditions. Performance 50 Hz 60 Hz
Engine Speed: RPM 1500 1800 Gross Engine Power: kW (hp) -Standby: 711.0 (953.0) 759.0 (1018.0) -Prime: 646.0 (866.0) 684.0 (917.0) BMEP: kPa (psi) -Standby: 2481.0 (359.9) 2208.0 (320.2) -Prime: 2255.0 (327.0) 1989.0 (288.5) Regenerative Power: kW 70.0 75.0
LubriCAT-parts-partsion System Oil Filter Type: Spin-On, Full Flow Total Oil Capacity l (US gal): 123.0 (32.5) Oil Pan l (US gal): 113.4 (30.0) Oil Type: API CG4 15W-40 Cooling Method: Water
Exhaust System 50 Hz 60 Hz Silencer Type: Level 1 Silencer Model & Qty: SD250 (1) Pressure Drop Across Silencer System: kPa (in Hg) 1.20 (0.354) 0.22 (0.065) Silencer Noise Reduction Level: dB 20 16 Max. Allowable Back Pressure: kPa (in. Hg) 6.0 (1.8) 6.0 (1.8) Exhaust Gas Flow: m³/min (cfm) -Standby: 180.0 (6357) 190.0 (6710) -Prime: 180.0 (6357) 190.0 (6710) Exhaust Gas Temperature: °C (°F) m³/min (cfm) -Standby: 430 (806) 430 (806) -Prime: 430 (806) 430 (806)
Fuel System Fuel Filter Type: Replaceable Element Recommended Fuel: Class A2 Diesel Fuel Consumption: l/hr (US gal/hr) 110% 100% 75% 50% Load Load Load Load P730P1 50 Hz 164.0 (43.3) 149.8 (39.6) 114.8 (30.3) 81.6 (21.6) 60 Hz 189.1 (50.0) 167.0 (44.1) 124.7 (32.9) 89.9 (23.7) P800E1 50 Hz 163.4 (43.2) 124.7 (32.9) 87.9 (23.2) 60 Hz 189.1 (50.0) 139.9 (37.0) 97.8 (25.8) (based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2) P730P1 / P800E1
Alternator Performance Data
Reactances shown are applicable to prime ratings
** With optional Permanent Magnet generator or AREP excitation.
Alternator Technical Data
P730P1 / P800E1
Technical Data 3 Phase Ratings and Performance at 50 Hz, 1500 RPM 3 Phase Ratings and Performance at 60 Hz, 1800 RPM
Definitions
Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standard Reference Conditions Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Weights and Dimensions
Weights: kg (lb) Dimensions: mm (in
General Data Documents A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.
Generating Set Standards The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.
Warranty All equipment carries full manufacturer's warranty.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: standby diesel generator portable diesel powered generators | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
60KW Perkins Silent Portable Diesel Generator 3kva To 3000kva |
|
50KW Perkins 3 Phase 4 Cylinder Diesel Generator For Fishing Grounds |
|
40KW Trailer Type Perkins Diesel Generator For Transportation Farmland |
|
Perkins 30KW Soundless Diesel Generator For Home Backup Emergency |
|
100KW Water Cooled 4 Stroke Perkins Diesel Generator With Heavy Duty Radiator |
|
Mine Power Generation Noise 95dB Perkins Diesel Generator Sold For Factory |