4 Stroke 80 kW Diesel Generator , JPP100E , 100 kva , 4 Stroke
|
|
1, Generating Set Model: JPP100E
Ratings at 0.8 power factor.
P90 / P100E
Engine Technical Data
Physical Data
Manufacturer: Perkins Model: 1006TG1A No. of Cylinders/Alignment: 6 / In Line Cycle: 4 Stroke Induction: Turbocharged Cooling Method: Water Governing Type: Mechanical Governing Class: ISO 8528 G2 Compression Ratio: 16.0:1 Displacement: l (cu.in) 6.0 (365.5) Bore/Stroke: mm (in) 100.0 (3.9)/127.0 (5.0) Moment of Inertia: kg m² (lb. in²) 1.61 (5502) Engine Electrical System: -Voltage/Ground: 12/Negative -Battery Charger Amps: 55 Weight: kg (lb) - Dry: 586 (1292) - Wet: 623 (1373)
Air System
Air Filter Type: Replaceable Element Combustion Air Flow:m³/min (cfm) -Standby: 5.6 (198) 7.9 (279) -Prime: 5.2 (184) 7.5 (265) Max. Combustion Air Intake Restriction: kPa (in H2O) 5.0 (20.1) 5.0 (20.1) Radiator Cooling Air Flow:m³/min (cfm) 192.0 (6780) 244.0 (8617) External Restriction to Cooling Air Flow: Pa (in H2O) 125 (0.5) 125 (0.5)
Cooling System 50 Hz 60 Hz
Cooling System Capacity:l (US gal) 27.7 (7.3) 27.7 (7.3) Water Pump Type: Centrifugal Heat Rejected to Water & Lube Oil: kW (Btu/min) -Standby: 61.4 (3492) 76.4 (4345) -Prime: 54.4 (3094) 69.1 (3930) Heat Radiation to Room:kW (Btu/min) -Standby: 39.9 (2269) 39.7 (2258) -Prime: 32.4 (1843) 31.0 (1763) Radiator Fan Load: kW (hp) 2.8 (3.8) 4.9 (6.6) Cooling system designed to operate in ambient conditions up to 50°C (122°F). Contact your local FG Wilson dealer for power ratings at specific site conditions.
Performance 50 Hz 60 Hz
Engine Speed: RPM 1500 1800 Gross Engine Power: kW (hp)
-Standby: 96.0 (129.0) 113.0 (152.0) -Prime: 87.0 (117.0) 102.7 (138.0) BMEP: kPa (psi) -Standby: 1283.0 (186.1) 1259.0 (182.6) -Prime: 1163.0 (168.7) 1144.0 (165.9) Regenerative Power: kW 12.6 16.2
LubriCAT-parts-partsion System
Oil Filter Type: Spin-On, Full Flow Total Oil Capacity l (US gal): 16.1 (4.3) Oil Pan l (US gal): 13.1 (3.5) Oil Type: AP1CD 15W-40 Cooling Method: Water
Fuel System
Fuel Filter Type: Replaceable Element Recommended Fuel: Class A2 Diesel Fuel Consumption: l/hr (US gal/hr) 110% 100% 75% 50% Load Load Load Load P90 50 Hz 23.1 (6.1) 20.7 (5.5) 15.7 (4.1) 11.1 (2.9)
60 Hz 28.3 (7.5) 26.1 (6.9) 20.0 (5.3) 14.4 (3.8)
P100E 50 Hz 23.1 (6.1) 17.3 (4.6) 12.1 (3.2) 60 Hz 28.3 (7.5) 21.6 (5.7) 15.4 (4.1) (based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)
Exhaust System 50 Hz 60 Hz
Silencer Type: Level 1 Silencer Model & Qty: SD80 (1) Pressure Drop Across Silencer System: kPa (in Hg) 0.00 (0.000) 0.00 (0.000) Silencer Noise Reduction Level: dB 18 18 Max. Allowable Back Pressure: kPa (in. Hg) 6.0 (1.8) 6.0 (1.8) Exhaust Gas Flow: m³/min (cfm) -Standby: 16.8 (593) 22.5 (795) -Prime: 14.9 (526) 20.9 (738) Exhaust Gas Temperature: °C (°F) m³/min (cfm) -Standby: 584 (1083) 569 (1057) -Prime: 546 (1014) 538 (1001) P90 / P100E
Alternator Performance Data
Reactances shown are applicable to prime ratings
** With optional Permanent Magnet generator or AREP excitation.
Alternator Technical Data
P90 / P100E
Technical Data
3 Phase Ratings and Performance at 50 Hz, 1500 RPM 3 Phase Ratings and Performance at 60 Hz, 1800 RPM
Definitions Standby Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standard Reference Conditions
Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Weights and Dimensions
Weights: kg (lb) Dimensions: mm (in)
General Data
Documents
A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets. Generating Set Standards
The equipment meets the following standards:
Warranty
All equipment carries full manufacturer's warranty.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: standby diesel generator diesel generators sets | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Silent Diesel Generator Backup Power Generator Set Supplier |
|
3 Phase Water Cooling Silent Diesel Generator Set 200kva Electric |
|
Open Type Genset Diesel Generator 20kva / 16kw Air Cooled |
|
125kva Silent Diesel Generator Sets Sold For Community Use |
|
Household Power 40kw Genset Diesel Generator With Mute Cover |
|
Cummins Silent Type Diesel Generator Set 100KVA For Farms And Fisheries |